Understanding calibration
To monitor print quality, print the following color reference pages:
• Color Charts from the Control Panel (see the
Configuration Guide
)
• Color Charts from Command WorkStation/Command WorkStation LE
(see the
Job Management Guide
)
• Color reference pages included with the user software (see the
User Software
Installation Guide
)
All these pages include fully saturated color patches and pale tints of cyan, magenta,
yellow, and black. Images with skin tones offer a very good basis for comparison. Save
and compare pages you printed at different times. If there is a noticeable change in
appearance, calibrate the Fiery X3e.
yellow, and black. Images with skin tones offer a very good basis for comparison. Save
and compare pages you printed at different times. If there is a noticeable change in
appearance, calibrate the Fiery X3e.
When you examine the Test Page, all color patches should be visible, even though they
may be very faint in the five percent and two percent range. Each color’s patch set
should show uniform gradation from patch to patch as the color lightens from 100
percent to zero percent.
may be very faint in the five percent and two percent range. Each color’s patch set
should show uniform gradation from patch to patch as the color lightens from 100
percent to zero percent.
If the solid density patches (100% cyan, magenta, yellow, or black) look less saturated
with time, show the pages to your copier/printer service technician to determine
whether adjusting the copier/printer can improve output.
with time, show the pages to your copier/printer service technician to determine
whether adjusting the copier/printer can improve output.
Checking calibration status
To verify whether the Fiery X3e is calibrated, which calibration set and output profile
were used, and when the copier/printer was last calibrated:
were used, and when the copier/printer was last calibrated:
• Print a Configuration page or Test Page from the Control Panel or Command
WorkStation/Command WorkStation LE.
• Select a calibration set in Calibrator (available from ColorWise Pro Tools)—the last
calibration and the user who performed it are displayed.
2
2-6
Color Calibration
Using Calibrator
ColorWise Pro Tools Calibrator allows you to calibrate the Fiery X3e using the
measurement method of your choice.
measurement method of your choice.
Changing the calibration has the potential to affect all jobs for all users, so consider
limiting the number of people authorized to perform calibration. Set an Administrator
password to control access to calibration (see the
limiting the number of people authorized to perform calibration. Set an Administrator
password to control access to calibration (see the
Configuration Guide
).
N
OTE
:
Multiple users can be connected to one Fiery X3e with ColorWise Pro Tools,
but only one user at a time can use Calibrator. An error message appears if you try to
calibrate when another user is using ColorWise Pro Tools to calibrate.
calibrate when another user is using ColorWise Pro Tools to calibrate.
Starting Calibrator
Start Calibrator from the ColorWise Pro Tools main window.
T
O
CALIBRATE
THE
F
IERY
X3
E
USING
C
ALIBRATOR
1.
Start ColorWise Pro Tools and connect to the Fiery X3e.
For instructions on configuring the connection to the Fiery X3e, see the
User Software
Installation Guide
.
N
OTE
:
If the connection to the Fiery X3e from Command WorkStation/Command
WorkStation LE (which also allows for access to ColorWise Pro Tools) is not
established, you can start ColorWise Pro Tools independently of Command
WorkStation/Command WorkStation LE.
established, you can start ColorWise Pro Tools independently of Command
WorkStation/Command WorkStation LE.
2
2-7
Using Calibrator
2.
Click Calibrator.
3.
Use the Calibrator window to perform the calibration method of your choice.
Procedures for each calibration method are described in subsequent sections of
this chapter.
this chapter.
2
2-8
Color Calibration
Expert Mode
Calibrator provides two modes: Standard Mode and Expert Mode. You can perform all
essential calibration tasks while in Standard Mode. Expert Mode offers two additional
options: Print Pages and View Measurements.
essential calibration tasks while in Standard Mode. Expert Mode offers two additional
options: Print Pages and View Measurements.
With the Print Pages option, print a calibration Comparison Page showing the results
of the new measurements with any profile associated with the currently selected
calibration set. You can also create a custom comparison page and save it as a
PostScript or Encapsulated PostScript (EPS) file called CALIB.PS. Next, print the file
to the Hold queue of the Fiery X3e from your application, or download it to the Hold
queue with Fiery Downloader. An additional way to create the CALIB.PS file is to
rename any job in the Hold queue using Command WorkStation/Command
WorkStation LE (see the
of the new measurements with any profile associated with the currently selected
calibration set. You can also create a custom comparison page and save it as a
PostScript or Encapsulated PostScript (EPS) file called CALIB.PS. Next, print the file
to the Hold queue of the Fiery X3e from your application, or download it to the Hold
queue with Fiery Downloader. An additional way to create the CALIB.PS file is to
rename any job in the Hold queue using Command WorkStation/Command
WorkStation LE (see the
Job Management Guide
).