DOWNLOAD Sharp AR-M35 / AR-M450 (serv.man37) Service Manual ↓ Size: 100.29 KB | Pages: 6 in PDF or view online for FREE

Model
AR-M35 AR-M450 (serv.man37)
Pages
6
Size
100.29 KB
Type
PDF
Document
FAQ
Brand
Device
Copying Equipment / Procedure to convert machines using AR450DM (50K Drum) to AR451DM (100K Drum). (Corrected)
File
ar-m35-ar-m450-sm37.pdf
Date

Sharp AR-M35 / AR-M450 (serv.man37) FAQ ▷ View online

           Page 4 of 6
Hold down the Menu key and the OK Key and turn the power on.
The display should read “PCU DIAG MODE”.
The display will blink once then stabelize.
Press the menu key 7 times.
The display should read “LASER POWER SET (AE)”.
Press the “OK” Key.
Use the UP/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
Press the “Back/C” Key then press the down arrow.
The display should read “LASER POWER SET (FAX)”.
Press the “OK” Key
Use the Up/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
Press the “Back/C” Key then press the down arrow.
The display should read “LASER POWER SET (PRT)”.
Press the “OK” Key.
Use the UP/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
Press the “Back/C” Key then press the down arrow.
The display should read “LASER POWER SET (PHT)”.
Press the “OK” Key.
Use the UP/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
Press the “Back/C” Key then press the down arrow.
The display should read “LASER POWER SET (MIX)”.
Press the “OK” Key.
Use the UP/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
Press the “Back/C” Key then press the down arrow.
The display should read “LASER POWER SET (CHR)”.
Press the “OK” Key.
Use the UP/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
        Page 5 of 6
Press the “Back/C” Key.
Press the “Menu” Key 15 times.
The display should read “MNT CYCLE SET”.
Press the “OK” Key.
Use the UP/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
Press the “Back/C” Key.
Press the “Menu” Key 1 time.
The display should read “LIFE OVER SETTING”.
Press the “OK” Key.
Use the UP/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
Press the “Menu” Key 9 times.
The display should read “PROCESS SETTING”.
Press the “OK” Key.
Use the UP/Down Arrows to change the value to the one shown on the chart.
Press the “OK” Key to set the new value into memory.
Press the “Back/C” Key.
Turn the machine Off/On.
3) 
The 100K Drum (AR-451DR) must be installed in the machine.
The AR-451DR can be identified by a white mark on the rear side flange
and by the aluminum base being slightly exposed on the front side as
shown in the pictures below.
     Page 6 of 6
4) 
The 100K Drum Seperation Pawls included in the AR-451DR must be
installed in the machine.
The new style Drum Seperation Pawls can be identified by a white mark as
shown in the picture below.
Note: Initially the new style Drum Seperation Pawls will only be included in the package
of the AR-451DR.  A new part (DUNT-0038YSZZ) includes four pawls in a pack.
Do not use the old style Drum Seperation Pawls included in the AR-450KC kit.
Using the old style Drum Seperator Pawls will reduce the life of the 100K Drum.
The new style Drum Seperation Pawls will be included in the AR-450KC from
June 2002 production.
Important:
It is highly recommended that the developer also be replaced at the time of
adopting the AR-451DR 100K PM Cycle so that the drum and developer
maintenance cycles coencide with each other. If the machine is in the middle of
its developer life cycle, you may elect to use the 50K drum untill the developer life
is over. At that time you may change to the 100K PM cycle. If no 50K drums are
available to you, it is recommended that you replace the DV when changing to the
100K PM cycle.
 To change from the 100K PM Cycle to the 50K PM Cycle, change all the settings
in step 2 to the 50K settings and install the 50K Drum and Drum Seperation
Pawls.
     Page 6 of 6
4) 
The 100K Drum Seperation Pawls included in the AR-451DR must be
installed in the machine.
The new style Drum Seperation Pawls can be identified by a white mark as
shown in the picture below.
Note: Initially the new style Drum Seperation Pawls will only be included in the package
of the AR-451DR.  A new part (DUNT-0038YSZZ) includes four pawls in a pack.
Do not use the old style Drum Seperation Pawls included in the AR-450KC kit.
Using the old style Drum Seperator Pawls will reduce the life of the 100K Drum.
The new style Drum Seperation Pawls will be included in the AR-450KC from
June 2002 production.
Important:
It is highly recommended that the developer also be replaced at the time of
adopting the AR-451DR 100K PM Cycle so that the drum and developer
maintenance cycles coencide with each other. If the machine is in the middle of
its developer life cycle, you may elect to use the 50K drum untill the developer life
is over. At that time you may change to the 100K PM cycle. If no 50K drums are
available to you, it is recommended that you replace the DV when changing to the
100K PM cycle.
 To change from the 100K PM Cycle to the 50K PM Cycle, change all the settings
in step 2 to the 50K settings and install the 50K Drum and Drum Seperation
Pawls.
Page of 6