6.  Click on Profile and then enter the name for the batch file that will act as you login script.
If the login script has been saved in any folder other than the default netlogon share of
WinRoot\system32\repl\import\scripts the path to this alternative folder should be included in the
User Profile Path. Also ensure that the user has sufficient rights to run the login script from this
alternative directory.
7.  Click on OK and then login as the selected user. The exported registry setting should be merged
with the client registry and the printer should then be fully configured.
Sharp Electronics (UK) Ltd., NIS Systems Support
NIS Bulletin 046.doc
Page:  5 of 7
Setting up a login script in Windows 2000
Setting up a login script within Windows 2000 is very similar to Windows NT4, the only exception
being that Windows 2000 has a different netlogon directory. Here we will write the login script and
utilise a batch file (.bat extension) that is a standard ASCII text file. The batch file historically is the
standard file type for a login script. Windows 2000 now also supports alternative script file types such
as Visual Basic or JScripts.
8.  Open the Notepad program by clicking on Start, Programs, Accessories and then Notepad. If the
customer already has login scripts enabled this extra entry to configure the driver can be included
in their existing login script.
The entry above will communicate with the server called w2kserver, look in the netlogon share
(WinRoot\SYSVOL\sysvol\DOMAIN NAME\scripts)  and then merge the already exported
configured registry branch named configured507.reg (Refer to NIS Bulletin 043 Extracting Printer
Configuration by using the Windows Registry & Export Facility 
for instructions on how to obtain
this file).
9.  A more advanced login script may look like the example below. You can see what each part of the
batch file will do by reading the REM commands.
10.  Once the login script has been written, save it in the WinRoot\SYSVOL\sysvol\DOMAIN
NAME\scripts folder on the Windows 2000 server as shown below. This folder is the default
shared folder called the NETLOGON folder. Also make sure that the registry key that you
previously saved is copied in to this folder.
Sharp Electronics (UK) Ltd., NIS Systems Support
NIS Bulletin 046.doc
Page:  6 of 7
11.  Now that the login script is in place we can configure the users properties so that when they next
login, the login script will run. On the Windows 2000 server, click Start, Programs, Administrative
Tools and Active directory Users and Computers
. Expand the domain and user folders and select
the user you wish to receive the login script.
12.  Click on Profile and then enter the name for the batch file that will act as your login script.
Login script and
exported
registry file.
Sharp Electronics (UK) Ltd., NIS Systems Support
NIS Bulletin 046.doc
Page:  7 of 7
               
     
13.  Click on OK, close Active directory Users and Computers and then login as the selected user.
The exported registry setting should be merged with the client registry and the printer should then
be fully configured.
Limitations of a login script
(a)  This method of supplying a registry key should only be used if a user logs on using their
credentials to the same computer or a workstation that has the same printer driver installed with
the same printer driver name. If a user logs on to a workstation where no printer driver is present
or the printer is named differently and the configuration data is imported, the registry of the
receiving workstation will have entries but no actual printer available. This could cause registry
problems.
(b)  Utilising a login script means that the exported configured registry branch will be merged with the
client computer at every logon and not as a one off.
(c)  Please also keep in mind that in a larger network it may not always be the same machine that
validates your logon. In the case of Windows NT4, a backup domain controller may validate your
logon. In order that all primary and backup domain controllers have the same information these
machines should be configured to replicate.
For more information on Windows Replication please refer to your Windows NT4 or 2000
documentation.
Page of 7
Display

Sharp AR-PB2A (serv.man27) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp AR-PB2A (serv.man27) Service Manual ↓ Size: 771.57 KB | Pages: 7 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp AR-PB2A (serv.man27) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-PB2A (serv.man27) Copying Equipment. Information contained in Sharp AR-PB2A (serv.man27) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.