Sharp AR-M351U / AR-M451U (serv.man17) Service Manual ▷ View online
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 6
66
2
Used to clear the FAX soft switch function data
and to set to the default. (Excluding the
adjustment values.) (Only when FAX is installed)
and to set to the default. (Excluding the
adjustment values.) (Only when FAX is installed)
3
Used to check the operation of the FAX PWB
memory (read/write). (This adjustment is required
when the PWB is replaced with a new one.) (Only
when FAX is installed)
memory (read/write). (This adjustment is required
when the PWB is replaced with a new one.) (Only
when FAX is installed)
4
Used to check the output operation of data
signals in each data output mode of FAX. (Used
to check the operation of MODEM. ) Send level:
Max. (Only when FAX is installed)
signals in each data output mode of FAX. (Used
to check the operation of MODEM. ) Send level:
Max. (Only when FAX is installed)
5
Used to check the output operation of data
signals in each data output mode of FAX. (Used
to check the operation of MODEM.) An output is
sent at the send level set by the soft switch. (Only
when FAX is installed)
signals in each data output mode of FAX. (Used
to check the operation of MODEM.) An output is
sent at the send level set by the soft switch. (Only
when FAX is installed)
6
Used to print the confidential pass code. (Used
when the confidential pass code is forgotten.)
(Only when FAX is installed)
when the confidential pass code is forgotten.)
(Only when FAX is installed)
7
Used to print the image memory data (memory
send/receive). (Only when FAX is installed)
send/receive). (Only when FAX is installed)
8
Used to check the output operation of various
sound signals of FAX. (Used to check the
operation of the sound output IC.) Send level:
Max. (Only when FAX is installed)
sound signals of FAX. (Used to check the
operation of the sound output IC.) Send level:
Max. (Only when FAX is installed)
9
Used to check the output operation of various
sound signals of FAX. (Used to check the
operation of the sound output IC.) An output is
sent at the send level set by the soft switch. (Only
when FAX is installed)
sound signals of FAX. (Used to check the
operation of the sound output IC.) An output is
sent at the send level set by the soft switch. (Only
when FAX is installed)
10
Used to clear all data of the image memory
(memory send/receive). The confidential data are
also cleared at the same time. (Only when FAX is
installed)
(memory send/receive). The confidential data are
also cleared at the same time. (Only when FAX is
installed)
11
Used to check the output operation of FAX G3
mode 300bps. (Used to check the operation of
MODEM.) Send level: Max. (Only when FAX is
installed)
mode 300bps. (Used to check the operation of
MODEM.) Send level: Max. (Only when FAX is
installed)
12
Used to check the output operation of FAX G3
mode 300bps. (Used to check the operation of
MODEM.) An output is send at the send level set
by the soft switch. (Only when FAX is installed)
mode 300bps. (Used to check the operation of
MODEM.) An output is send at the send level set
by the soft switch. (Only when FAX is installed)
13
Used to enter (set) the number of FAX dial signal
output test. (The dial number set by this
simulation is outputted when the dial signal output
test is made by SIM 66-14 - 16. ) (Only when FAX
is installed)
output test. (The dial number set by this
simulation is outputted when the dial signal output
test is made by SIM 66-14 - 16. ) (Only when FAX
is installed)
14
Used to set the make time in the FAX pulse dial
mode (10pps) and to test the dial signal output.
(The dial number signal set by SIM 66-13 is
outputted.) Used to check troubles in dialing and
to check the operation. (Only when FAX is
installed)
mode (10pps) and to test the dial signal output.
(The dial number signal set by SIM 66-13 is
outputted.) Used to check troubles in dialing and
to check the operation. (Only when FAX is
installed)
15
Used to set the make time in the FAX pulse dial
mode (20pps) and to test the dial signal output.
(The dial number signal set by SIM 66-13 is
outputted.) Used to check troubles in dialing and
to check the operation. (Only when FAX is
installed)
mode (20pps) and to test the dial signal output.
(The dial number signal set by SIM 66-13 is
outputted.) Used to check troubles in dialing and
to check the operation. (Only when FAX is
installed)
16
Used to check the dial signal (DTMF) output in
the FAX tone dial mode. (The dial number signal
set by SIM 66-13 is outputted.) The send level
can be set to an optional level. Used to check
troubles in dialing and to check the operation.
(Only when FAX is installed)
the FAX tone dial mode. (The dial number signal
set by SIM 66-13 is outputted.) The send level
can be set to an optional level. Used to check
troubles in dialing and to check the operation.
(Only when FAX is installed)
Code
Function (Purpose)
Main
Sub
66
17
Used to check the dial signal (DTMF) output in
the FAX tone dial mode. Send level: Max. Used
to check the operation. (Only when FAX is
installed)
the FAX tone dial mode. Send level: Max. Used
to check the operation. (Only when FAX is
installed)
18
Used to check the dial signal (DTMF) output in
the FAX tone dial mode. An output is sent at the
send level set by the soft switch. Used to check
the operation. (Only when FAX is installed)
the FAX tone dial mode. An output is sent at the
send level set by the soft switch. Used to check
the operation. (Only when FAX is installed)
19
Used to back-up the HDD data into the Flash
memory (optional FAX expansion memory: AR-
MM9). (Only when FAX is installed)
memory (optional FAX expansion memory: AR-
MM9). (Only when FAX is installed)
20
Used to read the back-up data by SIM 66-19 to
the SRAM/HDD. (Only when FAX is installed)
the SRAM/HDD. (Only when FAX is installed)
21
Used to print information related to FAX (various
registrations, communication management, file
management, system error protocol). (Only when
FAX is installed)
registrations, communication management, file
management, system error protocol). (Only when
FAX is installed)
22
Used to adjust the handset volume. (Only when
the FAX is installed.)
the FAX is installed.)
23
Used to download the FAX program. (Only when
FAX is installed)
Not used in the market. (For development)
FAX is installed)
Not used in the market. (For development)
24
Used to clear the FAST memory data. (Only when
FAX is installed)
FAX is installed)
25
Used to register the FAX number for Modem dial-
in. (Only when FAX is installed)
Not used in the market. (For development)
in. (Only when FAX is installed)
Not used in the market. (For development)
26
Used to register external telephone numbers for
Modem dial-in. (Only when FAX is installed)
Not used in the market. (For development)
Modem dial-in. (Only when FAX is installed)
Not used in the market. (For development)
27
Used to register the transfer number for voice
warp. (Only when FAX is installed)
Not used in the market. (For development)
warp. (Only when FAX is installed)
Not used in the market. (For development)
29
Used to clear data related to an address book
(one-touch registration, program registration/
expansion, relay memory box registration, each
table content).
(one-touch registration, program registration/
expansion, relay memory box registration, each
table content).
30
Used to check the change in the TEL/LIU status.
(Only when FAX is installed)
(Only when FAX is installed)
31
Used to check the relay operation. (Only when
FAX is installed)
FAX is installed)
32
Used to check the receive data (fixed data) from
the line. (Only when FAX is installed)
the line. (Only when FAX is installed)
33
Used to check the signal (BUSY TONE/CNG/
CED/FNET/DTMF) detection. (Only when FAX is
installed)
CED/FNET/DTMF) detection. (Only when FAX is
installed)
34
Used to measure the communication time of test
image data. (Only when FAX is installed)
image data. (Only when FAX is installed)
35
Modem program rewriting. (Only when FAX is
installed) Not used in the market. (For
development)
installed) Not used in the market. (For
development)
36
Used to check interface between MFPC controller
and MDMC. (Check of the data line or the
command line) (Only when FAX is installed)
and MDMC. (Check of the data line or the
command line) (Only when FAX is installed)
39
Used to set the destination specifications. (Only
when FAX is installed)
when FAX is installed)
42
PIC program rewriting (Only when FAX is
installed)
installed)
43
PIC adjustment value writing (Only when FAX is
installed)
installed)
67
2
Used to check the operation of the parallel I/F of
the printer. (This simulation is for production only,
and requires a special tool for execution. Not
used in the market.)
the printer. (This simulation is for production only,
and requires a special tool for execution. Not
used in the market.)
11
Used to set YES/NO of the parallel I/F select
signal of the printer.
signal of the printer.
16
Used to check the operation of the network card.
Code
Function (Purpose)
Main
Sub
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 7
C. Details
Operation/Procedure
1) Select the operation mode with 10-key.
2) Press START key.
The scanner performs scanning at the speed corresponding to
the operation mode.
the operation mode.
Operation/Procedure
The sensor and detector operation conditions are displayed.
The active sensors and detectors are highlighted.
• The scanner (read) unit is in the home position.: "MHPS" section
is highlighted.
• The scanner (read) unit is not in the home position.: "MHPS" is
normally displayed.
Operation/Procedure
1) Select the operation mode with 10-key.
2) Press START key.
The SPF repeat paper feed, transport, and paper exit at the
speed corresponding to the operation mode.
speed corresponding to the operation mode.
The operation can be stopped by [CUSTOM SETTINGS] key.
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
played.
The active sensors and detectors are highlighted.
1
1-1
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the scanner
(read) unit and its control circuit.
(read) unit and its control circuit.
Section
Optical (Image scanning)
Item
Operation
1
TOP SPEED
Top speed (220mm/s)
2
HIGH SPEED
High speed (168.7mm/s)
3
MIDDLE SPEED
Middle speed (110mm/s)
4
LOW SPEED
Low speed (55mm/s)
Press [START] key, and the
operation is started.
operation is started.
Press [CUSTOM SETTINGS] key, and
scanning is stopped.
scanning is stopped.
1-2
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operation of sensor and
detector in the scanning (read) section and the
related circuit.
detector in the scanning (read) section and the
related circuit.
Section
Optical (Image scanning)
Item
Operation
MHPS
Optical system home position
SIMULATION 1-1
SCANNER CHECK. SELECT 1-4, AND PRESS START.
1. TOP SPEED
2. HIGH SPEED
3. MIDDLE SPEED
4. LOW SPEED
SCANNER CHECK. SELECT 1-4, AND PRESS START.
1. TOP SPEED
2. HIGH SPEED
3. MIDDLE SPEED
4. LOW SPEED
1
SIMULATION 1-1
SCANNER CHECK. EXECUTING···.
1. TOP SPEED
2. HIGH SPEED
3. MIDDLE SPEED
4. LOW SPEED
SCANNER CHECK. EXECUTING···.
1. TOP SPEED
2. HIGH SPEED
3. MIDDLE SPEED
4. LOW SPEED
1
SIMULATION 1-2
SCANNER SENSOR CHECK..
MHPS
2
2-1
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the automatic
document feeder unit and the control circuit.
document feeder unit and the control circuit.
Section
DSPF
Item
Operation
1
HIGH SPEED
High speed
2
LOW SPEED
Low speed
Press [START] key, and the
operation is started.
operation is started.
Press [CUSTOM SETTINGS] key, and
the operation is stopped.
the operation is stopped.
2-2
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the sensors and
detectors in the automatic document feeder unit
and the related circuits.
detectors in the automatic document feeder unit
and the related circuits.
Section
DSPF
Item
Operation
SPFSET
SPF sensor
SOCD
Open/close sensor
SCOV
Paper feed cover sensor
SPED
Document set sensor
SPPD
Resist front detection sensor
SPOD
Document paper exit sensor
SWDn
Document width sensor (n
→
1 (inside) - 6
(outside))
SPLSn
Document length sensor (n
→
1 (inside) - 2
(outside))
CISSET
CIS installation detection
STSET
Stamp unit installation sensor
SWD_LEN
SPF guide plate position (unit: 0.1mm)
SWD_AD
SPF document width detection volume output AD
value
value
SIMULATION 2-1
SPF AGING TEST. SELECT 1-2, AND PRESS START.
1. HIGH SPEED
2. LOW SPEED
2
SIMULATION 2-1
SPF AGING TEST. EXECUTING···.
1. HIGH SPEED
2. LOW SPEED
2
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 8
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press START key.
The load selected in procedure 1 is operated.
Press [CUSTOM SETTINGS] key to stop the operation of the load.
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
played.
The active sensors and detectors are highlighted.
• The following units are added when the punch unit is installed to
the console finisher:
2-3
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the loads in the
automatic document feeder unit and the control
circuits.
automatic document feeder unit and the control
circuits.
Section
DSPF
Item
Operation
1
MOTOR(H)
Motor high speed
2
MOTOR(L)
Motor low speed
3
SDSS
SPF gate solenoid
4
SPFS
SPF pick-up solenoid
5
SPFC
SPF paper feed clutch
6
SRRC
SPF resist roller clutch
7
STMPS
Stamp solenoid
Press [START] key, and the
operation is started.
operation is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped.
operation is stopped.
3
3-2
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operation of sensor and
detector in the finisher and the related circuit.
detector in the finisher and the related circuit.
Section
Finisher
Item
Operation
SIMULATION 2-2
SPF SENSOR CHECK.
SPFSET
SOCD
SCOV
SPED
SPPD SPOD
SWD6
SWD5
SWD4 SWD3 SWD2 SWD1
SPLS2 SPLS1
CISSET
STSET
SWD_LEN:
2100
SWD_AD:
600
SIMULATION 2-3
SPF LOAD TEST. SELECT 1-7, AND PRESS START.
1.MOTOR(H) 2.MOTOR(L)
3.SDSS 4.SPFS 5.SPFC 6.SRRC
7.STMPS
2
SIMULATION 2-3
SPF LOAD TEST. EXECUTING···.
1.MOTOR(H) 2.MOTOR(L)
3.SDSS 4.SPFS 5.SPFC 6.SRRC
7.STMPS
2
Built-in finisher
STHP
Stapler HP detection
POD
Tray 2 paper exit detection
SCID
Staple compiler paper entry detection
PID
Paper entry detection
T2PD
Tray 2 paper empty detection
T2DN
Tray 2 lower limit detection
T2UP
Tray 2 upper limit detection
JRHP
Jogger R HP
JFHP
Jogger (F) HP
SCID2
Staple compiler paper entry detection 2
STTHP2
Staple rotation HP detection 2
STTHP1
Staple rotation HP detection 1
STUHP
Staple shift HP detection
PSHP
Pusher HP detection
PPD
Paper hold return detection
DSW2
Staple replacement door open detection
DSW1
Compiler jam cancel door open detection
24VM
24V power supply
T1PF
Tray 1 full detection
STSP
Stapling ready detection
STLS
Cartridge inside spare staple empty detection
STNC
Cartridge empty detection
DOPD
Interface unit door open detection
MMLK
Main drive motor lock detection
SCPD
Staple compiler paper empty detection
Console finisher
FSSS
Stapler safety switch
FJS
Joint switch
FFDSW
Front door switch
FTCS
Upper cover sensor
FFDS
Front door sensor
FSPS
Self prime sensor
FSUC
Stapler connection detection
FSS
Staple sensor
FSTHPS
Stapler HP sensor
FSHPS
Slide HP sensor
FLE
Lift lock sensor
FLLLS
Lift lower limit sensor
FULS
Lift upper limit sensor
FFE
Bookbinding clock sensor
FFES
Bookbinding paper sensor
FFRHPS
Bookbinding roller HP sensor
FFHPS
Bookbinding HP sensor
FFPS
Bookbinding position sensor
FSLS
Paper surface sensor
FBES
Tray paper sensor
FOBHPS
Paper exit belt HP sensor
FAS
Alignment tray sensor
FRJHPS
Alignment HP sensor R
FFJHPS
Alignment HP sensor F
FARHPS
Bundle roller HP sensor
FPHPS
Paddle HP sensor
FES
Entry port sensor
FPE
Punch motor encoder
FPSHPS
Punch side register HP
FPUC
Punch connection detection
FPDS
Punch dust sensor
FPDSS4
Punch side register sensor 4
FPDSS3
Punch side register sensor 3
FPDSS2
Punch side register sensor 2
FPDSS1
Punch side register sensor 1
FPTS
Punch timing sensor
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 9
(Built-in finisher)
(Console finisher)
( ) : Added when the punch unit is installed.
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press START key.
The load selected in procedure 1 is operated.
Press [CUSTOM SETTINGS] key to stop the operation of the
load.
load.
Operation/Procedure
Enter the adjustment value with 10 digit key pad and press START
key. The jogger moves to LT position (Inch series) or A4 position
(AB series) according to the entered value, and stops there.
key. The jogger moves to LT position (Inch series) or A4 position
(AB series) according to the entered value, and stops there.
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key. (The entered value is stored.)
3-3
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operation of the load in the
finisher and the control circuit.
finisher and the control circuit.
Section
Finisher
Item
Operation
Built-in finisher
1
T2S
Tray 2 solenoid
2
T2OM
Paper exit motor
3
SPS
Stopper solenoid
4
SCRS
Roller pressure release solenoid
5
PPS
Rear edge h folding solenoid
6
SCGS
Compiler gate solenoid
7
STTM
Staple rotation motor
8
STUM
Stapler shift motor
9
MM
Main drive motor
10
EVM
Elevator motor
11
STM
Staple motor
12
JRM
Jogger motor rear
13
JFM
Jogger motor front
14
PSM
Pusher motor
Console finisher
1
FFC
Folding clutch
2
FPSM
Puncher side register motor
3
FPNM
Punch motor
4
FLM
Shift motor
5
FFSM
Stapler motor
6
FSM
Slide motor
7
FRJM
Alignment motor R
8
FFJM
Alignment motor F
9
FAM
Bundle exit motor
10
FPM
Paddle motor
11
FFM
Transport motor
SIMULATION 3-3
FINISHER SENSOR CHECK.
PID SCID SCID2 PPD
SCPD POD T1PF T2UP
T2DN T2PD STSP STLS
STNC STHP JFHP JRHP
PSHP STUHP STTHP1
STTHP2 DOPD DSW1 DSW2
24VM MMLK
SIMULATION 3-2
FINISHER SENSOR CHECK.
FSSS FJS FFDSW FTCS FFDS
FSPS FSUC FSS FSTHPS FSHPS FLE FLLLS
FULS FFE FFES FFRHPS FFHPS FFPS FSLS
FBES FOBHPS FAS FRJHPS FFJHPS FARHPS FPHPS
FES
(FPE)(FPSHPS)(FPUC)(FPDS)(FPDSS4)(FPDSS3)(FPDSS2)
(FPDSS1)(FPTS)
Press [START] key, and the operation
is started.
is started.
Press [CUSTOM SETTINGS] key, and
the operation is stopped.
the operation is stopped.
3-6
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust the stacking capacity of the
finisher. (Used to adjust the alignment plate
(jogger) stop position in the finisher paper width
direction. The adjustment is made by changing the
alignment plate home position in the paper width
direction by software.)
finisher. (Used to adjust the alignment plate
(jogger) stop position in the finisher paper width
direction. The adjustment is made by changing the
alignment plate home position in the paper width
direction by software.)
Section
Finisher
Item
Operation
Press [START] key, and the
operation is started.
operation is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped.
Stops when the operation is terminated.
operation is stopped.
Stops when the operation is terminated.
3-10
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Console finisher (AR-FN7) adjustment
Section
Finisher
Item
Operation
Item
Set
range
Initial
value
value
1STEP
1
Saddle binding position
adjustment
adjustment
0 - 400
200
0.0707mm
2
Saddle folding position
adjustment
adjustment
0 - 400
200
0.0525mm
3
Front alignment position
adjustment
adjustment
0 - 20
10
0.367mm
4
Rear alignment position
adjustment
adjustment
0 - 20
10
0.367mm
SIMULATION 3-3
FINISHER LOAD TEST. SELECT 1-
AND PRESS START.
2
SIMULATION 3-3
FINISHER LOAD TEST. EXECUTING
.
2
SIMULATION 3-6
FINISHER JOGGER ADJUSTMENT. INPUT VALUE 40-60, AND PRESS START.
50
SIMULATION 3-6
FINISHER JOGGER ADJUSTMENT. MOVING....
50