Sharp AR-NS1 (serv.man16) Service Manual / Technical Bulletin ▷ View online
Sharp Electronics (UK) Ltd., NIS Systems Support
NIS Bulletin052.doc
Page: 1 of 1
Demonstration Mode for the AR-NS1 Scanner
Model Name:
ARNS1
Overview:
This bulletin explains how to enable the “Demo Scanner Mode” on the
AR287/337/407 & 507 Cougar series models.
AR287/337/407 & 507 Cougar series models.
This is intended to enable temporary scanner function without entering a
Product Key so that the copier can be demonstrated with full functionality.
(500 Scans Maximum).
Prerequisite:
1. AR-PB2a print controller with minimum 48MB RAM
.
2. AR-NC3D network card with the latest firmware version.
Procedure:
The demo version is an ICU Firmware update and is compatible with the
following versions:-
ICU
Demo
Version
PCU
OPE
AR-507
H2.31
H2.30
or higher
H2.30
or higher
AR407
M2.32
M2.30
or higher
M2.31
or higher
AR287/337
L2.32
L2.31
or higher
L2.31
or higher
1.
Update the ICU firmware version as shown above. (PCU & OPE may
also require upgrading).
also require upgrading).
2.
Enter Test Simulation 26-44 and set “B” to 20.
3.
Exit Test Simulation and reboot the copier.
Following the set-up of destinations etc, scanning can be performed as
normal for AR-NS1. When the scan counter has reached 500, the copier will
display “Not Ready” and the “Start” button will be disabled for scanning only.
Copying and Printing will still function.
Note: It is recommended to return the ICU firmware back to standard
production version following the completion of 500 scans.
Please refer to the “Firmware Revision Table” on the Sharp
Technical Website for the latest firmware information.
Technical Website for the latest firmware information.
Date:
15
th
January 2001
Model:
AR-NS1
Ref:
004
Colour Code: White
Page:
Page:
1 of 1
DOCUMENT SYSTEMS
SUPPORT BULLETIN
Display