Copying Equipment / (Section 5) External View Internal Structure
File
ar-c270-sm6.pdf
Date

Sharp AR-C270 (serv.man6) Service Manual ▷ View online

No.
Parts
Model
Note
Code
Signal
name
Name
Type
Function/Operation
Active
condition
10
CALS
CALS
Sensor switch
solenoid
Selects the image density
sensor.
Switches the
sensor angle
depending on
detection of
color toner
patch density or
black toner
patch density.
11
TC high voltage
power PWB
Generates the high voltage
for transfer.
12
Transfer belt
Transfers toner images on
the OPC drum onto paper.
13
Waste toner tank
Collects toner of toner patch
used in image density
correction.
14
Transfer belt
cleaning blade
Cleans toner of toner patch
used in image density
correction.
15
Transfer belt idle
roller
Applies a tension to the
transfer belt.
16
Transfer belt
cleaning pad
Cleans the back of the
transfer belt.
17
BLUD
BLUD
Transfer belt
position sensor
Photo sensor
(Photo
transmission)
Detects that the transfer belt
is lifted up or down.
L when lifting
up H when
lifting down
18
BTM
BTM
Transfer belt
drive motor
Stepping motor
Drives the transfer belt.
19
PSM
PSM
Resist roller
drive motor
Stepping motor
Drives the resist roller and
controls ON/OFF.
20
HUD
HUD
Temperature
sensor
Detects humidity in the
machine.
Analog input
Each correction
of image
process section
is made
according to
this sensor data.
21
PCU sub PWB
Controls the image process
section.
22
Oil pump
Supplies fusing oil to the
fusing roller.
23
PPD1
PPD1
Paper detector in
front of resist
roller
Photo sensor
(Photo
transmission)
Detects paper in front of the
resist roller.
L with paper
presence
This detector
signal serves as
the paper
transport timing
control signal to
the transfer
section.
24
Upper resist roller
Transports paper to the
transfer section.
25
Lower resist roller
Transports paper to the
transfer section.
The operation
timing is
controlled by
the resist roller
motor.
26
BELTCH1 BELTCH1 Transfer belt
installation
detection switch
(+24V)
Micro switch
Turns ON/OFF the +24V
power line from the DC main
power PWB to the PCU PWB.
ON when the
transfer unit
operation is
allowed.
27
BELTCH2 BELTCH2 Transfer belt
installation
detection switch
(+5V)
Micro switch
Turns ON/OFF the +5V
power line from the DC main
power PWB to the PCU PWB.
ON when the
transfer unit
operation is
allowed.
28
Resist roller
cleaner
Cleaning the resist roller
AR-C160/
C270
5 –  7A
(8) PWB
(AR-C150/C250)
(AR-C160/C270)
1
2
3
16
17
18
19
22
10
11
13
14
7
6
9
15
4
5
17
19
23
25
8
12
31
26
27
24
29
30
28
28
30
29
20
1
2
3
17
18
19
22
10
11
13
14
7
6
20
9
15
16
4
5
17
19
23
25
8
12
31
26
27
24
29
30
28
28
30
29
5 –  8A
No.
Parts
Note
Name
Function/Operation
1
Operation PWB L
Outputs the key operation signals.
2
OP control PWB
Controls the whole operation unit. (Displays information from the PCU PWB, and
sends operation information to the PCU PWB.)
3
Operation PWB R
Outputs the key operation signals.
4
LCD back light inverter PWB
Drives the LCD back light.
5
ICU-Main PWB
Controls the ICU SCN PWB, ICU IMG PWB, and CCD PWB. Converts digital
image data into video signals and sends them to the scanner (writing) unit.
6
ICU-SCN PWB
Performs correction of images outputted from the CCD.
7
ICU-IMG PWB
Performs image processes such as area separation, color correction, black
generation, gamma correction, and filter process.
8
CPT PWB
Recognizes the bank note patterns.
9
Original size sensor PWB
(Light reception)
Detects the original size.
10
Original size sensor (Light
emitting)
Outputs light to detect the original size.
11
CCD power PWB
Outputs the CCD PWB paper power.
12
Scanner motor PWB
Scanner motor control PWB.
Controls the
scanner motor.
13
PCU sub PWB
Controls the image process section.
14
High voltage power PWB
(MC/DV)
Generates the high voltage for main charger and the developing bias voltage.
15
Main charger interface PWB
Interfaces the main charger power.
16
OPC drum motor control/Signal
interface PWB
Controls (drives) the OPC drum motor. (AR-C150/C250/C160/C270)
Signals are interfaced. (AR-C160/C270)
17
Scanner lamp control PWB
Controls the scanner lamp
18
Humidity sensor PWB
Detects humidity in the machine.
Each correction of
image process
section is made by
this sensor data.
19
PCU MAIN PWB
Controls the engine section.
20
CCD ICU interface PWB
Relays the signal of CCD PWB and ICU-SCN PWB. (AR-C150/C250)
Generates the clock at the time of monochrome print operation and relays the
signal of CCD PWB and ICU-SCN PWB. (AR-C160/C270)
21
Paper tray lift unit control PWB
Controls the paper tray lift unit.
Provided in each
paper tray lift unit.
22
Discharge lamp PWB unit
Discharges electric charges on the OPC drum.
23
IFD PWB
Equipped with No. 1/2 paper tray paper exit detectors and the right upper door
open/close detector.
24
PFD PWB unit
Equipped with No. 3/4 paper tray paper exit detectors and the right lower door
open/close detector.
25
Process control PWB
Interfaces signals between the developing unit, OPC drum unit, the high voltage
PWB, and the PCU PWB.
26
Fusing control PWB (AC sub
PWB)
Interfaces the heater lamp drive control, sensor, detector signals.
27
High voltage power PWB (TC)
Generates the transfer voltage.
28
DC main power PWB
(AR-C100/C150/C250)
DC power PWB
(AR-C160/C270)
Generates the voltage used by the other units than the operation unit.
29
DC sub power PWB
(AR-C150/C250)
Power control PWB
(AR-C160/C270)
Generates the voltage for the operation unit (AR-C150/C250)
Controls powers of 24V, 5V and 3.3V in the sleep mode, the preheat mode, and
the normal mode. (AR-C160/C270)
30
AC power PWB
Controls the primary side power (AC power).
31
CCD PWB
Converts original images (light) into electrical signals.
5 –  9A
(9) Fuses, thermostat
(AR-C150/C250)
No.
Parts
Note
Code
Name
Type
Spec
Function/Operation
1
F1
Scanner motor
power fuse
Normal fuse
Protects the scanner motor and its control
circuit from an overcurrent.
Scanner motor
control PWB
2
HLTSU
Upper heat roller
thermostat
Thermostat
Cuts conduction to the heater lamp when the
temperature rises abnormally.
Fusing unit
3
HLTSD
Lower heat roller
thermostat
Thermostat
Cuts conduction to the heater lamp when the
temperature rises abnormally.
Fusing unit
4
F101
OPC drum motor
power fuse
Normal fuse
Protects the OPC drum motor and its control
circuit from an overcurrent.
OPC drum motor
control PWB
5
F701
Scanner lamp
power fuse
Normal fuse
250V 4A
Protects the scanner lamp from an overcurrent.
Scanner lamp
control PWB
6
F712
DC sub power
26V power fuse
Normal fuse
250V 1A
Protects the PCC main PWB and the operation
control PWB form an overcurrent.
DC sub power
PWB
7
F711
DC sub power
primary size fuse
Normal fuse
250V 3.15A
Protects the DC sub power primary side from
an overcurrent.
DC sub power
PWB
8
F101
AC main power
primary side fuse
Normal fuse
125V 20A
Protect the AC main power primary side from
an overcurrent.
Japan
AC main power
primary side fuse
Normal fuse
250V 15A
Protect the AC main power primary side from
an overcurrent.
100V series
AC main power
primary side fuse
Normal fuse
240V 10A
Protect the AC main power primary side from
an overcurrent.
200V series
9
F102
AC main power
primary side fuse
Normal fuse
125V 20A
Protect the AC main power primary side from
an overcurrent.
Japan
AC main power
primary side fuse
Normal fuse
240V 10A
Protect the AC main power primary side from
an overcurrent.
200V series
10
F702
DC main power
+ 5V fuse
Normal fuse
125V 6.3A
Protects the ICU PWB from an overcurrent.
100V series
11
F703
DC main power
+ 5V fuse
Normal fuse