CHAPTER 1   GENERAL DESCRIPTION
1-23
3)
Turn the knob on the left side.
Figure 1-325
4)
Turn the knob on the right side while pushing
it in.
Figure 1-326
5)
Remove the jam.
Figure 1-327
6)
Open the inlet cover, and remove the jam.
Figure 1-328
7)
Close the front lower cover.
Figure 1-329
8)
 Connect the finisher unit.
9)
Operate as instructed on the display.
CHAPTER 1   GENERAL DESCRIPTION
1-24
E.
Supplying the Saddle 
Stitch Unit with Staples 
(Saddle Finisher)
If the host machine indicates the saddle stitch
unit staple supply message, perform the following
to supply it with staples.
1)
Open the front lower cover.
Figure 1-330
2)
Slide out the stitch unit.
Figure 1-331
3)
Pull the stitch unit to the front once, and then
shift it up.
Figure 1-332
4)
Hold the empty cartridge on its sides, and
remove it.
Figure 1-333
5)
Set a new cartridge.
Figure 1-334
Reference
You must always replace both cartridges at the
same time.
CHAPTER 1   GENERAL DESCRIPTION
1-25
6)
Pull the stitch to the front once, and then
return it to its original position.
Figure 1-335
7)
Push in the stitch unit, and close the front
cover.
Figure 1-336
F.
Removing Staple Jams 
from the Saddle Stitch 
Unit (Saddle Finisher)
If the host machine indicates the saddle stitch
unit staple jam message, perform the following to
remove the jam.
1)
Open the front lower cover.
Figure 1-337
2)
Slide out the stitch unit.
Figure 1-338
3)
Pull the stapler of the stitch unit to the front
once, and then shift it up.
Figure 1-339
CHAPTER 1   GENERAL DESCRIPTION
1-26
4)
Hold the cartridge on its sides, and remove it.
Figure 1-340
5)
Push down on the area identified as A, and
pull up the tab identified as B.
Figure 1-341
6)
Remove the staple jam, and return the tab B
to its original position.
Figure 1-342
7)
Return the cartridge to its original position.
Figure 1-343
8)
Pull the stitch of the stitch unit to the front
once, and then return it to its original posi-
tion.
Figure 1-344
9)
Push the stitch unit back to its original posi-
tion, and close the front lower cover.
Figure 1-345
Reference
Whenever you have removed a staple jam, be sure
to execute staple edging.
Page of 127
Display

Click on the first or last page to see other AR-F12 (serv.man6) service manuals if exist.