Sharp AR-M351U / AR-M451U (serv.man11) Service Manual ▷ View online

AR-M351U/M451U, AR-M355U/M455U  MAINTENANCE AND DETAILS OF EACH SECTION  7 - 8
D. Maintenance and parts replacement
(1) Maintenance list
(2) Maintenance and parts replacement
a. Drum cartridge
1) Release the lock, and pull out the left door.
2) Open the front door.
3) Put down the DV guide handle. Loosen the screw, and remove
the drum cartridge. 
Unit name
No.
Part name
When 
calling
100K 200K 300K 400K 500K 600K 700K 800K
Remark
Drum 
peripheral
1
Drum
Replace at 200K or 1 year.
2
DSD  collar
3
Cleaner blade
4
Toner reception seal
5
Side molt F
Apply side seal powder.
6
Side molt R
Apply side seal powder.
7
Drum separation pawl unit
8
MC unit
Includes the screen grid, the 
charging plate, and the MC 
cleaner. 
: Charging plate cleaning by 
the MC cleaner
1
7
2
4
6
2
5
3
8
No.
Unit
Parts
a
Drum cartridge
1
MC unit
×
2
Drum
3
DSD  collar
4
Drum separation pawl unit
×
5
Toner reception seal
×
6
Cleaner blade
×
7
Side molt F
×
8
Side molt R
×
b
1
Separation solenoid
a-2
a-4
a-3
a-7
a-6
a
a-1
a-3
b-1
a-5
a-8
AR-M351U/M451U, AR-M355U/M455U  MAINTENANCE AND DETAILS OF EACH SECTION  7 - 9
a-1. MC unit
1) Remove the drum cartridge.
2) Check to confirm that the cleaning unit is inserted fully to the
bottom. 
3) Remove the pawl, and remove the MC unit. 
For cleaning the MC unit (charging plate), reciprocate the clean-
ing unit back and forth 3 times or more.
a-2. Drum
a-3. DSD collar
1) Remove the drum cartridge.
2) Loosen the screw, and remove the drum boss mounting plate.
3) Remove the drum, and remove the DSD collar.
When removing the drum, place the drum cartridge as shown in
the figure and remove the drum.
When replacing the OPC drum, clear the following counters.
• Drum rotating time
• Drum counter
When installing a new drum, apply starting powder.
When installing, install the DSD collar R to the drum frame, then
install the drum and the DSD collar F. When installing the DSD
collar, engage the DSD collar boss with the drum frame hole.
a-4. Drum separation pawl unit
1) Remove the drum cartridge.
2) Remove the screw, and remove the drum separation pawl
unit.
When handling the separation pawl, be careful not to break or
scratch the tip of the separation pawl and keep it away from dirt. 
After installing the drum separation pawl unit, push the separation
lever and check to confirm that the separation pawl operates nor-
mally.
a-5. Toner reception seal
1) Remove the drum cartridge.
2) Remove the drum and the DSD collar.
3) Remove the drum separation pawl unit.
4) Remove the screw, and remove the toner reception seal.
When installing the toner reception seal, tighten the screw (a)
on the positioning side for the first time. Check to confirm that
the process earth plate and the toner reception seal are conduc-
tive. (10
 or less)
(a)
AR-M351U/M451U, AR-M355U/M455U  MAINTENANCE AND DETAILS OF EACH SECTION  7 - 10
a-6. Cleaner blade
1) Remove the drum cartridge.
2) Remove the drum and the DSD collar.
3) Pull it out until the cleaning unit stops.
4) Remove the screw, and remove the cleaner blade.
When removing the drum blade, place the drum as shown in the
figure and remove the drum blade to prevent toner from dispers-
ing.
Do not damage the cleaner blade. Do not touch the lead edge.
When installing the cleaner blade, pull the cleaner shaft fully
toward you.
After installing the cleaner blade, insert the cleaner shaft fully to
the bottom.
a-7. Side molt F
a-8. Side molt R
1) Remove the drum cartridge.
2) Remove the drum and the DSD collar.
3) Remove the toner reception seal.
4) Remove the cleaner blade.
5) Remove the side molt F and R.
When attaching the side molts F/R, attach them to the attach-
ment reference as shown.
After attaching the side molt F/R, push the both ends of the
blade with your fingers to check to confirm that the red moquette
moves smoothly.
Put side seal powder (1g) on the moquettes F/R and spread side
seal powder all over the moquettes surfaces.
Side seal powder: UKOG-0309FCZZ
Do not apply powder excessively to the ambient parts.
Be careful not to damage the cleaning blade and the side blade. 
b-1. Separation solenoid
1) Remove the screw, and remove the rear cabinet.
Reference
Reference
0.3mm
0mm
0mm
0.3mm
Side molt F
0.3mm
Reference
Reference
0mm
0.1mm
0.5mm
(From the blade edge)
0.1mm
Side molt R
AR-M351U/M451U, AR-M355U/M455U  MAINTENANCE AND DETAILS OF EACH SECTION  7 - 11
2) Remove the connector and the screw, and remove the PCU
PWB unit.
3) Remove the screw and the connector, and remove the sepa-
ration solenoid unit.
4) Remove the E-ring and the screw, and remove the separation
solenoid.
[Transfer section]
A. General
In this section, toner images on the OPC drum are transferred to
paper.
B. Major parts and signal functions