Sharp AR-FX7 Service Manual ▷ View online
AR-FX7 SPECIFICATIONS 2 - 4
9.
Memory system
10. Additional information function for
transmission
11. Additional print function when
receiving
12. Recording table system
(1) Communication record function
(2) Communication result report function
Transmission complete sound
tone setup (transmission end)
tone setup (transmission end)
YES (Set by key operator program
to PATTERN 1/2/3.)
to PATTERN 1/2/3.)
Transmission complete sound
tone setup (reception end)
tone setup (reception end)
YES (Set by key operator program
to PATTERN 1/2/3.)
to PATTERN 1/2/3.)
Transmission complete sound
time setup
time setup
YES (Set by key operator program.
2.0/2.5/3.0/3.5/4.0 sec.)
2.0/2.5/3.0/3.5/4.0 sec.)
Scan end sound
YES (Set by soft switch.)
Tone pulse switch
Cancel tone/pulse switch set by the
key operator program.
Set with the service switch.
key operator program.
Set with the service switch.
External telephone
connection
connection
YES
Remote
reception switch
reception switch
YES (Switch number is in 1 digit +
∗∗
) 5
∗∗
Telephone/
Fax
Fax
Sound
response
response
NO
Answering
voice recording
voice recording
NO
Memory capacity
Standard
2MB
Option
8MB
Memory content
(transmission
reservation)
confirmation
(transmission
reservation)
confirmation
LCD display
YES
Printout
YES
Memory use status
YES (% display)
Document data memory backup
in power failure
in power failure
YES (Flash memory)
Page counter
YES
Date printing
YES (day/month/year/the day of
week, year is in 4 digits)
week, year is in 4 digits)
Date/ display sequential
switch
switch
NO
Cover
paper item
paper item
Date
YES
Receiver’s
name
name
YES
Receiver’s
number
number
YES
Sender’s
name
name
YES
Sender’s
number
number
YES
Display of
number of
documents
transmitted
number of
documents
transmitted
YES
Transmission
message
message
YES
Print paper
size
size
A4
Transmission message
(Regular message)
(Regular message)
(U.K.)
CONFIDENTIAL/PLEASE.
DISTRIBUTE/URGENT/PLEASE
CALL BACK/IMPORTANT
CONFIDENTIAL/PLEASE.
DISTRIBUTE/URGENT/PLEASE
CALL BACK/IMPORTANT
(France)
COFIDENTIEL/
VEUILLEZ DISTRIBUER
URGENT
VEUILLEZ RAPPELER
IMPORTANT
COFIDENTIEL/
VEUILLEZ DISTRIBUER
URGENT
VEUILLEZ RAPPELER
IMPORTANT
(Germany)
VERTRAULICH
BITTE VERTEILEN
EILIG
BITTE RÜCKRUF
WICHTIG
VERTRAULICH
BITTE VERTEILEN
EILIG
BITTE RÜCKRUF
WICHTIG
Sender print
NO
User message
NO
Index print
YES (Set by key operator program)
Communication record
table size
table size
A4 (Not output when paper larger than
A5 is not set.)
A5 is not set.)
Communication record
memory capacity
memory capacity
50 items in total of transmission and
reception
reception
Communication record
table
table
Max. 50 items for each of transmission
and reception (Total of transmission and
reception is up to 50 items.) Record table
is outputted separately. If registration
exceeds 50, the oldest one is deleted.
and reception (Total of transmission and
reception is up to 50 items.) Record table
is outputted separately. If registration
exceeds 50, the oldest one is deleted.
Time-specified output
YES (1 time per day)
Output when
recording memory full
recording memory full
YES (Print/not print is set by key
operator)
operator)
Output of individual
department
department
YES (Communication time of each
department is outputted as department
management record table.)
department is outputted as department
management record table.)
Time-specified
communication table
communication table
Common with transmission record table
Confidential reception
check table
check table
YES
Commu-
nication
result
table
nication
result
table
Single sending
YES (Print out all report/Print out
error report only/No printed report.
With key operator program)
error report only/No printed report.
With key operator program)
Broadcast
communication
report
communication
report
YES (Print out all report/Print out
error report only/No printed report.
With key operator program)
error report only/No printed report.
With key operator program)
Reception
YES (Print out all report/When error
occurs/No printed report. With key
operator program)
occurs/No printed report. With key
operator program)
Confidential
reception
reception
YES (Print out notice page/Not print
out notice page. With key operator
program)
out notice page. With key operator
program)
Image memory print
YES (Print out all report/When error
occurs/No printed report. With key
operator program)
occurs/No printed report. With key
operator program)
AR-FX7 SPECIFICATIONS 2 - 5
(3) Other report list
13. Others
Rapid # list
YES (Rapid key table)
Group list
YES (Group number table)
Telephone number list
YES (Table of searched
letters in rapid key dialing,
and group dialing in
alphabetical order)
letters in rapid key dialing,
and group dialing in
alphabetical order)
Program list
YES
Relay group list
YES
Transmission message list
NO
Pass code list
YES
Mem. polling list
YES
Confidential reception list
YES
Activity report
YES
Timer list
YES
Confidential code list
YES
FAX key operator program list
YES
FAX account usage list
YES
F code memory box list
YES
Junk FAX number list
YES
Soft switch list (Output by SIM)
YES
Memory image deletion table
NO
Department code table
NO
CSI transmission
YES
Department
management
management
Limitation on users
in each department
in each department
YES
Number of
departments
registered
departments
registered
100 items
Charge
management
function for each
department
management
function for each
department
NO
Automatic booting mode
NO
WIN FAST
YES
Distinctive ring
NO
Summer time setting
YES (Start: the last Sunday in
March 1:00
March 1:00
→
2:00
End: the last Sunday in
October 1:00
October 1:00
→
0:00)
(Default: ON)
Address book import/export
In Japanese and English
PC-FAX
Supplied languages: English,
French, Swedish, Italian,
Spanish, German, Dutch,
Danish, Finish/Norwegian
(TX only to RX. not available)
French, Swedish, Italian,
Spanish, German, Dutch,
Danish, Finish/Norwegian
(TX only to RX. not available)
AR-FX7 INSTALLATION PROCEDURE 3 - 1
[3] INSTALLATION PROCEDURE
1. Install of expansion kit
A. Parts included
B. Installation procedure
Turn off the main switch of the copier and then remove the
power plug of the copier from the outlet.
power plug of the copier from the outlet.
1) Remove the shielding plate and the left rear cabinet.
Remove the five screws that fix the shielding plate and then
remove the shielding plate by inserting a flat-blade screwdriver.
remove the shielding plate by inserting a flat-blade screwdriver.
Then, remove the two screws that secure the left rear cabinet and
slide the cabinet toward the rear side of the main unit to remove it.
slide the cabinet toward the rear side of the main unit to remove it.
2) Work the left rear cabinet.
Cut and remove the cut-out portion from the left rear cabinet using
a tool such as nippers.
a tool such as nippers.
Be careful about the direction of the tool so that the cut surface is
flat.
flat.
3) Attach the speaker.
Attach the speaker to the left rear cabinet using supplied two
golden screws (M3).
golden screws (M3).
4) Attach the fax PWB
Mount the two spacers on the fax PWB.
Then, insert the connector of the FAX PWB to the connector of the
FAX expansion PWB and secure it using six M3 screws with
washer.
FAX expansion PWB and secure it using six M3 screws with
washer.
PWB spacers: 2 pcs.
Fax PWB: 1 pc.
TEL/LIU PWB: 1 pc.
Speaker unit:
1pc.
Fax connector cover:
1 pc.
Line cable: 1 pc.
M3 golden screws:
2 pcs.
M3 screws with
washer: 8 pcs.
Supplied label:
1 sheet (For SUK)
Installation manual:
1 sheet
Operation manuals:
1 pc.
Quick reference
booklet: 1pc.
(For SEN, SEB)
Line adapter: 1 pc.
(For SUK, SEB,
SEES, SEZ)
Shielding plate
Screws
Screws
Left rear cabinet
Cut-out portion
M3 golden screws
M3 Screws with washer
M3 Screws with washer
Fax PWB
Spacers
AR-FX7 INSTALLATION PROCEDURE 3 - 2
5) Attach the TEL/LIU PWB.
Insert the connector of the TEL/LIU PWB to the connector of the
FAX PWB, fit two spacers to the TEL/LIU PWB, and attach the
TEL/LIU PWB using two M3 screws with washer.
FAX PWB, fit two spacers to the TEL/LIU PWB, and attach the
TEL/LIU PWB using two M3 screws with washer.
6) Reattach the left rear cabinet.
<1> Pass the speaker harness through the hole of the frame of the fax
expansion PWB and connect it to the connector of the fax PWB.
<2> Fit the pawls of the left rear cabinet to the mounting portions of
the main unit. Slide the cabinet toward the front of the main unit to
attach it.
attach it.
<3> Secure the left rear cabinet using two screws.
<4> Attach the supplied fax connector cover.
<Step for mounting extended memory (AR-MM9)>
If you need not to mount an extended memory, proceed to step 8.
7) Mount an additional memory (AR-MM9)
Insert the additional memory into the socket on the FAX PWB.
8) Reattach the shielding plate.
Fit the pawls of the shielding plate to the main unit and secure the
plate using five screws.
plate using five screws.
Insert the power plug of the copier to the outlet and turn
on the main switch. Then, carry out the following
procedure.
on the main switch. Then, carry out the following
procedure.
9) Clear the image memory.
* If an extended memory (AR-MM9) has been mounted in step 7, be
sure to carry out this step.
If no extended memory has been mounted, this step is not neces-
sary.
If no extended memory has been mounted, this step is not neces-
sary.
<1> [P], [*], [C], and [*] to enter the simulation mode.
<2> Use the 10-key pad to enter “66” in the main code entry screen
shown below and press the START key.
<3> Use the 10-key pad to enter “10” in the sub-code entry screen
shown below.
<4> Use the 10-key pad to enter “1” in the submenu screen shown
below and press the START key.
<5> The screen shown below is displayed and memory clear opera-
tion is executed to restart the main unit.
TEL/LIU PWB
M3 Screws with washer
Spacers
Speaker harness
Screws
Left rear cabinet
Fax connector cover
Pawls
Screw
Screws
Shielding plate
Click on the first or last page to see other AR-FX7 service manuals if exist.