AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 2
Note: Adjusting the output voltage requires the ability to measure
internal impedance of 1000 MW.
This adjustment is needed in the following situations: 
• The high voltage power PWB (MC/DV/TC) has been replaced.
• U2 trouble has occurred. 
• The PCU PWB has been replaced.
• The EEPROM of the PCU PWB has been replaced.
 
(Main charger grid voltage adjustment)
      
  
  
  
1) Remove the rear cover of the machine.
2) Apply a digital multi-meter to the connector CN2 pin (7) of the high
voltage PWB and the chassis GND.
ADJ11
Adjusting the image quality in scan mode
ADJ 11A
Adjust the scan mode image density for all modes at once
46-21
ADJ 11B
Scan mode image density adjustment/individual setup 
(standard mode)
46-21, 46-22
ADJ 11C
Scan mode image density adjustment/individual setup 
(small-character mode)
ADJ 11D
Scan mode image density adjustment/individual setup 
(fine mode)
ADJ 11E
Scan mode image density adjustment/individual setup 
(super fine mode)
ADJ 11F
Adjust the image gamma in scanner mode
46-27
ADJ12
Common image quality adjustments for all of 
copy, scan, and fax modes
ADJ 12A
Correct the image density in original table mode/SPF 
mode
46-20
ADJ 12B
Set up the auto mode operation for copy, scan, and fax
46-19
ADJ 12C
Adjust the shading reference value (gain adjustment) 
46-17
ADJ13
Adjusting the fusing paper guide position
ADJ 14
Adjusting the paper size detection
ADJ 14A
Adjust the paper width sensor for the manual paper feed 
tray
40-2
ADJ 14B
Adjust the paper width sensor for paper feed tray 3
40-12
ADJ 14C
Adjust the paper width sensor for the SPF paper feed tray
53-6
ADJ 15
Adjusting the original size detection (in original 
table mode)
ADJ 15A
Adjust the detection point of the original size sensor (in 
original table mode)
ADJ 15B
Adjust the sensitivity of the original size sensor
ADJ16
Adjusting the touch panel coordinates
65-1
ADJ17
Adjusting the supply voltage
Job No
Adjustment item list
Simulation
ADJ 1
Adjusting high voltage values
ADJ 1A
Adjust the main charger grid voltage
Item/operation mode
Simulation
High voltage power PWB (MC/DV/TC)
Setting 
range
Default
Adjustment voltage 
(monitor voltage)
Connector
Pin #
Actual 
voltage
Copy
Auto mode
8-2
AUTO
200 – 1000
580
–620±5v
CN2
3
–590±5v
Text mode
CHARACTER
200 – 1000
580
–620±5v
CN2
3
–590±5v
Text/photo mode
MIX
200 – 1000
580
–620±5v
CN2
3
–590±5v
Photo mode
PHOTO
200 – 1000
580
–620±5v
CN2
3
–590±5v
Printer
All modes
PRINTER
200 – 1000
580
–620±5v
CN2
3
–590±5v
FAX
All modes
FAX
200 – 1000
580
–620±5v
CN2
3
–590±5v
CN2
3
AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 3
3) Go through the modes specified in Simulation 8-2.
4) Select the number that corresponds to the adjustment item using
the numeric keypad. 
5) Press the Start key. 
6) Press the start key to have the voltage output for 30 seconds.
The operation can be stopped with the CUSTOM SETTINGS key.
If the output voltage is not within the requirement, do the following
steps. 
7) Enter the adjustment value using the numeric keypad. 
8) Press the Start key
(The adjustment value is put into memory, and the corresponding
voltage is output for 30 seconds.) 
Repeat steps 7 to 8 until the output requirement is satisfied.
This adjustment is needed in the following situations: 
• The high voltage power PWB (MC/DV/TC) has been replaced.
• U2 trouble has occurred. 
• The PCU PWB has been replaced.
• The EEPROM of the PCU PWB has been replaced. 
(Main charger grid voltage adjustment)
1) Remove the rear cover of the machine. 
2) Apply a digital multi-meter to the connector CN2 pin (7) of the high
voltage PWB and the chassis GND.
3) Go through the modes specified in Simulation 8-1.
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Or after 30sec output.
SIMULATION 8-2
1
MAIN GRID SETTING. SELECT 1-6, AND PRESS START.
1.AUTO 
580
  2.CHARACTER 
580
3.MIX 
580
   4.PHOTO 
580
5.PRINTER 
580
  6.FAX 
580
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1.AUTO (200-1000)
580
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING···.
1.AUTO
580
ADJ 1B
Adjust the developing bias voltage
Item/operation mode
Simulation
High voltage power PWB (MC/DV/TC)
Setting range
Default
Adjustment voltage 
(monitor voltage)
Connector
Pin #
Actual 
voltage
Copy
Auto mode
8-1
AUTO
0 – 750
495
–500±5v
CN2
7
–500±5v
Text mode
CHARACTER
0 – 750
495
–500±5v
CN2
7
–500±5v
Text/photo mode
MIX
0 – 750
495
–500±5v
CN2
7
–500±5v
Photo mode
PHOTO
0 – 750
495
–500±5v
CN2
7
–500±5v
Printer
All modes
PRINTER
0 – 750
495
–500±5v
CN2
7
–500±5v
FAX
All modes
FAX
0 – 750
495
–500±5v
CN2
7
–500±5v
Cleaning mode
PLUS
0 – 250
150
+150±5v
CN2
7
+150±5v
CN2
7
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Or after 30sec output.
SIMULATION 8-1
1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO 
495
  2.CHARACTER 
495
3.MIX 
495
   4.PHOTO 
495
5.PRINTER 
495
  6.FAX 
495
  7.PLUS 
150
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1:AUTO (0-750)
495
SIMULATION 8-1
DV BIAS SETTING. EXECUTING···.
1:AUTO
495
AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 4
4) Select the number that corresponds to the adjustment item using
the numeric keypad.
5) Press the Start key. 
6) Press the start key to have the voltage output for 30 seconds. 
The operation can be stopped with the CUSTOM SETTINGS key. 
If the output voltage is not within the requirement, do the following
steps. 
7) Enter the adjustment value using the numeric keypad. 
8) Press the Start key
(The adjustment value is put into memory, and the corresponding
voltage is output for 30 seconds.) 
Repeat steps 7 to 8 until the output requirement is satisfied.
(Transfer voltage adjustment)
Transfer voltage adjustment (print operation mode)
This adjustment is needed in the following situations: 
• The high voltage power PWB (MC/DV/TC) has been replaced.
• U2 trouble has occurred. 
• The PCU PWB has been replaced.
• The EEPROM of the PCU PWB has been replaced. 
1) Go through the modes specified in Simulation 8-6.
2) Select the number that corresponds to the adjustment item
(FRONT/BACK) using the numeric keypad. 
3) Press the Start key
4) Enter the adjustment value (default) using the numeric keypad. 
5) Press the Start key
(The adjustment value is put into memory, and the corresponding
voltage is output for 30 seconds.) 
The operation can be stopped with the CUSTOM SETTINGS key.
Note: It is not possible to determine the adjusted transfer voltage
(print operation mode) (FRONT/BACK). If the voltage seems to
be abnormal after setting the default value, therefore, the high
voltage PWB (MC/DV/TC) should be replaced.
Transfer voltage adjustment (transfer belt cleaning mode)
This adjustment is needed in the following situations: 
• The high voltage power PWB (MC/DV/TC) has been replaced.
• U2 trouble has occurred. 
• The PCU PWB has been replaced.
• The EEPROM of the PCU PWB has been replaced. 
1) Remove the rear cover of the machine. 
2) Apply a digital multi-meter to the connector CN2 pin (1) of the high
voltage PWB and the chassis GND. 
ADJ 1C
Adjust the transfer voltage
Item/operation 
mode
Simulation
Adjustment voltage 
(monitor voltage)
Connector
Pin #
Actual voltage/actual 
current
Setting range
Default
Front print
8-6
FRONT
0 – 800
350
2.0 – 2.5Kv (35±1.0
µ
A)
High voltage 
power PWB 
(MC/DV/TC)
Back print
BACK
0 – 800
350
2.0 – 2.5Kv (35±1.0
µ
A)
Transfer belt 
(cleaning)
8-17
SHF FRONT
0 – 600
450
AC4.5Kv (p-p)
SHF BACK
0 – 600
450
AC4.5Kv (p-p)
THV-
0 – 75
10
DC -100±10v
CN2
1
DC -300±10v /
AC4.5Kv (p-p)
Transfer roller 
(cleaning)
8-18
CRHV PLUS
0 – 250
200
+2.0±0.1v
Check pin +2000±100v
High voltage 
power PWB 
(TC cleaning)
Transfer roller 
(print)
CRHV MINUS
0 – 250
200
–2.0±0.1v
Check pin –2000±100v
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Or after 30sec output.
SIMULATION 8-6
1
THV+ SETTING. SELECT 1-2, AND PRESS START.
1.FRONT 
350
2.BACK 
350
SIMULATION 8-6
THV+ SETTING. INPUT VALUE, AND PRESS START.
1.FRONT(0-800)
350
SIMULATION 8-6
THV+ SETTING. EXECUTING···.
1.FRONT
350
CN2
1
AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 5
3) Go through the modes specified in Simulation 8-17.
4) Select the number that corresponds to the adjustment item (SHF
FRONT / SHF BACK) using the numeric keypad. 
5) Press the Start key. 
6) Set each adjustment item to the default value (enter the adjust-
ment value and then press the Start key). 
Note: The adjustment items (SHF FRONT / SHF BACK) correspond
to the AC component of the 'transfer belt cleaning mode voltage'
applied to the transfer roller, but  this voltage component cannot
be determined. If the voltage seems to be abnormal after setting
the default adjustment value, therefore, the high voltage PWB
(MC/DV/TC) should be replaced.
7) Select the number that corresponds to cleaning operation mode
(THV-) using the numeric keypad.
Note: The adjustment items (THV-) corresponds to the DC component
of the 'transfer belt cleaning mode voltage' applied to the trans-
fer roller.
8)  Press the Start key. 
9) Press the Start key to have the voltage output for 30 seconds. 
If the output voltage is not within the requirement, do the following
steps. 
The operation can be stopped with the CUSTOM SETTINGS key. 
10) Enter the adjustment value using the numeric keypad. 
11) Press the Start key.
(The adjustment value is put into memory, and the corresponding
voltage is output for 30 seconds.) 
Repeat steps 10 to 11 until the output requirement is satisfied.
Transfer voltage adjustment (transfer roller cleaning/
transfer roller print modes)
This adjustment is needed in the following situations: 
• The high voltage power PWB (TC cleaning) has been replaced. 
• U2 trouble has occurred. 
• The PCU PWB has been replaced.
• The EEPROM of the PCU PWB has been replaced.
1) Connect the transfer section to the main body side using the trans-
fer extension harness (DHAi-3629FCZZ).
2) Remove the front frame cover of the duplex section, and remove
the rear frame cover of the transfer section.
3) Apply a digital multi-meter to the check pin of the high voltage
PWB (TC cleaning) and the chassis GND.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
SIMULATION 8-17
1
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1.SHV FRONT 
450
2.SHV BACK  
450
3.THV-  
30
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1.FRONT (0-600)
450
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING···.
1.FRONT(0-600)
450
Page of 44
Display

Sharp AR-M550 (serv.man14) Service Manual ▷ Download

  • DOWNLOAD Sharp AR-M550 (serv.man14) Service Manual ↓ Size: 2.46 MB | Pages: 44 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AR-M550 (serv.man14) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-M550 (serv.man14) Copying Equipment. Information contained in Sharp AR-M550 (serv.man14) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.