11) Select the data file which is to be copied (written) to the Flash
ROM installed to the ICU MAIN PWB Write socket in procedure
1).
– 1 – Double-click the Simulation Command List holder.
– 2 – Double-click the Special (Bear) holder.
– 3 – Double-clock the File Program Download.
– 4 – The message of "Program Download OK ?" is displayed.
Press the OK button.
– 5 – Select the data (PWB name) to be written and click the
START button.
– 6 – Select the data to be written and click the OPEN button.
With the above procedure, downloading (writing to the Flash
ROM) is started.
(NOTE) Selection of data files to be written determines whether a
source ROM (which includes the latest version program
and the Flash ROM copy program) or a ROM which has
only the latest version program is made.
12) Confirm that downloading (copying to the Flash ROM) is com-
pleted on the computer display and on the LCD display.
It normally takes 5 to 7 minutes to copy (write) to the Flash
ROM.
When downloading is normally completed, the following indica-
tions are shown.
*
The Read and Write LED’s on the ICU MAIN PWB are turned
off.
*
"THE PROGRAM WAS COMPLETE" is displayed on the
LCD.
13) Cancel the simulation 49-1 and turn off the power of the
machine.
(NOTE) If the Flash ROM is removed from or installed to the
machine with the machine power ON, the Flash ROM may
be destroyed. Be sure to turn off the power of the machine
before removing or installing the Flash ROM.
14) Remove the Flash ROM (which was upgraded) installed to the
ICU MAIN PWB Write socket in procedure 1).
When another Flash ROM is to be upgraded, install it to the ICU
MAIN PWB Write socket and turn on the power, and perform proce-
dures 11) through 14).
B. Method using two Flash ROM sockets on the
AR-C150 ICU MAIN PWB to copy between Flash
ROM’s
1) Check that the power of the machine is OFF. Install the Flash
ROM (of either of ICU MAIN PWB, PCU MAIN PWB, or operation
control PWB) to the ICU MAIN PWB Write socket.
2) Install the source Flash ROM (which has the program data of
either of ICU MAIN PWB, PCU MAIN PWN, or operation control
PWB) to the ICU MAIN PWB Read socket.
3) Turn on the power of the machine.
Copying is started. When copying is completed, the Read and the
Write LED’s on the ICU MAIN PWB are turned off.
It normally takes 30 to 60 sec to copy (write) to the Flash ROM.
4) Turn off the power of the machine, and remove the Flash ROM’s
from the Read and the Write sockets.
(After work)
1) Installed the copied Flash ROM to the specified PWB.
2) Turn on the power of the machine and check that the machine
operates normally.
3) Use the simulation 22-5 to check each ROM version.
4) Install the shield plate and the stopper shift. (3 screws)
5) Attach the right upper cabinet of the machine. (2 screws)
(NOTE)
The monitor displays before and after and during the Flash ROM
version up (copy) operation are shown below. If the Flash ROM ver-
sion up operation is not completed normally or if the Flash ROM is not
installed to the socket properly, a trouble code is displayed. In that
case, perform the countermeasures shown in the table below.
(1) ICU MAIN PWB monitor LED lighting specification
The monitor LED status during copy (write) operation of PC to
Flash ROM and Flash ROM to Flash ROM is shown below.
"Since, in the copy mode of Flash ROM to Flash ROM, the
machine status is indicated only with the monitor LED, there are
many monitor LED lighting patterns."
"While in the copy mode of PC to Flash ROM, the machine status
is indicated on the operation panel or on the PC monitor display,
there are less monitor LED lighting patterns."
LED 1 
 
LED 2 
 
Write
socket
Read
socket
Copy (write)
mode
LED1 (Read) LED2 (Write)
Operating status Content Remedies
ON Blink ON Blink
Flash ROM to
Flash ROM
When turning on the
power
A target Flash ROM is attached to the Write socket
when the power is turned on.
No target Flash ROM is attached to the Write socket
when the power is turned on.
Insert a target Flash ROM into the
Write socket.
Copy program start The capacity of the target Flash ROM is proper.
The capacity of the target Flash ROM is not proper. Insert a Flash ROM of the required
capacity into the Write socket.
Flash ROM Erase During normal ERASE operation of Flash ROM to be
Abnormal end of
ERASE operation of the
target Flash ROM.
Restart the machine or replace the target Flash ROM.
 
When writing data During data transmission
 
When writing is normally completed
When writing is not normally completed Restart the machine or replace the
target Flash ROM.
When verifying When verifying
 
Normal completion of verify
Abnormal end of verify Restart the machine or replace the
target Flash ROM.
Write complete When writing of all ROM’s is completed.
PC to Flash
ROM
When executing
simulation
"When checking insertion of a target Flash ROM,
insertion of a Flash ROM is detected."
"When checking insertion of a target Flash ROM,
insertion of a Flash ROM is not detected."
Insert a target Flash ROM into the
Write socket.
 
When downloading from
PC
(Except during execution
of ERASE)
Downloading from PC is normally executed.
 
Downloading from PC is failed (in Nack transmission). Execute download again.
Downloading from PC is normally completed.
Flash ROM Erase ERASE operation of the target Flash ROM is normally
executed.
Restart the machine or replace the
target Flash ROM.
When writing data Abnormal end of writing (abnormal writing into Flash
ROM)
Restart the machine or replace the
target Flash ROM.
When verifying When verifying
 
Verifying is normally completed.
Abnormal end of verifying Restart the machine or replace the
target Flash ROM.
Write complete When writing of all Flash ROM’s is completed.
(2) Operation panel display specifications (Simulation 49-1)
The operation panel display status in the copy mode of PC to Flash ROM mode is shown below.
Display message Operation/Content Countermeasures
NOW EXECUTING • • •. The simulation is started.
THIS COPIER IS NOT CONNECTED TO PC. The cable is not connected. "After turning off the power of the copier,
check the connection again."
FLASH ROM ISN’T INSERTED INTO A
CONNECTOR.
No target Flash ROM is inserted into the socket. "After turning off the power of the copier,
insert the Flash ROM."
WAITING FOR START OF SOFTWARE ON THE
PC.
Waiting for start of Flash ROM writing software on the PC. Start the software to write into the Flash
ROM on the PC.
COPIER SIDES WERE IN PREPARATION. Waiting for start of PC software and Flash ROM Erase is not
completed.
COPIER SIDES WERE READY. Waiting for start of PC software and Flash ROM Erase is
completed.
UNSUCCESSFUL IN THE DELETION IN FLASH
ROM.
Erase of the target Flash ROM was failed. Retry or replace the Flash ROM.
WRITE ERROR AROSE. Copy (Write) of the target Flash ROM was failed. Retry or replace the Flash ROM.
VERIFY ERROR. Verify of the target Flash ROM was failed. Retry or replace the Flash ROM.
NOW DOWN LOADING • • •. Downloading of data
TRANSMISSIN ERROR. Data transmission was failed. Retry data transmission or retry
simulation.
THE PROGRAM WAS COMPLETE.
THIS SIMULATION DOES NOT WORK IN THIS
ROM VERSION.
Displayed when the ICU Flash ROM does not conform to this
simulation.
ICU Flash ROM Version UP
"When the machine power is turned off during data transmission, the PC starts data transmission again from the beginning."
Copy (write)
mode
LED1 (Read) LED2 (Write)
Operating status Content Remedies
ON Blink ON Blink
Flash ROM to
Flash ROM
When turning on the
power
A target Flash ROM is attached to the Write socket
when the power is turned on.
No target Flash ROM is attached to the Write socket
when the power is turned on.
Insert a target Flash ROM into the
Write socket.
Copy program start The capacity of the target Flash ROM is proper.
The capacity of the target Flash ROM is not proper. Insert a Flash ROM of the required
capacity into the Write socket.
Flash ROM Erase During normal ERASE operation of Flash ROM to be
Abnormal end of
ERASE operation of the
target Flash ROM.
Restart the machine or replace the target Flash ROM.
 
When writing data During data transmission
 
When writing is normally completed
When writing is not normally completed Restart the machine or replace the
target Flash ROM.
When verifying When verifying
 
Normal completion of verify
Abnormal end of verify Restart the machine or replace the
target Flash ROM.
Write complete When writing of all ROM’s is completed.
PC to Flash
ROM
When executing
simulation
"When checking insertion of a target Flash ROM,
insertion of a Flash ROM is detected."
"When checking insertion of a target Flash ROM,
insertion of a Flash ROM is not detected."
Insert a target Flash ROM into the
Write socket.
 
When downloading from
PC
(Except during execution
of ERASE)
Downloading from PC is normally executed.
 
Downloading from PC is failed (in Nack transmission). Execute download again.
Downloading from PC is normally completed.
Flash ROM Erase ERASE operation of the target Flash ROM is normally
executed.
Restart the machine or replace the
target Flash ROM.
When writing data Abnormal end of writing (abnormal writing into Flash
ROM)
Restart the machine or replace the
target Flash ROM.
When verifying When verifying
 
Verifying is normally completed.
Abnormal end of verifying Restart the machine or replace the
target Flash ROM.
Write complete When writing of all Flash ROM’s is completed.
(2) Operation panel display specifications (Simulation 49-1)
The operation panel display status in the copy mode of PC to Flash ROM mode is shown below.
Display message Operation/Content Countermeasures
NOW EXECUTING • • •. The simulation is started.
THIS COPIER IS NOT CONNECTED TO PC. The cable is not connected. "After turning off the power of the copier,
check the connection again."
FLASH ROM ISN’T INSERTED INTO A
CONNECTOR.
No target Flash ROM is inserted into the socket. "After turning off the power of the copier,
insert the Flash ROM."
WAITING FOR START OF SOFTWARE ON THE
PC.
Waiting for start of Flash ROM writing software on the PC. Start the software to write into the Flash
ROM on the PC.
COPIER SIDES WERE IN PREPARATION. Waiting for start of PC software and Flash ROM Erase is not
completed.
COPIER SIDES WERE READY. Waiting for start of PC software and Flash ROM Erase is
completed.
UNSUCCESSFUL IN THE DELETION IN FLASH
ROM.
Erase of the target Flash ROM was failed. Retry or replace the Flash ROM.
WRITE ERROR AROSE. Copy (Write) of the target Flash ROM was failed. Retry or replace the Flash ROM.
VERIFY ERROR. Verify of the target Flash ROM was failed. Retry or replace the Flash ROM.
NOW DOWN LOADING • • •. Downloading of data
TRANSMISSIN ERROR. Data transmission was failed. Retry data transmission or retry
simulation.
THE PROGRAM WAS COMPLETE.
THIS SIMULATION DOES NOT WORK IN THIS
ROM VERSION.
Displayed when the ICU Flash ROM does not conform to this
simulation.
ICU Flash ROM Version UP
"When the machine power is turned off during data transmission, the PC starts data transmission again from the beginning."
Copy (write)
mode
LED1 (Read) LED2 (Write)
Operating status Content Remedies
ON Blink ON Blink
Flash ROM to
Flash ROM
When turning on the
power
A target Flash ROM is attached to the Write socket
when the power is turned on.
No target Flash ROM is attached to the Write socket
when the power is turned on.
Insert a target Flash ROM into the
Write socket.
Copy program start The capacity of the target Flash ROM is proper.
The capacity of the target Flash ROM is not proper. Insert a Flash ROM of the required
capacity into the Write socket.
Flash ROM Erase During normal ERASE operation of Flash ROM to be
Abnormal end of
ERASE operation of the
target Flash ROM.
Restart the machine or replace the target Flash ROM.
 
When writing data During data transmission
 
When writing is normally completed
When writing is not normally completed Restart the machine or replace the
target Flash ROM.
When verifying When verifying
 
Normal completion of verify
Abnormal end of verify Restart the machine or replace the
target Flash ROM.
Write complete When writing of all ROM’s is completed.
PC to Flash
ROM
When executing
simulation
"When checking insertion of a target Flash ROM,
insertion of a Flash ROM is detected."
"When checking insertion of a target Flash ROM,
insertion of a Flash ROM is not detected."
Insert a target Flash ROM into the
Write socket.
 
When downloading from
PC
(Except during execution
of ERASE)
Downloading from PC is normally executed.
 
Downloading from PC is failed (in Nack transmission). Execute download again.
Downloading from PC is normally completed.
Flash ROM Erase ERASE operation of the target Flash ROM is normally
executed.
Restart the machine or replace the
target Flash ROM.
When writing data Abnormal end of writing (abnormal writing into Flash
ROM)
Restart the machine or replace the
target Flash ROM.
When verifying When verifying
 
Verifying is normally completed.
Abnormal end of verifying Restart the machine or replace the
target Flash ROM.
Write complete When writing of all Flash ROM’s is completed.
(2) Operation panel display specifications (Simulation 49-1)
The operation panel display status in the copy mode of PC to Flash ROM mode is shown below.
Display message Operation/Content Countermeasures
NOW EXECUTING • • •. The simulation is started.
THIS COPIER IS NOT CONNECTED TO PC. The cable is not connected. "After turning off the power of the copier,
check the connection again."
FLASH ROM ISN’T INSERTED INTO A
CONNECTOR.
No target Flash ROM is inserted into the socket. "After turning off the power of the copier,
insert the Flash ROM."
WAITING FOR START OF SOFTWARE ON THE
PC.
Waiting for start of Flash ROM writing software on the PC. Start the software to write into the Flash
ROM on the PC.
COPIER SIDES WERE IN PREPARATION. Waiting for start of PC software and Flash ROM Erase is not
completed.
COPIER SIDES WERE READY. Waiting for start of PC software and Flash ROM Erase is
completed.
UNSUCCESSFUL IN THE DELETION IN FLASH
ROM.
Erase of the target Flash ROM was failed. Retry or replace the Flash ROM.
WRITE ERROR AROSE. Copy (Write) of the target Flash ROM was failed. Retry or replace the Flash ROM.
VERIFY ERROR. Verify of the target Flash ROM was failed. Retry or replace the Flash ROM.
NOW DOWN LOADING • • •. Downloading of data
TRANSMISSIN ERROR. Data transmission was failed. Retry data transmission or retry
simulation.
THE PROGRAM WAS COMPLETE.
THIS SIMULATION DOES NOT WORK IN THIS
ROM VERSION.
Displayed when the ICU Flash ROM does not conform to this
simulation.
ICU Flash ROM Version UP
"When the machine power is turned off during data transmission, the PC starts data transmission again from the beginning."
Page of 7
Display