Sharp AR-M150 Handy Guide ▷ View online
Consumables
Version 1.0
Issue April 2004
9
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
Consumable System
For AR-M150 / AR-M155
The AR-M150 / AR-M155 consumable system is SRU – Service Replaceable Units.
The Toner unit is supplied as a cartridge that the end user replaces. The Drum and
Developer are replaced by a service engineer when required.
The Toner unit is supplied as a cartridge that the end user replaces. The Drum and
Developer are replaced by a service engineer when required.
Model Life*
Toner Cartridge
AR152LT (10)
Approx. 8,000 sheets**
Developer
AR152LD (10)
Approx. 25,000 sheets
Drum AR152DM
Approx.25,000
sheets
* Based on A4 sheet @ 6% coverage
** The initial cartridge supplied with the machine has a life of approx. 2,000 sheets.
** The initial cartridge supplied with the machine has a life of approx. 2,000 sheets.
Maintenance Display
Life 8K
Remaining quantity
Remaining quantity
NEAR EMPTY
About 10%
About 10%
EMPTY
LED ON
Flash
Toner
Machine Operation
allowed
Stop
Life 25K
LED
LED
ON at 25K of developer
count
count
Developer
Machine
Selection is from Not Stop to Stop by SIM 26-37
(If Stop is selected, the LED will flash and stop at
25K)
Default : Not Stop
Clear : SIM 20-1
(If Stop is selected, the LED will flash and stop at
25K)
Default : Not Stop
Clear : SIM 20-1
LED
Selection is from 25K,13K,9K,6K,3K and Free (no
lighting) with SIM 21-1.
Default : 25K
Clear : SIM 20-1
lighting) with SIM 21-1.
Default : 25K
Clear : SIM 20-1
Maintenance
Machine Not
Stop
Maintenance
table
{
: Clean
5 : Replace
Section
Parts 25K
50K
75K
100K
125K
Developer
t
t
t
t
t
DV blade
{
t
{
t
{
Developing
DV side seal
(F/R)
(F/R)
{
t
{
t
{
Process Peripheral
Drum
t
t
t
t
t
Test Simulation Codes
Version 1.0
Issue April 2004
10
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
Simulation Codes
The following pages contain information regarding Test simulations.
The specification of the particular model involved and the peripherals which are
installed will determine which simulation/error codes will be operative.
Entering Test Command Mode
On the copier operation panel press the following keys:
[ # ] → [ * ] → [ C ] → [ * ]
Key Rule
[ 10 KEY ]:
Entry of Main Code / Sub Code
Selection of an item
Setup
of
an
adjustment
value
[←/→]:
Selection of Main Code / Sub Code
Selection of an item
[ENTER / START] Settlement
<
in
case
of
test commands for print >
[ENTER]:
Settlement
(Without
print)
[START]:
Settlement
/
Print
[C]:
(Interrupting operation check) Returns to the upper hierarchy
[CA]:
Exit from Test Command mode
Test Simulation Codes
Version 1.0
Issue April 2004
11
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
Main
Code
Sub
Code
Contents
01
Mirror scan (SCAN CHK)
02
Mirror home position sensor (MHPS) status display
1
06 Mirror
scan
aging
01 SPF
aging
02
SPF sensor status display
03
SPF Motor operation check
06
RSPF resist clutch operation check
08
SPF paper feed solenoid operation check
09
RSPF reverse solenoid operation check
2
10
RSPF paper exit gate solenoid operation check
3 03
Shifter
operation
check
01
Operation panel display check
02
Fusing lamp cooling fan operation check
5
03
Copy lamp ON check
01
Paper feed solenoid operation check
6
02
Resist roller solenoid operation check
01
Check of warm-up display and aging with JAM
06 Interval
aging
7
08
Shift to copy with warm-up display
01
Developing bias output
02
Main charger output (Grid HIGH)
03
Main charger output (Grid LOW)
8
06
Transfer charger output
9
01
Duplex motor normal rotation check
02
Duplex motor reverse rotation check
04
Duplex motor rotating speed adjustment
10
00
Toner motor operation check
14
00
Cancel of trouble other than U2
16
00
U2 trouble cancel
20
01
Maintenance counter clear
21
01
Maintenance counter setting
01
Maintenance counter display
02
Maintenance preset display
04
JAM total counter display
05 Total
counter
display
06 Developer
counter display
08
SFP counter display
11
FAX related counter display
12
Drum counter display
22
13 CRUM
type
display
Test Simulation Codes
Version 1.0
Issue April 2004
12
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
14
ROM version display
16
Duplex counter display
17 Copy
counter
display
18 Printer
counter display
19
Scanner mode counter display
21
Scanner counter display
22
22
SPF jam counter display
01
JAM total counter clear
04
SPF counter clear
05
Duplex counter clear
06
Developer counter clear
07
Drum copy counter clear
08 Copy
counter
clear
09
Printer counter clear
10
Fax counter clear
13
Scanner counter clear
14
SPF jam counter clear
24
15
Scanner mode counter clear
01
Main motor operation check
25
10
Polygon motor operation check
02 (R)SPF
setting
03 Second
cassette setting
04
Main unit duplex setting
06 Destination
setting
07 Machine
conditions
check
20
Rear edge void setting
30
CE mark support control
37
Cancel of stop at developer life over
39
Memory capacity check
40
Polygon motor off time setting
42
Transfer ON timing control setting
43
Side void amount setting
26
62
Energy-save mode copy lamp setting
30
01
Paper sensor status display
41
06
OC cover float detection level
01
Fusing temperature setting (Normal copy)
04
Fusing temperature setting in multi-copy
05
Fusing temperature setting in duplex copy
43
14
Fusing start temperature setting
01
Copy density adjustment (300 dpi)
02
Copy density adjustment (600 dpi)
12
Copy density adjustment in FAX mode
46
13
FAX mode density adjustment (normal text)