DOWNLOAD Sharp AR-M700 (serv.man28) Service Manual ↓ Size: 292.59 KB | Pages: 38 in PDF or view online for FREE

Model
AR-M700 (serv.man28)
Pages
38
Size
292.59 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Self diag message and troubleshooting
File
ar-m700-sm28.pdf
Date

Sharp AR-M700 (serv.man28) Service Manual ▷ View online

: Feb. 9 2004
1
AR-M550/M620/M700  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 29
Main 
code
Sub 
code
Title
Fusing section high temperature 
trouble
H3
00/
HL1
Phenomenon
Display
Lamp
Message
01/
HL2
Details
Fusing section high 
temperature trouble
The fusing temperature 
exceeds 241.5°C. (An 
input voltage of 0.35V or 
less is detected.)
When fusing temperature 
control is started and a 
temperature of 242°C is 
detected 3 times 
continuously in sampling 
of 300 (450) msec 
interval. (Except for 
Japan)
02/
HL3
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Thermistor trouble
Control PWB trouble
Improper connection of 
the fusing section 
connector
AC power trouble
Remedy
Use SIM 5-2 to check 
flashing of the heater 
lamp.
When the lamp flashes 
normally.
• Check the thermistor 
and the harness.
• Check the thermistor 
input circuit on the 
control PWB.
When the lamp keeps 
ON.
• Check the AC PWB 
and the lamp control 
circuit on the control 
PWB.
Use SIM 14 to cancel the 
trouble
Note 
1
Main 
code
Sub 
code
Title
Fusing section low temperature 
trouble
H4
00/
HL1
Phenomenon
Display
Lamp
Message
01/
HL2
Details
Fusing section low 
temperature trouble
The set temperature is 
not reached within the 
specified time (normally 4 
min) after turning on the 
power relay.
The heater lamp does not 
turn off in 4 min after 
starting warming up.
02/
HL3
After completion of 
warming up, when the 
temperature below (*) is 
detected 5 times 
continuously during 
sampling in the interval of 
300(450) msec (EX 
JAPAN):
* H4-02/HL3: 80°C (Fixed 
level)
This temperature is -50°C 
lower than the 
temperature control level 
of H4-00/HL1, H4-01/
HL2.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Thermistor trouble
Heater lamp trouble
Control PWB trouble
Thermostat trouble
AC power trouble
Interlock switch
Remedy
Use SIM 5-2 to check 
flashing of the heater 
lamp.
When the lamp flashes 
normally.
• Check the thermistor 
and the harness.
• Check the thermistor 
input circuit on the 
control PWB.
When the lamp does not 
turn on.
• Check for 
disconnection of the 
heater lamp or the 
thermostat.
• Check the interlock 
switch.
• Check the AC PWB 
and the lamp control 
circuit on the control 
PWB.
Use SIM 14 to cancel the 
trouble
Note 
1
AR-M550/M620/M700  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 30
Main 
code
Sub 
code
Title
5-time continuous POD not-
reached JAM detection
H5
01
Phenomenon
Display
Lamp
Message
Details
5-time continuous POD 
not-reached JAM 
detection
When POD1 not-reached 
jam is detected 5 times 
continuously.
POD1 jam counter is 
backed up and used in a 
print job after turning on 
the power.
The counter is cleared 
when POD1 jam does not 
occur in a job or when the 
trouble is canceled.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
The fusing jam is not 
canceled completely. 
(Jam paper remains.)
Remedy
Check for jam paper in 
the fusing section. 
(Winding, etc.)
Case 2
Trouble 
position/
Cause
POD1 sensor trouble, or 
harness connection 
trouble
Remedy
Check the PODC1 
sensor harness and 
installation of the fusing 
unit.
Case 3
Trouble 
position/
Cause
Fusing unit installation 
trouble
Remedy
Use SIM 14 to cancel the 
trouble
Main 
code
Sub 
code
Title
Scanner feed trouble
L1
00
Phenomenon
Display
Lamp
Message
Details
Scanner feed trouble
Scanner feed is not 
completed within the 
specified time.
When MHP Soft is not 
detected within 2 sec 
after shifting the mirror 
base unit in the feeding 
direction.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Scanner unit trouble
The scanner wire is 
disconnected.
Remedy
Use SIM 1-1 to check 
scanning operation.
Note 
Main 
code
Sub 
code
Title
Scanner return trouble
L3
00
Phenomenon
Display
Lamp
Message
Details
Scanner return trouble
Scanner return is not 
completed within the 
specified time.
MHPSon is not detected 
within 10sec after starting 
the mirror base unit in the 
return direction.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Scanner unit trouble
The scanner wire is 
disconnected.
Remedy
Use SIM 1-1 to check 
scanning operation.
Note 
Main 
code
Sub 
code
Title
Main motor lock detection
L4
01
Phenomenon
Display
Lamp
Message
Details
Main motor lock detection
Three successive trouble 
signals are detected after 
600 msec from starting 
the main motor.
No trouble is detected 
after 600msec above.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Main motor trouble
Remedy
Use SIM 6-1 to check the 
main motor operation.
Note 
Case 2
Trouble 
position/
Cause
Improper disconnection 
of the harness between 
the PCU PWB and the 
main motor
Control circuit trouble
Remedy
Check the harness and 
the connector between 
the PCU PWB and the 
main motor.
Note 
AR-M550/M620/M700  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 31
Main 
code
Sub 
code
Title
Drum motor lock detection
L4
02
Phenomenon
Display
Lamp
Message
Details
Drum motor lock 
detection
The motor lock signal is 
detected for 1.5sec 
during rotation of the 
drum motor.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Drum motor trouble
Remedy
Use SIM 6-1 to check the 
drum motor operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the drum 
motor
Control circuit trouble
Remedy
Check the harness and 
the connector of the PCU 
PWB, and the drum 
motor.
Note 
Main 
code
Sub 
code
Title
Fusing motor lock detection
L4
03
Phenomenon
Display
Lamp
Message
Details
Fusing motor lock 
detection
Three successive trouble 
signals are detected after 
600 msec from starting 
the fusing motor.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Fusing motor trouble
Remedy
Use SIM 6-1 to check the 
fusing motor operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the fusing 
motor
Control circuit trouble
Remedy
Check connection of the 
harness and the 
connector between the 
PCU PWB and the fusing 
motor.
Note 
Main 
code
Sub 
code
Title
Developing motor lock detection
L4
04
Phenomenon
Display
Lamp
Message
Details
Developing motor lock 
detection
The motor lock signal is 
detected for 1.5sec 
during rotation of the 
developing motor
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Developing motor trouble
Remedy
Use SIM 6-1 to check the 
developing motor 
operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the 
developing motor
Control circuit trouble
Remedy
Check the harness and 
the connector between 
the PCU PWB and the 
developing motor.
Note 
Main 
code
Sub 
code
Title
Transfer belt separation motor 
trouble detection
L4
06
Phenomenon
Display
Lamp
Message
Details
Transfer belt separation 
motor trouble detection
The transfer belt home 
position sensor ON/OFF 
is not detected within the 
specified time (4 sec) 
during operation of the 
transfer belt (separation, 
contact).
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Transfer belt separation 
motor trouble
Remedy
Use SIM 6-1 to check the 
transfer belt motor 
operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
PCU PWB and the 
transfer belt separation 
motor.
Control circuit trouble
Remedy
Check connection of the 
harness and the 
connector between the 
PCU PWB and the fusing 
motor.
Note 
: Feb. 9 2004
1
AR-M550/M620/M700  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 32
Main 
code
Sub 
code
Title
Controller fan motor lock detection
L4
30
Phenomenon
Display
Lamp
Message
Details
Controller fan motor lock 
detection
The motor lock signal is 
detected during rotation of 
the controller fan motor.
The motor lock signal is 
detected during rotation of 
the HDD fan motor.
Section
Controller
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Fan motor trouble
Remedy
Use SIM 6-2 to check the 
fan motor operation.
Note 
Case 2
Trouble 
position/
Cause
Improper connection of 
the harness between the 
controller PWB and the 
fan motor.
Control circuit trouble
Remedy
Check the harness and 
the connector between 
the controller PWB and 
the fan motor.
Note 
Main 
code
Sub 
code
Title
Paper discharging fan trouble
L4
31
Phenomenon
Display
Lamp
Message
Details
Paper exit thermistor 
open or short.
When the temperature of 
100°C or above (entered 
value 235) is detected in 
the paper exit thermistor 
3 times or more 
continuously.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Defective contact of 
paper exit thermistor 
harness
Remedy
Check connection of the 
paper exit thermistor 
harness and the connector.
Note 
Case 2
Trouble 
position/
Cause
Fan motor trouble
Remedy
Use SIM 6-2 to check the 
fan motor operation.
Note 
Case 3
Trouble 
position/
Cause
PCU PWB, harness 
connection between fan 
and motor trouble
PCU circuit trouble
Thermistor (TH_EX) 
trouble
Remedy
Check the PCU PWB, the 
harness between fan and 
motor, and the connector.
Note 
1
1
Main 
code
Sub 
code
Title
Polygon motor lock detection
L6
10
Phenomenon
Display
Lamp
Message
Details
Polygon motor lock 
detection
It is judged that the 
polygon motor lock signal 
of the LSU is not 
outputted.
The polygon motor lock 
signal is checked in an 
interval of 10sec after 
starting the polygon 
motor, and it is found that 
the polygon motor is not 
rotating normally.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Polygon motor trouble
Remedy
Use SIM 61-1 to check 
the polygon motor 
operation.
Note 
Case 2
Trouble 
position/
Cause
Disconnection or 
breakage of the LSU 
connector or the harness 
in the LSU
Remedy
Check connection of the 
harness and the 
connector.
Replace the LSU.
Note 
Main 
code
Sub 
code
Title
No full wave signal
L8
01
Phenomenon
Display
Lamp
Message
Details
The full wave signal is not 
detected.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Disconnection or 
breakage of the PCU 
PWB connector or the 
harness in the power unit
Remedy
Check connection of the 
harness and the 
connector.
Note 
Case 2
Trouble 
position/
Cause
PCU PWB trouble
Remedy
Replace the PCU PWB.
Note 
Case 3
Trouble 
position/
Cause
12V power source trouble
Remedy
Replace the power unit.
Replace the controller 
connection mother board.
Note 
Page of 38