DOWNLOAD Sharp AR-FX7 Service Manual ↓ Size: 4.14 MB | Pages: 104 in PDF or view online for FREE

Model
AR-FX7
Pages
104
Size
4.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARFX7-Service Manual
File
ar-fx7.pdf
Date

Sharp AR-FX7 Service Manual ▷ View online

AR-FX7  SPECIFICATIONS  2 - 1
[2] SPECIFICATIONS
1.
Communication system
(1) Electronic transmission system
2.
Scanning system
(1) Document size
(2) Transmission mode document load quantity scan 
cycle (RSPF capacity)
3.
Image process system
(1) Half-tone reproduction density adjustment
(2) Image selection
(3) Print resolution
4.
Print system
(1) Recording size
(2) Recording paper
5.
Transmission function system
(1) Simplified dialing function
(2) F-code communication
(3) Time specification
(4) Recall mode
(5) Automatic reduction transmission
Transmission time
Less than 3 sec (Super G3/33600bps)
Approx. 6 sec (G3 ECM/14400bps)
Compression system
MH, MR, MMR, JBIG
Modem speed
33600bps 
 2400bps auto fall back
Mutual 
communication
Super G3/G3
Employed line
Public Switched Telephone Network 
(PSTN), Private Branch Exchange (PBX)
R-key operation when 
setting PBX
YES (Germany only)
Number of employed 
lines
One line
ECM
YES
Max. document 
width
297mm (11.7")
Unscanable area
Lead edge 5mm or less, rear edge 5mm or less
left & right edges 6mm or less
Auto 
detection 
size
OC
AB series
A3/B4/A4/A4R/A5
Inch series
11 x 17/8.5 x 14/8.5 x 11/8.5 x 
11R/5.5 x 8.5
RSPF
AB series
A3/B4/A4/A4R/A5/A5R
Inch series
11 x 17/8.5 x 14/8.5 x 11/
8.5 x 11R/5.5 x 8.5/5.5 x 8.5R
Document size 
specified
AB series
A3/B4/A4/A4R/B5/B5R/A5/A5R
Inch series
8.5 x 11/8.5 x 11R
Duplex document 
specified
YES
Long document
Max. 1000mm
(A3 width 297mm/except when ultra fine)
RSPF/OC 
transmission select
NO (Selection inhibited during scanning of a 
document)
Continuous auto 
paper feed
YES
Document load 
capacity
RSPF: 100 sheets
Document scan cycle
40 pages/min (Normal, A4R memory 
transmission)
Document scan 
speed
About 1.5sec/page (Normal, A4R memory 
transmission)
Job build (Large 
document mode)
YES
Slow scan mode
YES
Half-tone
Equivalent to 256 gradations (Combination 
of fine/super fine/ultra fine is possible.)
Exposure selection
Auto/manual in 5 steps
Standard
8dot/mm x 3.85line/mm
Fine
8dot/mm x 7.7line/mm
Super fine
8dot/mm x 15.4line/mm
Ultra fine
16dot/mm x 15.4line/mm: ITU-T conforming
600dpi (with resolution correction)
Max. record width
293mm (11.5")
Recording paper size 
detection
YES (All sizes except paper from multi 
bypass tray.
 →
 Recognition of the set size. 
The tray has no function to detect the actual 
paper size.)
Recording paper size
AB series
A3/B4/A4/A4R/B5/B5R/A5/
8.5 x 11/8.5 x 11R
Inch series
11 x 17/8.5 x 14/8.5 x 11/
8.5 x 11R/5.5 x 8.5/A4/A4R
Recording paper 
empty detection
YES
Paper feed
All installed trays except for multi-bypass 
tray.
Reception paper full 
detection
YES
Rapid key dialing/
Group dialing 
registration per
500 numbers (Total volume of rapid key and 
group dialing)
Chain dialing
YES
Redialing
The preceding number in single address 
transmission is registered. (except time 
specification)
Not cleared even by clear all key
Mode recall
NO
Sub address
YES (Max. 20 digits)
Password
YES (Max. 20 digits)
Time specification: 
Transmission/polling
Time is specified in transmission/polling.
Call time in memory 
send
30sec / 45sec / 60 sec
Default: 45 sec
Auto recall mode 
when other party 
is busy.
Interval
1min to 15min, default 3min
Number of 
times
1 to 10 times / No resend
Default 2 times
Recall mode 
when in a 
communication 
error
Interval
1min to 15min / 0: Resend 
immediately after disconnection of 
the line
Default: 1 min
Number of 
times
1 to 5 times / No resend
Default: Once
Send page
Page with which the error occurred
Number of transmissions 
counted in recall mode 
simultaneously.
Max. 50 items
Subsequent transmission 
reservation override in recall 
mode
NO
YES (ON/OFF by key operator program)
AR-FX7  SPECIFICATIONS  2 - 2
(6) Memory transmission/direct transmission
(7) Broadcast function
(8) Scan specification
(9) Priority function
(10) Multiple message transmission
(11) Rotation transmission
(12) Book document transmission
(13) Finish stamp
(14) Bulletin board (remote transmission, polling 
transmission functions)
6.
Reception function system
(1) Reception mode
(2) Zoom reception
(3) Memory reception function
(4) Received data skip output
(5) Transfer
(6) Specified number reception
Memory transmission
YES
Number of reservation 
to be set
Max. 50 items
Process in memory full
Transmission cancel or only 
scanned data transmission
Quick online transmission
YES (Enable/Disable setup by key 
operator program)
Direct transmission
YES (100 pages from RSPF, only 1 
page from OC)
Default setup
Set by key operator program
Broadcast 
transmission
Number of 
destinations
200 destinations (When group 
dialing is used, the number of 
other parties registered to group 
dialing is added.)
Transmission 
method
10-key, rapid key dialing, group 
key, next address key
Usable dial
10-key entry, rapid key dialing, 
group key dialing.
However, an address including 
sub address of 10-key entry 
registered cannot be used. 
Group dialing
Transmitted by group dialing 
registered to rapid key dialing
Relay 
broadcast 
transmission
Instructing 
station
Only from the machine having 
Sharp relay broadcast 
instructing transmission function
Relay station
Only from the machine having 
Sharp relay broadcast 
transmission function
Multi-stage relay
NO
Number of relay 
groups
10 groups
F code relay broadcast 
instruction (relay broadcast 
instruction function)
YES
F code relay broadcast (relay 
function)
YES
Confidential transmission (Sharp 
machine mode) (Other party)
Only Sharp machine having 
confidential function
Confidential transmission (F code 
communication) (Other party)
F code support machine
Page division
YES (Allowed only from OC)
Applicable size: A3/B4/A4R
Page linkage
NO
Transmission reservation interrupt
YES (check by job status key)
Broadcast interrupt
YES (by direct transmission)
Multiple message transmission
NO
Paper size
A4 
 A4R, A5R 
 A5, 
8.5 x 11 
→ 
8.5 x 11R
Transmission method
By OC mode
NO
Bulletin board 
(remote 
transmission)
YES
Polling protection 
function
Check by other party’s number
YES
Check by matching of system number 
(user’s own machine), ID number 
(other party’s machine) (between 
Sharp machines only)
YES
F code bulletin 
board
YES
F code bulletin 
board box
Registered up to 10 boxes
F code bulletin 
board box name
Registered up to 36 letters (18 letters are 
displayed)
Default setup
Automatic reception (Reception 
state switchable)
Automatic 
reception
Automatic 
reception setup
YES
Number of calls
0 to 9 times (Factory default 2 
times)
Non-call reception
Allowed by setting the number of 
calls to 0.
Manual reception setup
YES
Setup for switching to automatic 
reception
0 to 9 times (Factory setup 0 
time) (France only)
Auto reduction setup in letter 
reception
NO
Auto reduction setup in A3 
reception (A3 RX REDUCE)
NO
Answering machine connection
NO
Reception mode time switch
NO
Reception data print condition 
setup
Set whether the received data 
are reduced or divided to print, 
by the key operator program.
Auto reduction print on the 
paper size
YES (ON/OFF by key operator 
program)
Memory delayed receiving
Only when output is disabled.
Forced memory receiving
NO
YES
Transfer destination 
registration
YES (Registered by key operator 
program)
Transfer procedure
YES (Operated by function menu)
Only designated number 
receiving enabled.
NO
Reception reject setup 
(ANTI JUNK FAX)
YES (ON/OFF by key operator 
program)
Registration of the 
numbers to be rejected
50 items (up to 20 digits each) 
Registered by key operation program.
AR-FX7  SPECIFICATIONS  2 - 3
(7) Confidential function
(8) Rotation reception
(9) Division reception
(10) Duplex reception
(11) 2 in 1 reception
(12) Polling
(13) Turn around transmission
7.
Registration system
(1) Number registration
(2) Sender registration
(3) Polling (Registration of allow number)
(4) Letter input
(5) Registered data read/write
(6) Date/time adjustment
(7) Backup
8.
Telephone function system
Confidential reception (Sharp 
machine mode) (Sender)
Sharp machine having confidential 
function only
Confidential box
Registered up to 10 boxes
Confidential box name
Registered up to 36 letters (18 
letters displayed)
Confidential ID code
Set per confidential box
Confidential (F code 
communication) (Sender)
F code support machine
F code confidential box
Registered up to 10 boxes
F code confidential box name
Registered up to 36 letters (18 
letters displayed)
F code confidential box print 
pass code
YES (4 digits)
Paper is outputted by rotating 90 degrees to the set direction of 
paper in cassette
Division size
When a long original is received, machine 
outputs the data according to the condition set 
through key operator program.
YES
NO
Send request
YES
Resolution
Ultra Fine (Change by the soft SW)
NO
Rapid 
dialing
Number of items 
(Include group)
500 items
Number of digits 
of other party’s 
number
50 digits (+ Sub address 20 digits, 
pass code 20 digits)
User tag 
classification
YES
International 
communication 
mode setup
YES
Transmission 
method
Rapid dialing key + Start key
Group 
dialing
Registered key
Rapid dialing key
10-key (Sub address not available)
Max. number of 
registration per 
group dialing
200 items (The total number of 
registration is 200 items.)
Registerable 
number
Numbers registered to rapid dialing, 
and numbers entered with 10-key
Registered name
36 letters
User tag 
classification
YES
Transmission 
method
Rapid dialing key + Start key
Program
Number of items
8 items
Registerable 
items
All items during transmission except 
time specification/original/document 
size/duplex/job build.
Registered name
36 letters
Call method
By pressing program key
Change in setup 
after calling
NO (Change in setup is available for 
time specification/document size/
original/duplex/job build. (Cannot set 
duplex/job build if select dual page 
scan when setting.))
Relay 
group
Number of items
10 groups
Registered name
36 letters
Relay station 
number 
registration
10-key only
Reception 
station number 
registration
10-key dialing
(Input the number that registered in 
relay station for rapid/group/speed 
dial)
Sender’s name
20 items (registration/display: 22 letters)
Registered by key operator program.
Sender’s number
20 digits, registered with key operator program
Registration of 
polling allow 
number
10 items, 20 digits, registered by key operator 
program
System number 
registration
1 items, 4 digits, registered by key operator 
program
Registration of 
polling allow ID 
number
Up to 10 items in 4 digits. Registered by key 
operator program.
Relay ID code 
registration
10 items, 20 digits, registered by key operator 
program
Key entry
YES
Letters allowed 
for input
3 types of keyboard available
YES (Service tool. Dial registration can be made with PC.)
Registered by key operator program.
Backup of registration in power 
failure
SRAM used, by built-in battery
Handset
NO
On-hook function
YES
Reserve
NO
Pause
YES (1 to 15sec: Default 2sec, set 
by key operator program)
Telephone transmission in 
power failure
NO (However, external telephone 
transmission is allowed.)
Sound 
volume 
adjustment
Ringer volume
YES (Set by key operator program 
to High/Medium/Low/Silent.)
Line monitor 
sound
YES (Set by key operator program 
to High/Medium/Low/Silent.)
Speaker sound
YES (Set by key operator program 
to High/Medium/Low.)
Transmission 
complete sound
YES (Set by key operator program 
to High/Medium/Low/Silent.)
AR-FX7  SPECIFICATIONS  2 - 4
9.
Memory system
10. Additional information function for 
transmission
11. Additional print function when 
receiving
12. Recording table system
(1) Communication record function
(2) Communication result report function
Transmission complete sound 
tone setup (transmission end)
YES (Set by key operator program 
to PATTERN 1/2/3.)
Transmission complete sound 
tone setup (reception end)
YES (Set by key operator program 
to PATTERN 1/2/3.)
Transmission complete sound 
time setup
YES (Set by key operator program. 
2.0/2.5/3.0/3.5/4.0 sec.)
Scan end sound
YES (Set by soft switch.)
Tone pulse switch
Cancel tone/pulse switch set by the 
key operator program.
Set with the service switch.
External telephone 
connection
YES
Remote 
reception switch
YES (Switch number is in 1 digit + 
∗∗
) 5
∗∗
Telephone/
Fax
Sound 
response
NO
Answering 
voice recording
NO
Memory capacity
Standard
2MB
Option
8MB
Memory content 
(transmission 
reservation) 
confirmation
LCD display
YES
Printout
YES
Memory use status
YES (% display)
Document data memory backup 
in power failure
YES (Flash memory)
Page counter
YES
Date printing
YES (day/month/year/the day of 
week, year is in 4 digits)
Date/ display sequential 
switch
NO
Cover 
paper item
Date
YES
Receiver’s 
name
YES
Receiver’s 
number
YES
Sender’s 
name
YES
Sender’s 
number
YES
Display of 
number of 
documents 
transmitted
YES
Transmission 
message
YES
Print paper 
size
A4
Transmission message 
(Regular message)
(U.K.)
CONFIDENTIAL/PLEASE.
DISTRIBUTE/URGENT/PLEASE
CALL BACK/IMPORTANT
(France)
COFIDENTIEL/
VEUILLEZ DISTRIBUER
URGENT
VEUILLEZ RAPPELER
IMPORTANT
(Germany)
VERTRAULICH
BITTE VERTEILEN
EILIG
BITTE RÜCKRUF
WICHTIG
Sender print
NO
User message
NO
Index print
YES (Set by key operator program)
Communication record 
table size
A4 (Not output when paper larger than 
A5 is not set.)
Communication record 
memory capacity
50 items in total of transmission and 
reception
Communication record 
table
Max. 50 items for each of transmission 
and reception (Total of transmission and 
reception is up to 50 items.) Record table 
is outputted separately. If registration 
exceeds 50, the oldest one is deleted.
Time-specified output
YES (1 time per day)
Output when 
recording memory full
YES (Print/not print is set by key 
operator)
Output of individual 
department
YES (Communication time of each 
department is outputted as department 
management record table.)
Time-specified 
communication table
Common with transmission record table
Confidential reception 
check table
YES
Commu-
nication 
result 
table
Single sending
YES (Print out all report/Print out 
error report only/No printed report. 
With key operator program)
Broadcast 
communication 
report
YES (Print out all report/Print out 
error report only/No printed report. 
With key operator program)
Reception
YES (Print out all report/When error 
occurs/No printed report. With key 
operator program)
Confidential 
reception
YES (Print out notice page/Not print 
out notice page. With key operator 
program)
Image memory print
YES (Print out all report/When error 
occurs/No printed report. With key 
operator program)
Page of 104
Display

Sharp AR-FX7 Service Manual ▷ Download

  • DOWNLOAD Sharp AR-FX7 Service Manual ↓ Size: 4.14 MB | Pages: 104 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AR-FX7 in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-FX7 Copying Equipment. Information contained in Sharp AR-FX7 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.