AR-SP10/RP10 OPEREATIONAL DESCRIPTIONS
– 4 –
■ AR-SP10 (SPF)
3. Document size detection
1) Document size detection with the document set tray
When documents are set on the document set tray in the auto selection
mode of  paper/copy magnification ratio, the document size is detected
and paper and the copy magnification ratio are automatically selected. 
When different sizes of documents are set, the max. size is detected. 
The document width is detected by the document width sensors (W1,
W2, W3), and the document length is detected by the document length
sensors (L1, L2) to identify the document size. Judgement of the docu-
ment size is made in a certain timing after detecting the document with
the document set sensor (W0).
Note: Detection sensor ON: {, OFF: z
1) Document set (Document set sensor ON)
2) Document size detection (Document width sensors W1,
W2, W3 detect the document
width, and document length sen-
sors L1, L2 detect the document
length.)
3) Copier START key ON
4) SPF motor ON
5) Pickup solenoid ON
6) Pickup roller and paper feed roller rotation
7) Paper entry sensor detects the document presence.
8) PS roller rotation
9) Copying (Front surface of document)
10) Transport roller rotation
11) Paper exit roller rotation
12) Documents are fed to the paper exit tray.
13) Next document 
 (YES) 
 Go to 5).
 (NO)
14) SPF motor OFF
Document set 
size and set 
direction
Document width sensor
Document 
length sensor
W1
W2
W3
L1
L2
AB series
A5
{
z
z
z
z
B5
{
{
z
z
z
A5R
z
z
z
z
z
A4
{
{
{
z
z
B5R
z
z
z
{
z
A4R
{
z
z
{
z
8.5” x 13”
{
z
z
{
{
B4
{
{
z
{
{
A3
{
{
{
{
{
Inch 
series
8.5” x 5.5”
{
z
z
z
z
8.5” x 5.5”R
z
z
z
z
z
11” x 8.5”
{
{
{
z
z
11” x 8.5”R
{
z
z
{
z
8.5” x 13”
{
z
z
{
{
8.5” x 14”
{
z
z
{
{
11” x 17”
{
{
{
{
{
AR-SP10/RP10 ADJUSTMENTS
– 5 –
[5] ADJUSTMENTS
1. Auto white correction pixel adjustment
1) Open the SPF (RSPF) unit.
2) Execute Sim63-7.
3) The 7-seg display indicates the order number of the pixel of the
white sheet for SPF (RSPF) exposure correction in the SPF (RSPF)
position.
•  It will display on 7-seg display, if values are 93-229, and data are writ-
ten into the EEPROM.
(In this case, it means that the adjustment has been normally com-
pleted.)
•  It will display on 7-seg display, it values are 0-92 or 230-999, and data
are not written into the EEPROM.
•  It will display "--" on 7-seg display, it values is 1000 or larger, and data
are not written into the EEPROM.
(In these cases, the adjustment has not been normally completed.
Troubleshoot the cause and perform the adjustment again. )
Note: If the operation is executed with the SPF unit closed, an error
occurs. 
Also when the lens unit is replaced or when the optical axis of the
lens unit is shifted, an error occurs. 
In this case, it is necessary to perform the adjustment of the lens
unit described in “SPF white correction pixel position adjustment”
of the Service Manual of the machine. 
2. Magnification ratio adjustment
Note: • When performing this adjustment, check that the CCD unit is
properly installed.
• When performing this adjustment, check that the OC mode
adjustment in copying is completed.
1) Place a scale on the document table as shown below, and make a
normal copy to make a test chart.
2) Set the test chart to the SPF (RSPF) and make a normal copy.
3) Compare the copy and the test chart.
If an adjustment is needed, perform the following procedures.
4) Execute SIM 48-5.
5) The current correction value is displayed on the display section in
two digits.
6) Enter the set value, and press the START key.
The entered correction value is stored and a copy is made.
7) Change the TEXT mode.
The TEXT indicator lights up, and the current correction value of the
back surface sub scanning direction magnification ratio is displayed
on the display section in two digits.
8) Enter the set value, and press the START key.
The entered correction value is stored and a copy is made.
<Adjustment specifications>
Mode
Spec
SIM
Set value
Set 
range
Magnification 
ratio adjustment
Normal: 
±
 1.0%
SIM 48-5
AUTO: 
 
Surface
TEXT: Back
Add 1: 
0.1% increase
Reduce 1: 
0.1% decrease
1 ~ 99
Note: Since the printed paper is used as the test chart, 
place the scale in parallel to both sides.
AR-SP10/RP10 ADJUSTMENTS
– 6 –
3. Document off center adjustment
Note: When performing this adjustment, check that the paper off-center
is properly adjusted.
1) Set the center position adjustment test chart (made by yourself) on
the SPF (RSPF).
<Adjustment specifications>
Draw a line in the center of paper. (In the scanning direction)
2) Make a normal copy from the manual feed tray, and compare the
copy and the test chart.
If an adjustment is required, perform the following procedures.
3) Execute SIM 50-12.
4) The current off-center adjustment value is displayed on the display
section in two digits.
5) Enter the set value and press the START key.
The entered correction value is started and a copy is made.
<Adjustment specifications>
4. Image lead edge position adjustment
1) Set a scale on the OC table as shown below.
2) Make a copy, and use the copied paper as the document and make
a copy from SPF (RSPF) again.
3) Check the copied paper. If an adjustment is required, perform the
following procedures.
4) Execute SIM 50-6.
5) Set the SPF/RSPF lead edge position set value so that the image
similar to the adjusted image at the OC image lead edge position
described previously is printed.
<Adjustment specifications>
Mode
Specification
SIM
Set value
Set 
range
Document
off-center
(AR-RP10)
Simplex: 
Center 
±
 3.0mm
Duplex: 
Center 
±
 3.5mm
SIM 50-12
TEXT: 
SPF surface
PHOTO:
SPF back
Add 1: 
0.1mm shifted to
R side.
Reduce 1: 
0.1mm shifted to
L side.
1 ~ 99
Document
off-center
(AR-SP10)
AUTO: 
 
Surface
TEXT: 
 
SPF surface
Adjustment 
mode
SIM
Set value
Specification
Set
range
Image 
lead edge 
position
SIM 50-6
AUTO:
 
Front
TEXT:
 
Back
PHOTO:
 
Rear  edge
1step: 
 
0.1mm shift
Lead edge void: 
1 ~ 4mm
Image loss: 
3mm or less
1 ~ 99
Note: Since the printed paper is used as the test chart, 
place the scale in parallel to both sides.
AR-SP10/RP10 DISASSEMBLY AND ASSEMBLY
– 7 –
[6] DISASSEMBLY AND ASSEMBLY
The connector is of the lock type. When disconnecting the connector,
press the lock and pull it out. 
1. External fitting section
Note: Turn the paw in the arrow direction.
2. Paper feed unit section
1) Paper feed unit
2) Document feed section cover
3) Sensor PWB
1
2
2
3
2
1
1
1
2
1
1
1
3
2
2
4
Page of 22
Display

Click on the first or last page to see other AR-RP10 service manuals if exist.