DOWNLOAD Sharp AR-M550 (serv.man23) Service Manual ↓ Size: 7.48 MB | Pages: 56 in PDF or view online for FREE

Model
AR-M550 (serv.man23)
Pages
56
Size
7.48 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARM550 620 Installation Manual
File
ar-m550-sm23.pdf
Date

Sharp AR-M550 (serv.man23) Service Manual ▷ View online

: Jan. 9 2004
1
AR-M550/M620  INSTALLATION MANUAL  (AR-FR11)  7 - 2
(4) Reattach the control PWB.
1) Reattach the control PWB unit to the main unit.
2) Reconnect the two flat cable connectors that have been removed
in step (2).
3) Secure the unit with the four screws.
4) Return the grips to their original positions.
5) Pull out the grip of the main unit, pass it through the hole shown in
the illustration, then reattach the upper right cabinet that has been
removed in step (2) to the main unit, and secure it with the two
screws.
Reconnect all the cables that have been removed in step (2)-1) to
the control PWB.
If another peripheral device must be installed, carry out the following
steps at the end of the installation work.
(5) Turn on the main switches of the main unit.
1) Insert the power plug of the main unit to the outlet.
2) Turn on the main power switch and then close the front cabinet.
3) Turn the main switch located on the right side of the main unit to
the "ON" position.
(6) Make preparations for enabling the data security 
function.
To enable the data security function, use the keys on the operation
panel to enter the product key.
For entry of the product key, see the section of key operator programs
of the operation manual for the main unit.
After completing product key entry, turn off the power switch and the
main power switch of the main unit and then turn on the power switch
and the main power switch again.
(7) Make user settings of the data security function.
You can make operation settings of the data security function using a
key operator program.
If some files have been stored using the quick file function before
installation of AR-FR11, be sure to execute [CLEAR ALL MEMORY]
after installation to delete all the stored files.
Grip
Screws
Upper right cabinet
: Jan. 9 2004
1
AR-M550/M620  INSTALLATION MANUAL  (AR-PK5)  8 - 1
[8] AR-PK5 INSTALLATION
<Before installation>
• To enable the PS expansion function, the product key must be
acquired.
• For models on which the printer and network functions cannot be
used, a printer expansion ROM and a Print Server Card must be
installed in advance.
Parts included
• CD-ROM: 1 pc.
• Product key sheet: 1 sheet
(1) Enable the PS expansion function.
To enable the PS expansion function, use the keys on the operation
panel to enter the product key.
For entry of the product key, see the online manual included in the sup-
plied CD-ROM or the section of key operator programs of the operation
manual for the main unit.
After completing product key entry, turn off the power switch and the
main power switch of the main unit and then turn on the power switch
and the main power switch of the main unit again.
(2) Check the operation of the PS expansion function.
1) Use the keys on the operation panel to execute test page printing
and print the PS FONT LIST as a test print. 
2) Installation of the driver software to the computer server and its
setting must be performed by the customer or based on discussion
with the customer.
For installation of the driver software, see the installation guide.
3) Finally, execute printing from the computer server and check that
printing is performed normally.
: Jan. 9 2004
1
AR-M550/M620  INSTALLATION MANUAL  (AR-NS3)  9 - 1
[9] AR-NS3 INSTALLATION
<Before installation>
• To enable the scanner function, the product key must be acquired.
• For models on which the printer and network functions cannot be
used, a printer expansion ROM and a Print Server Card must be
installed in advance.
Parts included
• CD-ROM: 1 pc.
• Product key sheet: 1 sheet
• Installation guide: 1 sheet
(1) Enable the scanner function.
To enable the scanner function, use the keys on the operation panel to
enter the product key.
For entry of the product key, see the section of key operator programs
of the operation manual for the main unit.
After completing product key entry, turn off the power switch and the
main power switch of the main unit and then turn on the power switch
and the main power switch of the main unit again.
(2) Check the operation of the scanner function.
1) Installation of the driver software to the computer server and its
setting must be performed by the customer or based on discussion
with the customer.
2) Finally, referring to the installation guide, set the destination profile.
Send image data and check that the image is properly received.
AR-M550/M620  INSTALLATION MANUAL  (AR-FX8)  10 - 1
[10] AR-FX8/AR-MM9 INSTALLATION
<Before installation>
• For installation of AR-FX8, the MFP control PWB unit must have
been installed.
• Start installation after checking that the LINE indicator and the DATA
indicator below it on the operation panel are neither lit nor blinking.
1) Turn off the power switch of the main unit.
<1>Turn the power switch located on the right side of the main unit to
the "OFF" position.
<2>Open the front cabinet and turn the main power switch to the
"OFF" position.
<3>Remove the power plug of the main unit from the outlet.
2) Remove the MFP control PWB.
<1>Remove the two screws that secure the upper right cabinet and
remove the upper right cabinet.
<2>Remove the four screws that secure the MFP control PWB unit to
the main unit.
<3>Raise the two grips and hold them to pull out the MFP control PWB
unit until the stopper is engaged.
<4>Remove the two flat cable connectors.
<5>While using your finger to release the stopper, pull the MFP control
PWB unit out of the main unit.
<Step for mounting extended memory (AR-MM9)>
*
If you need not mount an extended memory, proceed to step 4).
3) Mount an extended memory.
Mount an extended memory to the socket located on the back of
the FAX interface PWB unit.
4) Attach the FAX interface PWB unit.
Connect the FAX interface PWB unit to the FAX interface PWB
connector (100 pin) on the MFP control PWB unit and secure it
with two screws J.
5) Connect the FAX interface cable.
Connect the FAX interface cable to the MFP control PWB unit.
<Caution>
Ensure that both ends of the connector are securely locked and the
connector is not inserted at an angle.
Parts included
FAX interface PWB unit
(1 pc.)
 FAX interface cable
(1 pc.)
Line cable
(1 pc.)
Screw J (small)
(2 pcs.)
1
2
Screws
Upper right
 cabinet
2
2
3
3
4
5
5
2
1
Extended memory
FAX interface PWB unit
FAX interface PWB unit
Screws J
Page of 56
Display

Click on the first or last page to see other AR-M550 (serv.man23) service manuals if exist.