Sharp AR-M35 / AR-M450 (serv.man7) Handy Guide ▷ View online
Test Simulation
Version 2.0
Issue 01/02
16
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
AR-M350/450
Test
Command
Sub Code
Default
Setting
Setting
Description
10
--
Toner motor activation
14
--
Trouble cancel U1/LOC/U2/PF troubles).
15
--
U4-09/20/21/22 LCC trouble cancel
16
--
U2 trouble cancel
17
--
Cancel copy inhibition by host computer during self diag PF
21
01
Maintenance cycle setting
22
--
Counter information displays
01
Counter data display
02
Jam/trouble counter display
03
Jam history data display
04
Trouble history data display
05
ROM version display
06
Data print mode
07
Key operator code display
08
Original/stapler counter display
09
Paper feed counter display
10
Machine system display
12
DF jam history display
13
Process Cartridge Data
19
Scanner mode counter
24
--
Clears special counters
01
Jam/trouble counter clear
02
Paper feed counter clear
03
Original/stapler counter clear
04
Maintenance counter clear
05
Developer counter clear
06
Copy counter clear
07
Drum correction counter clear
09
Printer/other counter clear
10
Fax mode counter clear
11
Reset developer time counter
15
Scanner counter clear
25
01
Checks the activation of main motor drive unit
26 --
Settings
03
Auditor set up
05
2
Total/Maintenance counter set up
06
Destination set up
10
Network scanner trial mode
26
18
Used to set toner save operations
30
CE mark setting
35
0
Trouble memory mode setting
41
Used to disable/enable auto magnification
50
Enable /disable white paper count -up
27
Communications set up
01
To Communications specifications
Sets machine tag number
30
--
Main body sensors
Test Simulation
Version 2.0
Issue 01/02
17
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
AR-M350/450
Test
Command
Sub Code
Default
Setting
Setting
Description
01
Main unit sensor check
30
02
Tray sensor check
40
--
Bypass tray sensor check
01
Bypass tray size sensor check
02
Bypass tray adjustment
07
Bypass width detection level set up
11
Bypass width detection check
12
Bypass width detection adjust (Multi-Purpose Tray)
41
--
Original size detection (OC mode)
01
PS sensor check
02
PS sensor adjustment
03
PS sensor output display
43
01
Fuser temperature set up
44
--
Process control mode
01
Correction mode setting
04
PC initial density set up (drum type B)
09
PC data display
46 --
Exposure
adjustment
02
Adjust copy density in copy mode
09
Adjust print density in copy/text mode
10
Adjust print density in copy/text/photo mode
11
Adjust print density in copy/photo mode
12
Adjust print density in fax mode ( all modes)
13
Adjust print density in fax mode (normal)
14
Adjust print density in fax mode (small text)
15
Adjust print density in fax mode (fine text)
16
Adjust print density in fax mode (super-fine)
17
Adjust shading correction
18
Adjust gamma density gradient in copy mode
19
Adjust gamma in auto copy mode
46
20
Adjust copy density in DSPF
21
Adjust scanner exposure level 1 mode auto
22
Adjust scanner exposure level normal
23
Adjust scanner exposure level small text
24
Adjust scanner exposure level fine mode
25
Adjust scanner exposure level super-fine
48 01
Magnification
adjustment
05
Adjust exposure motor speed
50
--
Lead edge registration
01
Lead edge adjustment value (copy)
02
Lead edge adjustment value (calculation)
06
50
Lead edge adjustment DSPF
07
50
Lead edge adjustment DSPF (simple)
10
50
Print centre deviation adjustment.
12
50
Original centre deviation adjustment.
51
02
50
Resist roller adjustment value
53
--
Document Feeder adjustments
06
Adjusts DSPF width detection
Test Simulation
Version 2.0
Issue 01/02
18
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
AR-M350/450
Test
Command
Sub Code
Default
Setting
Setting
Description
07
Value entry for DSPF width detection
60 01
DRAM
test
61
--
Laser unit
01
Scanner operational check
02
Adjust scanner laser power in copy mode
03
Adjust scanner laser power in fax mode
04
Adjust scanner laser power in print mode
62 --
Hard
drive
02
HDD read/write test partial check
03
HDD read/write test all area check
63
01
CCD shading data display
02
Executes
shading
07
Adjust the white plate scanning start position
64 01
Self
print
65 --
Touch
panel
01
Touch panel adjustment
02
Touch panel test
66
--
Fax soft switches
67
02
Printer Parallel I/F operation check
11
Used to set printer I/F select in signal
67
16
Used to check the operation of the network card
Test Simulation
Version 2.0
Issue 01/02
19
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
AR-P350 Diagnostic Mode Notes.
Diagnostic Mode Entry
When the scanner unit is not installed, the machine can be checked and tested with the following diagnostics mode.
To cancel diagnostic mode, turn the power off.
Hold
the
MENU
and OK keys down whilst turning on the main power switch.
Machine Data Print
1. In diagnostic mode press MENU 12 times to display Test print 00
2.
2.
Press OK. The machine will enter warm up mode with no indication on the display.
3. Multi setting.
Use
tuto select the number of copies required.
4. MENU
. Print pattern. Use
tuto select the test pattern required.
PP1
Centre line for centre alignment checks
PP2
Half tone full page coverage for image loss checks.
PP65 Pattern test for laser focus checks.
PP66 Laser write pattern
PP67 Laser write pattern
PP68 Laser write pattern
PP70 Alignment scale test chart
PP71 All square pattern
PP72 Diagonal
PP66 Laser write pattern
PP67 Laser write pattern
PP68 Laser write pattern
PP70 Alignment scale test chart
PP71 All square pattern
PP72 Diagonal
pattern
PP73 Diagonal
pattern
PP74 Diagonal
pattern
PP75 ID patch print
PP87 Sharp test sheet B
PP88 Ageing chart 6% toned area
PP89 Ageing chart 5% toned area
PP98 Machine data print out (SIM 22 – 06)
PP87 Sharp test sheet B
PP88 Ageing chart 6% toned area
PP89 Ageing chart 5% toned area
PP98 Machine data print out (SIM 22 – 06)
5. MENU. Cassette. Use
tuto select the paper source. (Note BPT = MFT)
6. MENU. Duplex. Use
tuto select Duplex mode.
7. MENU. Output. Use
tuto select the type of output dependent on the options fitted .
8. Press
OK
for test prints.
Note: If the scanner unit is installed this mode does not work.
Notes
A)
The OK key can be pressed at any time for the machine to produce a test print. However, if OK is pressed
and the data light remains flashing and no print is produced check the type of output selected. It may be
that the optional unit required for that type of output is not installed. For example BIN # selected with no
AR-MS1 installed.
that the optional unit required for that type of output is not installed. For example BIN # selected with no
AR-MS1 installed.
B)
Pressing the Information key will return to the previous Menu item.
For example, return from Output to Duplex press INFORMATION.
C) Pressing
BACK/C
to the main menu item.
For example, in Output press BACK/C returns to Test Print 0