DOWNLOAD Sharp AR-LC1 (serv.man2) Service Manual ↓ Size: 843.46 KB | Pages: 30 in PDF or view online for FREE

Model
AR-LC1 (serv.man2)
Pages
30
Size
843.46 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARLC1 Service Manual
File
ar-lc1-sm2.pdf
Date

Sharp AR-LC1 (serv.man2) Service Manual ▷ View online

2. Mount the connecting plate to the large capacity tray.
Note: Before mounting the connecting plate to the large capacity
tray, be sure to remove the 2 step screws for securing the
bottom plate.
Fit the connecting plate to the lower part of the large capacity tray
and mount the plate to the position indicated with A using screw B.
3. Fit the connecting plate of the large capacity tray to
the mounting plate of the stand.
Insert the connecting plate into the mounting plate of the stand while
lifting the large capacity tray a little.
After insertion, move the large capacity tray away from the copier to
check that the tray is locked.While the tray is locked, mount the
securing plate using 2 screws C.
4. Check and adjust the height of the large capacity tray.
Move the large capacity tray toward the copier and adjust the tray
and check it so that the rib of the large capacity tray is flush with the
axis of the mounting plate which has been mounted to the copier as
shown in the figure.
If the axis is flush with the rib:
Push the large capacity tray toward the copier.
If the axis is not flush with the rib:
Loosen the 2 screws of the installation adjuster mounting plate lo-
cated at the lower part of the large capacity tray and adjust as fol-
lows:
 If the rib is to the right of the axis 
Turn the knob clockwise to adjust.
After adjustment, tighten the 2 screws of the installation adjuster
mounting plate.
 If the rib is to the left of the axis 
Turn the knob counterclockwise to adjust.
After adjustment, tighten the 2 screws of the installation adjuster
mounting plate.
‚`
‚a
‚`
‚a
Screw B 
Step screws 
Connecting plate 
1
2
 Mounting plate 
Connecting plate 
Securing plate 
Screws C 
Top view
 
Axis
Rib
Top view
Axis
Rib
Knob
Screw
Top view
Axis
Rib
Knob
 
Screw
3 – 2
5. Connect the connector of the large capacity tray.
Remove the connector cover securing screw for connection of the
large capacity tray relay harness connector and remove the connec-
tor cover.Then connect the large capacity tray relay harness connec-
tor to the connector of the copier and tighten the screw on the con-
nector to secure the connector.
6. Remove the feed table securing screw and securing
materials.
Pull out gently the paper tray of the large capacity tray until it
stops.Remove the feed table securing screw and 5 securing materials
which secure the feed table of the large capacity tray.
Push back gently the paper tray to its original position.
To use the large capacity tray without changing the paper size from
the factory default setting:
Proceed to step 12 of this installation manual.
At this time, insert the power plug of the copier to an outlet and turn
the power switch to the "ON" position.
Factory default setting: A4 size
The paper size can be switched only to the B5 size.
To use the large capacity tray after changing the paper size from the
factory default setting:
7. Remove the stopper from the paper tray.
Pull out gently the paper tray until it stops and remove the stopper
securing screw located on the lower part of the right side to remove
the stopper.
Then pull out again the paper tray until it stops.
8. Switch the rear end shaft.
Remove each rear end shaft securing screw (blue) which secures the
rear end shaft to the right side in the paper tray and remove the 2
rear end shafts.
Then fit the lower part of each removed rear end shaft to the mount-
ing hole of the feed table of the paper tray and secure the upper part
to the position with B5 indication using a securing screw (blue).
Securing screw
Connector cover
 Screw
Connector
Securing materials
Securing materials
Feed table securing screw
Feed table
Stopper
Securing screw
Rear end shafts
Securing screw (blue)
Securing screw (blue)
Securing screw (blue)
Rear end shafts
Feed table
 Mounting holes
3 – 3
9. Switch the size of side plates F and R
Remove the screws which secure the upper and lower parts of side
plates F and R and remove side plates F and R.
Then fit the lower parts of side plates F and R to the position with B5
indication, position also the upper parts to the B5 size position, and
secure the plates using two screws (blue) for each plate.
10. Mount the stopper of the paper tray.
Push in the paper tray a little, mount the stopper which has been
removed in step 9, and secure it using the screw. At this time, check
that the pawl of the stopper is caught by the stopper block of the large
capacity tray.
Then push back gently the paper tray to its original position.
Paper size switching is complete here.
Insert the power plug of the copier to an outlet,
turn the power switch to the "ON" position and
then perform the following procedure.
11. Register the paper size.
Register the paper size with the key operation of the copier.
The LCC size selection window will be displayed in the message
display with the operation above.
Select the number of the size to be registered in the message dis-
play, enter the number using the keys on the operation panel and
press the  OK  key to register it.
Then turn the power switch to the "OFF" position and then to the
"ON" position again.
12. Adjust the center position.
Since adjustment has been made at shipment, adjustment is basically
not needed. However, if the center should be displaced, adjust it
using the procedure below.
Make a copy. If the center is displaced as shown in Fig. 1 or Fig. 2,
pull out gently the paper tray until it stops.
Then, loosen the 2 screws at portion a which secure the tray lock
plate and the 8 screws at portion b (right and left sides) which secure
the tray cover unit to the frame and adjust the center position using
the procedure below.
Side plate R
Screws (blue)
Screws (blue)
Side plate F
Stopper block
Pawl
Stopper
 Screw
2
6
2
C
P
Left side
Right side
Portion b
Portion a
Tray cover unit
Portion a
Direction A
Direction B
 Scale (pitch in mm)
Tray lock plate
Portion b
3 – 4
In case of Fig. 1:
Move the tray lock plate in direction A by the length of displacement,
tighten the 2 screws at portion a and then the 8 screws at portion b,
and make a copy again to check that the center is not displaced.
In case of Fig. 2:
Move the tray lock plate in direction B by the length of displacement,
tighten the 2 screws at portion a and then the 8 screws at portion b,
and make a copy again to check that the center is not displaced.
 Fig. 1
Center line of paper
Center of image (first image)
Center line of paper
Center of image (first image)
Fig. 2
3 – 5
Page of 30
Display

Sharp AR-LC1 (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sharp AR-LC1 (serv.man2) Service Manual ↓ Size: 843.46 KB | Pages: 30 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AR-LC1 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-LC1 (serv.man2) Copying Equipment. Information contained in Sharp AR-LC1 (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.