AR-C260/C260M  SETTING AND ADJUSTMENTS  8 - 17
6) With the scanner unit B in contact with the both stoppers on the
CCD mounting plate at the same time, fit the edge of the scanner
unit A with the frame right edge and fix the scanner unit A with the
screw.
1) Make a test chart on A3 (11" x 17") paper as shown below. (Draw a
rectangular with four right angles.)
2) Set the test chart made in procedure 1) on the document table.
(Leave a space of about 30mm between the reference position and
the test chart.) With the document cover open, make a copy on A3
(11" x 17").
3) Check for distortion in the sub scanning direction.
If La = Lb, there is no distortion.
If there is some distortion in the sub scanning direction, perform the fol-
lowing procedures.
4) Loosen either of two fixing screws of the scanner unit drive pulley.
(Either one on the front or the rear side will do.)
5) With the scanner unit drive shaft kept stationary, turn the scanner
unit drive pulley manually to change the parallelism of scanner
units A and B. (Change the relative positions of the scanner unit
drive pulley and the drive shaft.)
6) Tighten the scanner unit drive pulley fixing screw.
Repeat procedures 2) – 6) until the condition of procedure 3) is sat-
isfied.
If the distortion in the sub scanning direction cannot be deleted with the
above procedures, perform ADJ 6D, Scan image distortion adjustment.
ADJ 6B
Copy image sub scanning direction 
distortion adjustment
L
L
L
L
L = 10mm
Lb
La
AR-C260/C260M  SETTING AND ADJUSTMENTS  8 - 18
1) Make a test chart on A3 (11" x 17") paper as shown below. (Draw a
rectangle with four right angles.)
2) Set the test chart made in procedure 1) on the document table.
With the document cover open, make a copy on A3 (11" x 17").
3) Check for distortion in the main scanning direction.
If the four angles of the rectangle on the copy are right angles,
there is no distortion. (Completion of the adjustment)
If there is some distortion in the main scanning direction, perform the
following procedures
4) Check the difference (distortion balance) of left and right images
distortions.
If Lc = Ld, the distortion on the left is equal to that on the right. (The
distortions are balanced.)
If the above condition is satisfied, go to procedure 6).
If the above condition is not satisfied, perform the following procedure.
5) Change the height balance of the front frame side scanner rail.
[Rail adjustment]
1) Make a copy from the table glass, and check the copy output.
In this case, set the test chart correctly. If it is set inclined, the
adjustment cannot be made correctly.
2) If the check result is outside the specified range, perform the
following procedure.
3) Remove the front cabinet on the scanner side, and check the
installing position of the MB rail.
4) Loosen the screw on the right side of the MB rail.
Repeat procedures 2) to 5) until the image distortions are balanced.
6) Without changing the balance between the front frame side scan-
ner rail, change the overall height.
7) Set the test chart made in procedure 1) on the document table, and
make a copy on A3 (11" x 17") paper. Check that the main scan-
ning distortion is within the specified range.
Perform procedures 7) to 8) until the main scanning direction dis-
tortion is in the specified range.
If this adjustment cannot remove the sub scanning direction distortion,
perform ADJ 6D, Scan image distortion adjustment.
If scan image distortion cannot be removed with ADJ 6A, ADJ 6B, and
ADJ 6C, perform this adjustment.
Change the position of the scanner unit distortion adjustment plate on
the right side of the scanner unit so that the scanner image distortion
becomes minimum. The scan image distortion is adjusted by adjusting
the overall mechanical distortion of the scanner unit.
ADJ 6C
Copy image main scanning direction 
distortion adjustment
L
L
L
L
L = 10mm
Lc
Ld
Lc
Ld
Copy A
Copy B
There is no difference 
between the distortion on 
the right and that on the left.
Lc = Ld
There is some difference 
between the distortion on 
the right and that on the left.
Lc 
 Ld
ADJ 6D
Scan image distortion adjustment
A
A
B
C
Scanner adjustment plate WH
B
C
AR-C260/C260M  SETTING AND ADJUSTMENTS  8 - 19
This adjustment must be performed in the following cases:
• When the CCD unit is removed from the machine.
• When the CCD unit is replaced.
• When the copy image focus is improper.
• When the copy magnification ratio in the copy image main scanning
direction is not proper.
• When the MFP main PWB is replaced.
• When the EEPROM of the MFP main PWB is replaced.
• When a U2 trouble occurs.
1) Enter the SIM 48-1 mode.
2) Set the set item B to 50 (initial value).
3) As shown in the figure below, place a scale on the original table.
4) Make a normal copy on A4 paper.
5) Compare the scale image length and the actual scale length.
6) Obtain the main scanning direction copy magnification ratio
according to the following formula.
Main scanning direction copy magnification ratio
=
x 100 [%]
(Example) Fit 10mm of the scale with 10mm of the copied scale and
compare them.
Main scanning direction copy magnification ration
=
x 100 = 1
If the copy magnification ratio is not satisfactory, perform the fol-
lowing procedure.
7) Remove the original guide L and R, and remove the table glass.
8) Remove the dark box cover.
9) Loosen the CCD unit fixing screws.
Draw a marking line on the CCD unit base as shown below in order
to avoid a shift in the optical axis of the CCD unit.
At that time, fix the CCD unit so that it is in parallel with the marked
line in procedure 9).
Never loosen the screws marked with "
."
If one of these screws is loosened, the CCD unit base position
and angle may be changed. If so, it cannot be adjusted in the
market, and therefore the whole scanner unit must be replaced.
10) Slide the CCD unit in the arrow direction (CCD sub scanning direc-
tion) to change the installing position.
When the copy image is longer than the original, move in the direc-
tion of B.
When the copy image is shorter than the original, move in the
direction of A.
One scale of scribe line corresponds to 0.2%.
At that time, fix so that the CCD unit is in parallel with the scales on
the front frame side and on the rear frame side of the CCD unit
base.
At that time, fix the CCD unit so that it is in parallel with the marked
line in procedure 9).
ADJ 7
Copy image focus (main 
scanning direction copy 
magnification ratio) adjustment 
(CCD unit position adjustment)
10
20
30
40
50
60
70
80
90
50
100110
120130140
(Original dimension – Copy dimension)
Original dimension
100 – 99
100
10
20
90
100
110
10
20
90
100
110
100mm scale
(Original)
Copy image
(1mm (1%)
shorter than 
the original)
1.0mm
A
B
AR-C260/C260M  SETTING AND ADJUSTMENTS  8 - 20
11) Make a copy, and check the copy magnification ratio.
If the copy magnification ratio is outside the range of 100% ± 1%,
repeat procedures 9) to 11) until it is in the range.
Note: Due to the structure of the optical system, when the CCD unit
fixing position is changed with SIM 48-1 set to 50, the copy mag-
nification ratio is adjusted to the specified level (100 ± 1.0%) and
the specified resolution is provided.
This adjustment must be performed in the following cases:
• When the copy magnification ratio in the copy image sub scanning
direction is improper.
• When the scanner motor is replaced.
• When a U2 trouble occurs.
• When the MFP main PWB is replaced.
• When the EEPROM of the MFP main PWB is replaced.
Before this adjustment, perform the focus adjustment (CCD unit install-
ing position adjustment).
1) Place a scale on the original table as shown below.
2) Enter the SIM 48-1 mode.
3) Make a normal copy and obtain the copy magnification ratios.
Copy magnification ratio
=
x 100 [%]
4) Check that the copy magnification ratio is within the specified
range (100 ± 1.0%).
If the copy magnification ratio is within the specified range (100 ±
1.0%), the adjustment is completed.
If not, perform the following procedure.
5) Change the scan mode adjustment value of SIM 48-1.
When the adjustment value is increased, the sub scanning direc-
tion copy magnification ratio is increased.
A change in the adjustment value by 1 corresponds to a change in
the copy magnification ratio by about 0.1%.
Repeat procedures 3) to 5) until the coy magnification ratio is
within the specified range (100 ± 0.28%).
Note: Fix the adjustment value of SIM 48-1 adjustment mode (F – R)
to 50.
This adjustment must be performed in the following cases:
When the scanner (reading) section is disassembled.
When the scanner (reading) unit is replaced.
When the RADF section is disassembled.
When the RADF unit is installed.
When the RADF unit is replaced.
When a U2 trouble occurs.
When the MFP main PWB is replaced.
When the EEPROM of the MFP main PWB is replaced.
1) Make a copy in the adjustment chart adjustment mode. (Document
table or RADF)
2) Check the copy image center position.
If A – B = ± 4.0mm, there is no need to adjust.
If the above condition is not satisfied, perform the following proce-
dures.
3) Enter the SIM 50-12 mode.
4) Select the adjustment mode with the scroll key.
5) Enter the adjustment value with the 10-key and press the [OK] key.
The entered value is set.
When the set value is increased, the image is shifted to the rear
side. When the set value is decreased, the image is shifted to the
front side.
When the set value is change by 1, the image is shifted by about
0.4mm.
Repeat procedures 2) to 5) until the above condition is satisfied.
ADJ 8
Sub scanning direction copy 
magnification ratio adjustment
10 20 30 40 50 60 70 80 90 50 100 110 120130 140
(Original dimension – Copy dimension)
Original dimension
10
20
90
100
110
10
20
90
100
110
10
20
90
100
110
(Example 2) 
Copy B
(Longer than 
the original)
(Example 1) 
Copy A
(Shorter than 
the original)
Scale 
(Original)
ADJ 9
Main scanning direction copy 
image position adjustment 
(Scanner (reading) section)
A
B
A – B =   4.0mm
(400%)