DOWNLOAD Sharp AR-M700 (serv.man16) Service Manual ↓ Size: 4.58 MB | Pages: 25 in PDF or view online for FREE

Model
AR-M700 (serv.man16)
Pages
25
Size
4.58 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Details of each section - 2 Paper feed, paper transport
File
ar-m700-sm16.pdf
Date

Sharp AR-M700 (serv.man16) Service Manual ▷ View online

AR-M550/M620/M700  DETAILS OF EACH SECTION  6 - 17
4) Remove the torque limiter.
a-5. Lift wire (Rear)
1) Remove the  paper feed tray units 1 and 2. (See “a. Paper feed
tray units 1 and 2” in “(Paper feed tray sections 1 and 2)”
2) Remove the E-ring, slide the winding pulley, and loosen the wire. 
3) Release the pawl, and remove the wire.
4) Remove the plastic E-ring.
5) Remove the wire.
Pass the nylon clamp.
Attach so that the red wire is on the outside.
Turn it clockwise to fit with the T-shape pin position and insert.
a-6. Lift wire (Front)
1) Remove the  paper feed tray 1/2 unit. (See “(Paper feed tray sec-
tions 1 and 2)” in “a. Paper feed tray units 1 and 2”)
2) Push down the tray and remove the screw, and remove the paper
feed tray 1/2 front cabinet. 
AR-M550/M620/M700  DETAILS OF EACH SECTION  6 - 18
3) Remove the E-ring, slide the winding pulley, and loosen the wire.
4) Release the pawl, and remove the wire.
5) Remove the plastic E-ring.
6) Remove the wire. 
Pass the nylon clamp.
Attach so that the red wire is on the outside.
Turn it counterclockwise and fit with the T-shape pin position and
insert.
b-1. Paper remaining quantity sensor PWB
1) Remove the paper feed tray units 1 and 2. (See “a. Paper feed tray
units 1 and 2” in this section)
2) Disconnect the connector, and remove the paper remaining quan-
tity sensor PWB.
b-2. Paper remaining quantity detector
1) Remove the paper feed tray units 1 and 2. (See “a. Paper feed tray
units 1 and 2” in this section)
2) Disconnect the connector, and remove the paper feed tray lock
arm unit. 
3) Disconnect the connector, and remove the paper remaining quan-
tity detector.
: Feb. 6 2004
1
AR-M550/M620/M700  DETAILS OF EACH SECTION  6 - 19
b-3. Paper feed trays 1 and 2 sensor
1) Remove the rear cabinet.
2) Disconnect the connector, and remove the paper feed trays 1 and
2 sensor.
b-4. Dry heater
1) Remove the rear cabinet. (See “b-3. Paper feed trays 1 and 2 sen-
sor” in this section)
2) Disconnect the connector from the dehumidifier heater relay PWB.
4) Remove the dry heater unit.
4) Remove the dry heater.
3) Remove the paper feed tray unit, and remove the dry heater band.
1
1
1
AR-M550/M620/M700  DETAILS OF EACH SECTION  6 - 20
(Paper feed trays 3 and 4)
A. Major parts and signal functions
M1SS PWB
M2SS PWB
14
13
12
11
10
1
9
8
7
6
5
4
3
2
24
23
22
21
20
19
18
17
16
15
25
26
27
28
29
30
32
31
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
12
11
10
12
11
10
13
14
15
16
17
18
13
14
15
16
17
18
5
4
3
2
1
6
5
4
3
2
1
6
33
34
3
2
1
3
2
1
PCU PWB
GND2
M1SS1
M1SS2
M1SS3
M1SS4
GND2
M1SPD
GND2
M2SS1
M2SS2
M2SS3
M2SS4
GND2
M2SPD
(NC)
(NC)
SMP-18V-NC/SMR-18V-N
+5V2
+5V2
S6B-PH-K-S
S6B-PH-K-S
PHR-3
PHR-3
M2SPD
GND2
M1SS1
M1SS2
M1SS3
M1SS4
M2SS1
M2SS2
M2SS3
M2SS4
M1SPD
(NC)
GND2
GND2
(NC)
GND2
+5V2
+5V2
CN-15
GND2
GND2
/GBPWM
/MHVREM
MHV-T
/THV+PWM
/CHV-PWM
/CHV-REM
/CHVACPWM
/CHVACREM
/DVPWM
/DVREM
HVREM
(NC)
DSW-F
+24V1
(NC)
THV+REM
M2SS1
M2SPD
GND2
M2SS4
M2SS3
M2SS2
M1SPD
GND2
M1SS4
M1SS3
M1SS2
M1SS1
+5V2
+5V2
GND2
GND2
B34B-PHDSS-B
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
11
10
11
10
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
11
10
11
10
3
1
1
2
2
3
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
1
9
8
7
6
5
4
3
2
25
26
27
28
29
30
31
32
3
2
1
3
2
1
3
2
1
2
1
3
2
1
3
2
1
3
2
1
2
1
1
2
2
1
2
1
2
1
2
1
1
3
2
1
2
1
2
GND2
GND2
GND2
+24V1
PHR-3
PHR-3
GND2
GND2
GND2
+24V1
SMR-11V-N/SMP-11V-NC
/M1PUS
M1PED
M1LUD
M1PFD
/M1PUS
M1PED
M1LUD
M1PFD
GND2
GND2
GND2
+24V1
PHR-3
PHR-3
GND2
GND2
GND2
+24V1
SMR-11V-N/SMP-11V-NC
/M2PUS
M2PED
M2LUD
M2PFD
/M2PUS
M2PED
M2LUD
M2PFD
+5V2
+5V2
+5V2
+5V2
+5V2
+5V2
+5V2
+5V2
CN-16
PHR-2
GND2
PHNR-02-H+BU02P-TR-P-H
+24V1
/M1PFC
PHNR-02-H+BU02P-TR-P-H
+24V1
/DSKPFC1
SMR-03V-N/SMP-03V-NC
M1PWS
GND2
M1PWS
GND2
+24V1
+24V1
/M1PUS
/M2PUS
GND2
GND2
M1PED
M2PED
+5V2
+5V2
GND2
GND2
M1LUD
M2LUD
+5V2
+5V2
+5V-M1PFD
+5V-M2PFD
GND2
GND2
M1PFD
M2PFD
+24V1
+24V1
/M1PFC
/DSKPFC1
M1LUM
Vref
GND2
GND2
(NC)
M1PWS
B32B-PHDSS-B
+5V-M1PFD
+5V-M1PFD
+5V-M2PFD
+5V-M2PFD
M1LUM
Vref
Vref
SMP-02V-NC/SMR-02V-N
SMP-02V-NC/SMR-02V-N
PHR-3(RED)
PHR-3(RED)
Soldering
M1PED
M1LUD
M1PFD
M1PUS
M1LUM
M1PWS
MM
M1SPD
DSKPFC1
M1PFC
14
13
12
11
10
1
9
8
7
6
5
4
3
2
24
23
22
21
20
19
18
17
16
15
25
26
27
28
29
30
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
10
10
1
2
2
1
2
1
CN-17
M2LUM
GND2
+24V1
/T1PFC
+24V1
/M2PFC
+24V1
/DSKPFC2
GND2
TXD-FIN
RXD-FIN
RES-FIN
/DTR-FIN
/DSR-FIN
GND2
+5V2
/MM
MMCLK
MM-T
GND2
TANSET
+5V2
GND2
GND2
DSW-DSK
+5V2
(NC)
TSW-LED
TSW
(NC)
B30B-PHDSS-B
GND2
TXD-FIN
RXD-FIN
/DTR-FIN
/DSR-FIN
RES-FIN
GND2
+24V1
/M2PFC
M2LUM
SMR-10V-N/SMP-10V-NC
PHR-2
GND2
PHNR-02-H+BU02P-TR-P-H
+24V1
/M2PFC
M2LUM
M2LUM
M2PFC
5
4
3
2
1
S5B-PH-K-S
GND2
+5V2
/MM
MMCLK
MM-T
M2PED
M2LUD
M2PFD
M2PUS
M2SPD
7
8
9
7
8
9
11
12
12
1
1
1
2
2
10
5
4
4
3
3
6
6
10
5
11
7
8
9
9
8
7
10
11
11
Page of 25
Display

Click on the first or last page to see other AR-M700 (serv.man16) service manuals if exist.