AR-M550/M620 SIGNAL NAME LIST 14 - 10
THPS1
Transfer belt contact/
separation home position
sensor 1
separation home position
sensor 1
Transfer belt separation home
position detection 1
position detection 1
—
Contact
7
6
PCU
Not used.
THPS2
Transfer belt contact/
separation home position
sensor 2
separation home position
sensor 2
Transfer belt separation home
position detection 2
position detection 2
—
Contact
7
14
PCU
TH-RA
Machine temperature detection
signal
signal
Machine temperature detection
—
—
21
10
PCU
THV+PWM
Transfer charger output control
signal (THV)
signal (THV)
Transfer charger output control
(PWM control)
(PWM control)
—
—
15
8
PCU
THV+REM
Transfer charger control signal
(THV)
(THV)
Transfer charger ON/OFF
control
control
ON
OFF
15
9
PCU
TLS
Waste toner pipe lock detection
signal
signal
Waste toner pipe lock detection
—
Lock (Tilt)
8
16
PCU
TM1A
Toner motor 1 control signal
Toner motor 1 ON/OFF control
—
—
11
1
PCU
TM1B
Toner motor 1 control signal
Toner motor 1 ON/OFF control
—
—
11
3
PCU
TM2A
Toner motor 2 control signal
Toner motor 2 ON/OFF control
—
—
11
5
PCU
TM2B
Toner motor 2 control signal
Toner motor 2 ON/OFF control
—
—
11
7
PCU
TNCA
Waste toner full detection
signal
signal
Waste toner full detection
—
—
11
12
PCU
Not used.
TRC_LCC
LCC paper feed timing signal
LCC paper feed timing control
(Output from PCU)
(Output from PCU)
—
—
18
13
PCU
TRMA
Transfer roller 15 drive motor
control signal (Phase A)
control signal (Phase A)
Transport roller 15 drive motor
control
control
—
—
10
17
PCU
TRMB
Transfer roller 15 drive motor
control signal (Phase B)
control signal (Phase B)
Transport roller 15 drive motor
control
control
—
—
10
19
PCU
TRMXA
Transfer roller 15 drive motor
control signal (Phase /A)
control signal (Phase /A)
Transport roller 15 drive motor
control
control
—
—
10
18
PCU
TRMXB
Transfer roller 15 drive motor
control signal (Phase /B)
control signal (Phase /B)
Transport roller 15 drive motor
control
control
—
—
10
20
PCU
TSGOUT
Toner den misty sensor gain
control signal
control signal
Toner density sensor gain
control
control
—
—
12
20
PCU
TURM
Transfer separation motor
control signal
control signal
Transfer unit separation control
Stop
Contact/
Release
Release
7
16
PCU
TXD_CCD1
Serial I/F data (CCD)
Serial I/F data (Scanner control
PWB - CCD)
PWB - CCD)
—
—
1
63
SCN
TXD_CCD2
Serial I/F data (CCD)
Serial I/F data (Scanner control
PWB - CCD)
PWB - CCD)
—
—
10
14
SCN
TXD_FIN
Serial I/F data (Finisher)
Serial I/F data (PCU PWB -
Finisher)
Finisher)
—
—
17
11
PCU
TXD_LCC
Serial I/F data (LCC)
aerial I/F data (Controller -
Scanner control PWB)
Scanner control PWB)
—
—
18
3
PCU
TXD_SCN
Serial I/F data (Scanner control
PWB)
PWB)
Serial I/F data (Controller -
Scanner control PWB)
Scanner control PWB)
—
—
9
8
SCN
VCCW_SCN Scanner flash ROM write
protect signal
Scanner flash ROM write
protect
protect
Write
enable
9
10
SCN
VFM-BKL
Exhaust fan motor control
signal (Rear left)
signal (Rear left)
Exhaust fan motor control
signal (O
signal (O
3
exhaust, process
section heat exhaust)
Max. force
of wind
Stop
5
22
PCU
VFM-BKR
Exhaust fan motor control
signal (Rear right)
signal (Rear right)
Exhaust fan motor control
signal (Exhaust, duplex (ADU)
section cooling)
signal (Exhaust, duplex (ADU)
section cooling)
Max. force
of wind
Stop
6
17
PCU
VFM-EX1
Exhaust fan motor control
signal (LSU top plate front
side)
signal (LSU top plate front
side)
Exhaust fan motor control
signal (O
signal (O
3
exhaust, process
section heat exhaust)
Max. force
of wind
Stop
5
4
PCU
VFM-EX2
Exhaust fan motor control
signal (LSU top plate center)
signal (LSU top plate center)
Exhaust fan motor control
signal (O
signal (O
3
exhaust, process
section heat exhaust)
Max. force
of wind
Stop
5
10
PCU
VFM-EX3
Exhaust fan motor control
signal (LSU top plate rear side)
signal (LSU top plate rear side)
Exhaust fan motor control
signal (O
signal (O
3
exhaust, process
section heat exhaust)
Max. force
of wind
Stop
5
16
PCU
VIDEO
Image signal
Image signal to LSU
—
—
20
21
PCU
VIDEOin-
Image signal
Image signal from controller to
PCU PWB
PCU PWB
—
—
9
21
PCU
Signal name
Name
Function/Operation
Connector level
Connector
No.
Pin No.
PWB
name
Remark
"L"
"H"
AR-M550/M620 SIGNAL NAME LIST 14 - 11
∗∗∗∗
1: Multi-stage tray vertical size detection
∗∗∗∗
2: Options
VIDEOin+
Image signal
Image signal from controller to
PCU PWB
PCU PWB
—
—
9
23
PCU
VPMA
Paper transport motor control
signal (Phase A)
signal (Phase A)
Paper vertical transport motor
control (Phase A)
control (Phase A)
—
—
10
21
PCU
VPMB
Paper transport motor control
signal (Phase B)
signal (Phase B)
Paper vertical transport motor
control (Phase B)
control (Phase B)
—
—
10
23
PCU
VPMXA
Paper transport motor control
signal (Phase /A)
signal (Phase /A)
Paper vertical transport motor
control (Phase /A)
control (Phase /A)
—
—
10
22
PCU
VPMXB
Paper transport motor control
signal (Phase /B)
signal (Phase /B)
Paper vertical transport motor
control (Phase /B)
control (Phase /B)
—
—
10
24
PCU
VRB
Laser power control signal
Laser power control
—
—
22
17
PCU
WAKE UP
Reset trigger signal from
energy-saving mode
energy-saving mode
Reset trigger from energy
saving mode
saving mode
Energy-
save reset
9
11
SCN
WHPR2
Dehumidifier heater power
relay 2 control signal
relay 2 control signal
Dehumidifier heater control
Relay ON
Relay OFF
19
18
PCU
XH
Touch panel area identification
signal (Vertical direction)
signal (Vertical direction)
Touch panel area identification
(Vertical direction) X axis
(Vertical direction) X axis
—
—
1
96
SCN
XL
Touch panel coordinates signal
(Vertical direction)
(Vertical direction)
Touch panel coordinates
identification (Vertical direction)
X axis
identification (Vertical direction)
X axis
—
—
1
46
SCN
YH
Touch panel area identification
signal (Horizontal direction)
signal (Horizontal direction)
Touch panel area identification
(Horizontal direction) Y axis
(Horizontal direction) Y axis
—
—
1
45
SCN
YL
Touch panel coordinate signal
(Horizontal direction)
(Horizontal direction)
Touch panel coordinates
identification (Horizontal
direction) Y axis
identification (Horizontal
direction) Y axis
—
—
1
95
SCN
Vertical size detection: Connector level
Paper size
Multi-stage tray 1
M1SS1
M1SS2
M1SS3
M1SS4
AB series
Inch series
China series
Multi-stage tray 2
M2SS1
M2SS2
M2SS3
M2SS4
1
L
L
H
L
B5
Extra
K16
2
H
L
H
L
A4
A5R
LT
INVR
A4
A5R
3
H
L
L
L
B5R
EX-R
K16R
4
H
H
L
L
A4R
LTR
A4R
5
L
H
L
L
Foolscap
Extra
Foolscap
6
L
H
L
H
B4
LGL
K8
7
L
L
L
H
A3
WLT
0
H
H
H
H
Tray not installed
No.
CV_SIZE3
CV_SIZE2
CV_SIZE1
CV_SIZE0
Paper size
0
0
0
0
0
none
1
0
0
0
1
A3
2
0
0
1
0
A4
3
0
0
1
1
LT
4
0
1
0
0
B4
5
0
1
0
1
LG
6
0
1
1
0
WLT
7
0
1
1
1
INV
8
1
0
0
0
B5
9
1
0
0
1
Extra
10
1
0
1
0
A5
11
1
0
1
1
F4
12
1
1
0
0
A4R
13
1
1
0
1
B5R
14
1
1
1
0
LTR
15
1
1
1
1
A5R
Signal name
Name
Function/Operation
Connector level
Connector
No.
Pin No.
PWB
name
Remark
"L"
"H"
Memo
LEAD-FREE SOLDER
The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder.
The alphabet following the LF mark shows the kind of lead-free solder.
(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD
When repairing a lead-free solder PWB, use lead-free solder thread.
Never use conventional lead solder thread, which may cause a breakdown or an accident.
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use
soldering iron is recommendable.
(2) NOTE FOR SOLDERING WORK
Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering capacity is
inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed
inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed
the heat-resistive temperature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is
confirmed.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after
completion of soldering work.
If the soldering iron tip is discolored black during soldering work, clean and file the tip with steel wool or a fine filer.
Example:
5mm
Lead-Free
Solder composition
code (Refer to the
table at the right.)
code (Refer to the
table at the right.)
<Solder composition code of lead-free solder>
Solder composition
Sn-Ag-Cu
Sn-Ag-Bi
Sn-Ag-Bi-Cu
Sn-Ag-Bi-Cu
Sn-Zn-Bi
Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
Bi-Sn-Ag-P
Bi-Sn-Ag
Bi-Sn-Ag
a
b
z
i
n
s
p
Solder composition code
a