GENERAL
 INFORMA
TION
Setting the user programs
1
Press and hold the light (
) key for more than 5 seconds
until all the alarm indicators (
, and 
)
blink and “– –” appears in the copy quantity display.
2
Enter a program number using the numeric keys.
The selected program number will blink in the copy quantity display.
If a mistake is made in steps 2 to 4, press the CLEAR (
) key. The
copier will return to step 2.
The program numbers are shown in the table below.
For example, to change the setting of the auto power shut-off timer,
press key 3.
Program name
Program No.
Auto clear time
1
Preheat mode
2
Auto power shut-off timer
3
Stream feeding mode
4
Auto power shut-off setting
5
Border line for 2 in 1 or 4 in 1
6
Rotation copy
7
Auto paper select mode
8
Auto tray switching
9
Auditing mode
10
Account number entry
11
Account number change
12
Account number deletion
13
Number of copies per account
14
Resetting account
15
Erase width adjustment
16
Layout in 2 in 1 copy
17
Layout in 4 in 1 copy
18
Offset of paper output tray
19
3
Press the START key.
For programs 1 to 9 and 16 to 19, the entered program number will be
steadily lit on the left side of the copy quantity display and the currently
selected parameter number for the program will blink on the right side.
For programs 10 to 15 (programs for auditing accounts), the display
varies with the program number. See page 40 for setting programs 10
to 15.
USER PROGRAMS
User programs
For operation of these programs after
step 3, see page 40.
39
GENERAL
 INFORMA
TION
USER PROGRAMS
4
Select the desired parameter using the numeric keys.
The entered parameter number will blink on the right side of the copy
quantity display.
The parameters are shown in the table below.
For example, to change the setting of the auto power shut-off timer to
60 min., press key 2.
5
Press the START key.
The right-hand number in the copy quantity display will be steadily lit
and the entered value will be stored.
6
To continue with other user programs, press the 
 key
and then repeat steps 2 to 5. To exit the user program
mode, press the light (
) key.
All the alarm indicators will go out.
User programs
Program name
Parameters
Auto clear time
0 e OFF
1 e 30 sec.
* 2 e 60 sec.
3 e 90 sec.
4 e 120 sec.
5 e 10 sec.
Preheat mode
0 e OFF
1 e 30 sec.
2 e 60 sec.
* 3 e 90 sec.
4 e 120 sec.
Auto power shut-off timer
* 1 e 30 min.
2 e 60 min.
3 e 90 min.
4 e 120 min.
5 e 240 min.
Stream feeding mode
* 0 e OFF
1 e ON
Auto power shut-off setting
0 e OFF
* 1 e ON
Border line for 2 in 1 or 4 in 1 * 0 e OFF
1 e ON
Rotation copy
0 e OFF
* 1 e ON
Auto paper select mode
0 e OFF
* 1 e ON
Auto tray switching
0 e OFF
* 1 e ON
Erase width adjustment
0 e 0 mm
1 e 5 mm
* 2 e 10 mm
3 e 15 mm
4 e 20 mm
Layout in 2 in 1 copy
* 1 e Pattern 1
2 e Pattern 2
Layout in 4 in 1 copy
* 1 e Pattern 1
2 e Pattern 2
3 e Pattern 3
4 e Pattern 4
Offset of paper output tray
0 e Upper OFF, lower OFF
* 1e Upper ON, lower ON
2 e Upper ON, lower OFF
3 e Upper OFF, lower ON
Factory default settings are indicated with an asterisk (*). For layout in 2 in 1 copy and 4 in 1 copy, see page 63.
If you select “0” (OFF) in a program, the corresponding
function will be disabled.
40
GENERAL
 INFORMA
TION
USER PROGRAMS
User programs
Settings for auditing accounts
Setting of user programs No. 10 to 15 varies with the program number. For
settings of all programs, first follow steps 1 to 3 in “Setting the user
programs” on page 38 to select a program. (1. Press the light (
) key for
more than 5 seconds. 2. Enter a program number (10 to 15) using the numeric
keys. 3. Press the START key.) Then follow the appropriate instructions for
the program.
Program No. 10: Auditing mode
If the auditing mode is enabled, copying is limited to operators with an
assigned 3-digit account number. A maximum of 20, 3-digit account numbers
can be assigned. Use program No. 11 to register account numbers.
When program No. 10 is entered, the current setting (0: OFF, 1:ON) will blink
on the right side of the copy quantity display.
1.
Select the desired setting using the numeric keys.
0:
OFF
1:
ON
2.
Press the START key.
The setting will be stored.
3.
To continue with other user programs, press the 
 key
and enter another program number. To exit the user
program mode, press the light (
) key.
1.
Enter a 3-digit account number using the numeric keys.
Any 3-digit number except “000” can be registered as an account
number.
2.
Press the START key.
If a number that is already registered or “000” is entered, the number
will blink in the copy quantity display.
3.
Repeat steps 1 and 2 for other account numbers.
4.
To continue with other user programs, press the 
 key
and enter another program number. To exit the user
program mode, press the light (
) key.
Program No. 11: Account number entry
Program No. 11 is used to register accounts. When program No. 11 is entered,
–––
” will blink in the copy quantity display.
If the number of accounts has reached the upper limit (20), “11E” will
appear in the copy quantity display. Press the 
 key. The copier will
return to step 2 on page 38.
41
GENERAL
 INFORMA
TION
USER PROGRAMS
User programs
Program No. 12: Account number change
Program No. 12 is used to change account numbers. When program No. 12
is entered, an account number will appear in the copy quantity display.
If no account number has been registered, “12E” will appear in the copy
quantity display. Press the 
 key. The copier will return to step 2 on page
38.
1.
To delete an individual account, press the 0 key.
To delete all accounts, press key 1.
2.
Press the START key.
If you have pressed the 0 key in step 1, an account number will appear
in the copy quantity display. Proceed to step 3.
If you have pressed key 1, all account numbers will be deleted. Proceed
to step 5.
3.
Use the copy ratio display (
) key to select the account
number to be deleted.
Use the 
 key to advance through the account numbers.
4.
Press the START key.
The specified account will be deleted.
5.
To continue with other user programs, enter another
program number. To exit the user program mode, press
the light (
) key.
Program No. 13: Account number deletion
Program No. 13 is used to delete accounts. When program No. 13 is entered,
“0” will blink on the right side of the copy quantity display.
If no account number has been registered, “13E” will appear in the copy
quantity display. Press the 
 key. The copier will return to step 2 on page
38.
1.
Use the copy ratio display (
) key to select the account
number to be changed.
Use the 
 key to advance through the account numbers.
2.
Press the START key.
The account number will be erased and “
–––
” will blink in the copy
quantity display.
3.
Enter a new account number using the numeric keys.
4.
Press the START key.
If a number that is already registered or “000” is entered, the number
will blink in the copy quantity display.
5.
Repeat steps 1 to 4 for other account numbers.
6.
To continue with other user programs, press the 
 key
and enter another program number. To exit the user
program mode, press the light (
) key.
Page of 18
Display

Sharp DM-2000 (serv.man12) User Manual / Operation Manual ▷ Download

  • DOWNLOAD Sharp DM-2000 (serv.man12) Service Manual ↓ Size: 216.41 KB | Pages: 18 in PDF or view online for FREE
  • Here you can View online or download the User Manual / Operation Manual for the Sharp DM-2000 (serv.man12) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp DM-2000 (serv.man12) Copying Equipment. Information contained in Sharp DM-2000 (serv.man12) User Manual / Operation Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.