DOWNLOAD Sharp DM-2000 (serv.man6) Service Manual ↓ Size: 208.81 KB | Pages: 14 in PDF or view online for FREE

Model
DM-2000 (serv.man6)
Pages
14
Size
208.81 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / DM2000 Service Manual-Simulations Flash Rom Version Up Procedure
File
dm-2000-sm6.pdf
Date

Sharp DM-2000 (serv.man6) Service Manual ▷ View online

Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
41
3
Document sensor light
reception level display
Used to display the light reception level and the detection level of the
document sensor. (The sensor level adjusted with SIM 41-2 is displayed.)
42
1
Developing counter clear
Used to clear the Developing counter. 
∗2
43
1
Fusing temperature setting
Used to display the current setting of the fusing temperature at right.
After selecting the fusing temperature with the magnification ratio display
key, press the start key, and the set value is stored. The set range is
155 
∼ 190˚C. Use the magnification ratio key to adjust the value by –5˚C.
180
155 
∼ 190
46
1
Copy density level
adjustment
After completion of warmup, shading is performed and the currently set
copy density level is displayed. For the adjustment procedure, refer to
the previous descriptions.
48
∼ 99
48
1
Main scanning (front/rear)
direction magnification
ratio adjustment
(Copy/FAX/OC-SPF
common)
After completion of warmup, shading is performed and the currently set
main scanning (front/rear) direction magnification ratio adjustment and
the OC mode document center off adjustment are performed. For the
adjustment procedure, refer to the previous descriptions.
58
∼ 99
2
OC mode sub scanning
direction magnification
ratio adjustment in
copying
After completion of warmup, shading is performed and the currently set
OC mode sub scanning direction magnification ratio adjustment in
copying is performed. For the adjustment procedure, refer to the
previous descriptions.
50
∼ 99
∗2: Display after clearing each counter 
000 (0.75 sec) 
→ Blank (0.35 sec) → 000 (0.75 sec) → Blank (1.0 sec) → Repetition
Key operation
Display
Light reception/Detection
level select: Magnification
ratio display key
Display at the 3rd digit
“A”:
Light reception level display
“b”:
Document detection level display
Sensor select: Auto
magnification ratio select key
Sensor A: A3 (11 
× 17) document
size LED
Sensor B: A4 (8 1/2 
× 14) document
size LED
Sensor C: A4R (8 1/2 
× 11)
document size LED
Sensor D: B4 (8 1/2 
× 5 1/2)
document size LED
Key operation
Fusing temperature select: Magnification ratio display key
Key operation
Display
Mode select:
Exposure mode select
key
Copy density level:
Copy quantity keys
<LED lighting at each mode selection>
Auto mode: AUTO LED
Manual mode: MANUAL LED
Photo mode: PHOTO LED
Toner save mode: MANUAL + PHOTO LED
AETS mode: AUTO + PHOTO LED
Key operation
Display
Adjustment mode
select: Magnification
ratio display key
Auto magnification ratio adjustment:
 AUTO 
LED
Manual main scanning
direction magnification
ratio adjustment
Set value: Copy
quantity keys
Manual magnification ratio adjustment:
 MANUAL 
LED
OC mode document center off adjustment:
 PHOTO 
LED
Key operation
OC mode sub scanning direction magnification ratio in copying:
                                              Copy  quantity  keys
DM-2000
7 – 9
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
48
5
SPF mode sub scanning
direction magnification
ratio adjustment in
copying
<SPF is required>
After completion of warmup, shading is performed and the currently set
SPF mode sub scanning direction magnification ratio adjustment in
copying is performed. For the adjustment procedure, refer to the
previous descriptions.
33
45
∼ 99
6
OC mode sub scanning
direction magnification
ratio adjustment in FAX
<FAX kit is required>
After completion of warmup, shading is performed and the currently set
OC mode sub scanning direction magnification ratio adjustment in FAX is
performed. For the adjustment procedure, refer to the previous
descriptions.
50
∼ 99
7
SPF mode sub scanning
direction magnification
ratio adjustment in FAX
<FAX kit is required>
<SPF is required>
After completion of warmup, shading is performed and the currently set
SPF mode sub scanning direction magnification ratio in FAX is
performed. For the adjustment procedure, refer to the previous
descriptions.
50
∼ 99
50
1
Copy image position
adjustment
After completion of warmup, shading is performed and the currently set
value is displayed. For the adjustment procedure, refer to the previous
descriptions.
55
77
18
48
40
18
18
20
55
∼ 99
10
Paper off center
adjustment
After completion of warmup, shading is performed and the currently set
off center adjustment of each paper feed port is displayed. For the
adjustment procedure, refer to the previous descriptions.
50
∼ 99
Key operation
Display
Adjustment mode select:
  Exposure mode select key
Auto: SPF mode sub scanning
direction magnification ratio in copying
Set value:
  Copy quantity keys
Manual: RSPF mode sub scanning
direction magnification ratio in copying
Key operation
OC mode sub scanning direction magnification ratio in FAX:
                                              Copy  quantity  keys
Key operation
SPF mode sub scanning direction magnification ratio in FAX:
                                              Copy  quantity  keys
Key operation
Display
Adjustment mode
select:
Auto: Copy lead edge adjustment
Manual: SPF lead edge adjustment
Photo: Main cassette lead edge void
adjustment
Auto + Manual: Left edge void adjustment
Auto + Photo: Rear edge void adjustment
Auto + Manual + Photo: Option cassette
lead edge void adjustment
Manual + Photo: Multi bypass tray lead
edge void adjustment
None: Duplex lead edge void adjustment
Exposure 1: Print start position adjustment
Exposure mode select
key
Set value:
Copy quantity keys
Key operation
Display
Paper feed port tray
select: Tray select key
Main cassette: 
  Main cassette select LED
Off center adjustment
value: numeric keys
Manual paper feed: 
  Manual feed select LED
No. 2 cassette: 
  No. 2 cassette select LED
No. 3 cassette: 
  No. 3 cassette select LED
No. 4 cassette: 
  No. 4 cassette select LED
DM-2000
7  – 10
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
50
13
OC mode document off
center adjustment
After completion of warmup, shading is performed and the currently set
off center adjustment value for the document in OC reading is displayed.
For the adjustment procedure, refer to the previous descriptions.
50
∼ 99
16
SPF mode document off
center adjustment
<SPF is required>
After completion of warmup, shading is performed and the currently set
off center adjustment value for the document in SPF reading is
displayed. For the adjustment procedure, refer to the previous
descriptions.
61
∼ 99
18
Duplex memory reverse
position adjustment
<Not used>
After completion of warmup, shading is performed and currently set
value is displayed
58
∼ 99
19
Duplex rear edge void
adjustment
<Only when an option
is installed>
After completion of warmup, shading is performed and currently set
value is displayed.
37
52
70
∼ 99
51
2
Resist amount adjustment
After completion of warmup, shading is performed and the currently set
resist amount adjustment value is displayed.
50
(1 for
the
second 
cassette
only)
∼ 99
63
1
Shading data check
The copy lamp is shifted to the shading position and it is lighted with the
reference voltage at AD conversion fixed (Vref– = 0.5V, Vref+ = 4.5V).
The level of one pixel at the center at that time is displayed.
64
1
Self print mode
Disregards the optical system and performs self printing in 1 by 2 mode.
67
14
Printer Flash ROM
Data Download
The machine enters the version up mode of the printer PWB flash ROM.
For details, refer to the printer PWB flash ROM version up procedure
described later.
Key operation
Off center adjustment value: Copy quantity keys
Key operation
Off center adjustment value: Copy quantity keys
Key operation
Memory reverse position adjustment value:
  Copy 
quantity 
keys
Key operation
Display
Adjustment mode select:
  Exposure mode select key
Auto: SPF/R-SPF rear edge void
Set value:
  Copy quantity keys
Manual: R-SPF off center
Photo: R-SPF lead edge void
Key operation
Display
Resist amount adjustment:
Copy quantity keys
Adjustment mode select:
Exposure mode select key
Auto: Main cassette
Manual: Second cassette
Photo: Manual feed tray
Auto + Manual: Duplex
Display
Display section: Shading data
DM-2000
7  – 11
[8] FLASH ROM VERSION UP
PROCEDURE
1. MCU/E-SORT
A. Tool
● Machine
● PC
Operates on Windows 95/98.
● Level converter (UKOG-0002QSZZ) (with serial cable)
● Level converter (UKOG-0003QSZZ) (without serial cable)
● (Serial cable)
B. Procedures
1) Connect the PC and the level converter, and start Windows.
2) Turn off the power of the machine.
3) Remove the cap at the rear of the machine.
4) Connect the serial connector.
5) Turn on the power of the machine.
● The machine enters the download mode. (All LED lamps are
turned off. The machine accepts no key operations.)
6) Execute “mainte-Vxxx.exe” on the PC.
∗ Use “mainte_vxxx.exe” ver.1.04 or later.
7) Communication port/communication speed setting
● Select “Comport” in the option menu, and select the most
suitable item with consideration of PC environment, work time,
etc.
8) Select “Download the Program Data” in the SPECIAL folder, and
transfer data.
DM-2000
8  –  1
Page of 14
Display