CONTENTS
[1] OUTLINE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
[2] SPECIFICATIONS
1. Communication system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2. Scanning system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
3. Image process system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
4. Print system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
5. Transmission function system . . . . . . . . . . . . . . . . . . . . . . . 2-1
6. Reception function system. . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
7. Registration system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
8. Telephone function system . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
9. Memory system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
10. Additional information function for transmission  . . . . . . . . . 2-4
11. Additional print function when receiving  . . . . . . . . . . . . . . . 2-4
12. Recording table system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
13. Others  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
[3] INSTALLATION PROCEDURE
1. Install of expansion kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
A. Parts included. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
B. Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
[4] OPERATION, DISPLAY SECTION
1. Operation panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
2. FAX mode (Condition setting screen) . . . . . . . . . . . . . . . . . 4-1
A. Condition setting screen. . . . . . . . . . . . . . . . . . . . . . . . . 4-1
B. Address directory screen (alphabetically ordered) . . . . . 4-2
[5] ADJUSTMENTS
1. Density section  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
A. FAX mode density adjustment (Overall mode) 
(<FAX mode> SIM 46-12)  . . . . . . . . . . . . . . . . . . . . . . . 5-1
B. FAX mode density adjustment (Individual mode) 
(<FAX mode> SIM 46-13 – 16)  . . . . . . . . . . . . . . . . . . . 5-1
2. Communication section . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
A. Dial test (<FAX mode> SIM 66-14, 16)  . . . . . . . . . . . . . 5-2
[6] SIMULATION
1. Code-type simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
A. Operating procedures and operations . . . . . . . . . . . . . . 6-1
2. Simulation code list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
3. Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
[7] SOFT SWITCH
1. FAX soft switch setting change quick reference table  . . . .  7-1
2. Soft SW list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7-2
3. Soft switch descriptions  . . . . . . . . . . . . . . . . . . . . . . . . . .  7-27
[8] MACHINE OPERATION
1. Key operator program . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-1
A. List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-1
B. Operating procedure . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-2
2. Power switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-3
3. Originals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-3
A. Original sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-3
B. Scanning area of original. . . . . . . . . . . . . . . . . . . . . . . .  8-3
C. Automatic reduction of faxed document  . . . . . . . . . . . .  8-4
4. Own number sending . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-4
A. Position of sender's information  . . . . . . . . . . . . . . . . . .  8-4
5. Quick On-line  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-4
[9] FLASH ROM VERSION UP PROCEDURE
1. Program download method 
(for Copier,  and fax program)  . . . . . . . . . . . . . . . . . . . . . .  9-1
2. Others (Troubleshooting)  . . . . . . . . . . . . . . . . . . . . . . . . . .  9-2
[10] TROUBLE CODE LIST
1. Machine trouble codes . . . . . . . . . . . . . . . . . . . . . . . . . . .  10-1
2. Communication result code  . . . . . . . . . . . . . . . . . . . . . . .  10-2
A. Composition of communication report code  . . . . . . . .  10-2
3. List of buzzer sounds in case of FAX abnormality  . . . . . .  10-3
[11] ELECTRICAL SECTION
1. Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11-1
A. Main block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . .  11-1
B. TEL/LIU PWB block diagram. . . . . . . . . . . . . . . . . . . .  11-1
2. Circuit diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11-2
A. FAX MAIN PWB  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11-2
B. TEL LIU PWB  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11-22
AR-FX7  OUTLINE  1 - 1
[1] OUTLINE
This unit is a fax expansion kit which provides facsimile functions by
attaching to the digital machine AR-M236/M276 series.
To expand facsimile functions, use of RSPF is recommendable. By
attaching a job separator/finisher, copy output and fax output can be
separately discharged to different trays.
The fax board of the fax expansion kit is provided with 2MB flash mem-
ory (standard). An expansion memory of one of 8MB can be added.
(8MB expansion memory for fax, AR-MM9)
Job separator
(AR-TR3)
Finisher
(AR-FN5N)
AR-MM9
Expansion memory
8MB
RSPF (AR-RP7)
AR-M236/M276
Facsimile expansion Kit
(AR-FX7)
AR-FX7  SPECIFICATIONS  2 - 1
[2] SPECIFICATIONS
1.
Communication system
(1) Electronic transmission system
2.
Scanning system
(1) Document size
(2) Transmission mode document load quantity scan 
cycle (RSPF capacity)
3.
Image process system
(1) Half-tone reproduction density adjustment
(2) Image selection
(3) Print resolution
4.
Print system
(1) Recording size
(2) Recording paper
5.
Transmission function system
(1) Simplified dialing function
(2) F-code communication
(3) Time specification
(4) Recall mode
(5) Automatic reduction transmission
Transmission time
Less than 3 sec (Super G3/33600bps)
Approx. 6 sec (G3 ECM/14400bps)
Compression system
MH, MR, MMR, JBIG
Modem speed
33600bps 
 2400bps auto fall back
Mutual 
communication
Super G3/G3
Employed line
Public Switched Telephone Network 
(PSTN), Private Branch Exchange (PBX)
R-key operation when 
setting PBX
YES (Germany only)
Number of employed 
lines
One line
ECM
YES
Max. document 
width
297mm (11.7")
Unscanable area
Lead edge 5mm or less, rear edge 5mm or less
left & right edges 6mm or less
Auto 
detection 
size
OC
AB series
A3/B4/A4/A4R/A5
Inch series
11 x 17/8.5 x 14/8.5 x 11/8.5 x 
11R/5.5 x 8.5
RSPF
AB series
A3/B4/A4/A4R/A5/A5R
Inch series
11 x 17/8.5 x 14/8.5 x 11/
8.5 x 11R/5.5 x 8.5/5.5 x 8.5R
Document size 
specified
AB series
A3/B4/A4/A4R/B5/B5R/A5/A5R
Inch series
8.5 x 11/8.5 x 11R
Duplex document 
specified
YES
Long document
Max. 1000mm
(A3 width 297mm/except when ultra fine)
RSPF/OC 
transmission select
NO (Selection inhibited during scanning of a 
document)
Continuous auto 
paper feed
YES
Document load 
capacity
RSPF: 100 sheets
Document scan cycle
40 pages/min (Normal, A4R memory 
transmission)
Document scan 
speed
About 1.5sec/page (Normal, A4R memory 
transmission)
Job build (Large 
document mode)
YES
Slow scan mode
YES
Half-tone
Equivalent to 256 gradations (Combination 
of fine/super fine/ultra fine is possible.)
Exposure selection
Auto/manual in 5 steps
Standard
8dot/mm x 3.85line/mm
Fine
8dot/mm x 7.7line/mm
Super fine
8dot/mm x 15.4line/mm
Ultra fine
16dot/mm x 15.4line/mm: ITU-T conforming
600dpi (with resolution correction)
Max. record width
293mm (11.5")
Recording paper size 
detection
YES (All sizes except paper from multi 
bypass tray.
 →
 Recognition of the set size. 
The tray has no function to detect the actual 
paper size.)
Recording paper size
AB series
A3/B4/A4/A4R/B5/B5R/A5/
8.5 x 11/8.5 x 11R
Inch series
11 x 17/8.5 x 14/8.5 x 11/
8.5 x 11R/5.5 x 8.5/A4/A4R
Recording paper 
empty detection
YES
Paper feed
All installed trays except for multi-bypass 
tray.
Reception paper full 
detection
YES
Rapid key dialing/
Group dialing 
registration per
500 numbers (Total volume of rapid key and 
group dialing)
Chain dialing
YES
Redialing
The preceding number in single address 
transmission is registered. (except time 
specification)
Not cleared even by clear all key
Mode recall
NO
Sub address
YES (Max. 20 digits)
Password
YES (Max. 20 digits)
Time specification: 
Transmission/polling
Time is specified in transmission/polling.
Call time in memory 
send
30sec / 45sec / 60 sec
Default: 45 sec
Auto recall mode 
when other party 
is busy.
Interval
1min to 15min, default 3min
Number of 
times
1 to 10 times / No resend
Default 2 times
Recall mode 
when in a 
communication 
error
Interval
1min to 15min / 0: Resend 
immediately after disconnection of 
the line
Default: 1 min
Number of 
times
1 to 5 times / No resend
Default: Once
Send page
Page with which the error occurred
Number of transmissions 
counted in recall mode 
simultaneously.
Max. 50 items
Subsequent transmission 
reservation override in recall 
mode
NO
YES (ON/OFF by key operator program)
AR-FX7  SPECIFICATIONS  2 - 2
(6) Memory transmission/direct transmission
(7) Broadcast function
(8) Scan specification
(9) Priority function
(10) Multiple message transmission
(11) Rotation transmission
(12) Book document transmission
(13) Finish stamp
(14) Bulletin board (remote transmission, polling 
transmission functions)
6.
Reception function system
(1) Reception mode
(2) Zoom reception
(3) Memory reception function
(4) Received data skip output
(5) Transfer
(6) Specified number reception
Memory transmission
YES
Number of reservation 
to be set
Max. 50 items
Process in memory full
Transmission cancel or only 
scanned data transmission
Quick online transmission
YES (Enable/Disable setup by key 
operator program)
Direct transmission
YES (100 pages from RSPF, only 1 
page from OC)
Default setup
Set by key operator program
Broadcast 
transmission
Number of 
destinations
200 destinations (When group 
dialing is used, the number of 
other parties registered to group 
dialing is added.)
Transmission 
method
10-key, rapid key dialing, group 
key, next address key
Usable dial
10-key entry, rapid key dialing, 
group key dialing.
However, an address including 
sub address of 10-key entry 
registered cannot be used. 
Group dialing
Transmitted by group dialing 
registered to rapid key dialing
Relay 
broadcast 
transmission
Instructing 
station
Only from the machine having 
Sharp relay broadcast 
instructing transmission function
Relay station
Only from the machine having 
Sharp relay broadcast 
transmission function
Multi-stage relay
NO
Number of relay 
groups
10 groups
F code relay broadcast 
instruction (relay broadcast 
instruction function)
YES
F code relay broadcast (relay 
function)
YES
Confidential transmission (Sharp 
machine mode) (Other party)
Only Sharp machine having 
confidential function
Confidential transmission (F code 
communication) (Other party)
F code support machine
Page division
YES (Allowed only from OC)
Applicable size: A3/B4/A4R
Page linkage
NO
Transmission reservation interrupt
YES (check by job status key)
Broadcast interrupt
YES (by direct transmission)
Multiple message transmission
NO
Paper size
A4 
 A4R, A5R 
 A5, 
8.5 x 11 
→ 
8.5 x 11R
Transmission method
By OC mode
NO
Bulletin board 
(remote 
transmission)
YES
Polling protection 
function
Check by other party’s number
YES
Check by matching of system number 
(user’s own machine), ID number 
(other party’s machine) (between 
Sharp machines only)
YES
F code bulletin 
board
YES
F code bulletin 
board box
Registered up to 10 boxes
F code bulletin 
board box name
Registered up to 36 letters (18 letters are 
displayed)
Default setup
Automatic reception (Reception 
state switchable)
Automatic 
reception
Automatic 
reception setup
YES
Number of calls
0 to 9 times (Factory default 2 
times)
Non-call reception
Allowed by setting the number of 
calls to 0.
Manual reception setup
YES
Setup for switching to automatic 
reception
0 to 9 times (Factory setup 0 
time) (France only)
Auto reduction setup in letter 
reception
NO
Auto reduction setup in A3 
reception (A3 RX REDUCE)
NO
Answering machine connection
NO
Reception mode time switch
NO
Reception data print condition 
setup
Set whether the received data 
are reduced or divided to print, 
by the key operator program.
Auto reduction print on the 
paper size
YES (ON/OFF by key operator 
program)
Memory delayed receiving
Only when output is disabled.
Forced memory receiving
NO
YES
Transfer destination 
registration
YES (Registered by key operator 
program)
Transfer procedure
YES (Operated by function menu)
Only designated number 
receiving enabled.
NO
Reception reject setup 
(ANTI JUNK FAX)
YES (ON/OFF by key operator 
program)
Registration of the 
numbers to be rejected
50 items (up to 20 digits each) 
Registered by key operation program.
Page of 104
Display

Sharp AR-FX7 Service Manual ▷ Download

  • DOWNLOAD Sharp AR-FX7 Service Manual ↓ Size: 4.14 MB | Pages: 104 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AR-FX7 in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-FX7 Copying Equipment. Information contained in Sharp AR-FX7 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.