Sharp MX-2310U / MX-3111U (serv.man10) Handy Guide ▷ View online
Firmware Upgrade
25
Document Solutions After Sales Service
Note: Once the machine has entered “service download mode”, the update will
Commence and the progress be displayed
6.
When the firmware upgrade is complete, click Reboot to execute a remote restart
Of the machine
Firmware Upgrade is Complete
Firmware Recovery Procedure
26
Document Solutions After Sales Service
The following five keys are used for executing functions when in the CN Update mode
1.
Insert the USB memory containing the firmware into the USB port
2.
Turn on the power
3.
Check to confirm the machine starts booting (It takes more than
10 seconds to display the menu)
In the event of a power failure during a firmware update or HDD failure, the machine may fail to reboot because of
corrupted firmware. In this case the SD card containing the correct BOOT program will have to be replaced,
firmware will then have to be recovered using the CN method.
corrupted firmware. In this case the SD card containing the correct BOOT program will have to be replaced,
firmware will then have to be recovered using the CN method.
Firmware Recovery Procedure:
To enter the CN firmware recovery method, turn ON the UPDATE DIP-SW on the MFP PWB
OK key
MENU key
BACK key
UP key
DOWN key
Display when Booting is complete
Firmware Recovery Procedure
27
Document Solutions After Sales Service
4.
Select update from USB memory by using the “MENU” and “BACK” keys
5.
Press the “OK” key, the firmware file saved on the USB memory key is retrieved, and the file selection
menu is displayed
6.
Select the target firmware file using the “UP” and “DOWN” keys. When the correct file is displayed select
the “OK” key, the selected firmware file will be read. Once read the update procedure will continue
•
The abbreviated name of the firmware which is under update should appear in the upper right corner of
the display
•
During the update process, the display may flash instantaneously. It is normal operation
7.
Check the update results of all firmware files by using the “UP” and “DOWN” keys
8.
Turn off the power
9.
Turn OFF the UPDATE DIP-SW on the MFP PWB
10.
Turn on the machine ensuring BOOT animation is displayed and the “Copying is enabled” is displayed
Update Successful
Update not Executed
Update Failed
Firmware Recovery is Complete
Firmware and Print Driver Revision
28
Document Solutions After Sales Service
Firmware:
MX2310U/3111U
Firmware
Version
ICU Main
05.00.G1
ICU Boot
01.03.G1
PCU
03.02.G1
SCU
01.07.G1
Inner Finisher
01.04.03
Fax Main
01.01.G1
Desk
02.00.G1
E-Manual
01.80.G1
Watermark Data
01.00.F1
Data Security Kit (MX-FR25U)
04.02.Gc
Print Driver:
Driver
Windows 32bit OS
2008, XP, 2003, Vista, Win 7
Windows 64bit OS
XP, 2003, Vista, 2008, Win 7
SAPL-c
02.00.01.18
02.00.01.18
PCL5e
n/a
n/a
PCL6
03.01.28.19
03.01.28.19
PS
03.01.28.19
03.01.28.19
PPD
1.0.0.3
1.0.0.3
XPS*
01.02.32.01
01.02.32.01
For the latest Firmware and Print Driver version(s), please refer to Sharp Technical Website
www.tradenet.sharp.co.uk/tech
Click on the first or last page to see other MX-2310U / MX-3111U (serv.man10) service manuals if exist.