Sharp AR-FN7 (serv.man13) Service Manual / Technical Bulletin ▷ View online
ARE351
Sharp Electronics (UK) Ltd., Technical Services Group
1.Model Name:
AR-FN7
2.General:
We would like to inform you of the adjustment procedure for inclination of the discharge
tray related to the machine with the above model name.
tray related to the machine with the above model name.
3.Description:
1) Remove the front cover and the rear cover.
2) Remove the belt holder (mould) on the front side.
2) Remove the belt holder (mould) on the front side.
3) Rotate the pulley on the rear side and lower the rollers of the tray to the bend in the
metal plate. (For both the rear side and front side)
4) Check that the rollers on the front and rear sides of the tray touch the bend in the metal
plate so that they are correctly positioned. Then, reattach the belt holder that was
removed in step 2) above. Before attaching the belt holder, make sure to remove the
plate spring.
removed in step 2) above. Before attaching the belt holder, make sure to remove the
plate spring.
ADJUSTMENT PROCEDURE FOR INCLINATION OF
THE AR-FN7 TRAY
TECHNICAL BULLETIN
Date:
13 March 2002
Model: ARFN7
Ref.:
Ref.:
005
Colour: White
Page:
Page:
1 of 2
ARE351
Sharp Electronics (UK) Ltd., Technical Services Group
5) Rotate the pulley on the rear side and raise the tray by about 10 cm. Then, attach the
plate spring while holding the belt.
(Be careful not to damage the plate spring.)
Note: If the tray is not positioned correctly, errors such as F1-15 may occur.
Display