DOWNLOAD Sharp AR-810 (serv.man20) Service Manual ↓ Size: 3.35 MB | Pages: 91 in PDF or view online for FREE

Model
AR-810 (serv.man20)
Pages
91
Size
3.35 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / RADF (Document feeder)
File
ar-810-sm20.pdf
Date

Sharp AR-810 (serv.man20) Service Manual ▷ View online

AR-651/810  RADF (DOCUMENT FEEDER)  16 - 33
(3) Original jammed not reaching the read sensor
• Jam detection
This jam is detected during the time after an original comes to the 1st roller until it reaches the
read sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the 1st roller to the read sensor plus 60mm.
(4) Original jammed at the read sensor (from the feeding side)
• Jam detection
This jam is detected during the time after an original passes through the 1st roller until it passes
through the read sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the 1st roller to the read sensor plus 30mm.
(5) Original jammed at the read sensor (from the large original exit side)
• Jam detection
This jam is detected during the time after the scanning of an original from the large original exit
side set at the scanning position until the original passes through the read sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for the longest
original (LD) to pass through the read sensor and proceed more 30mm.
16. 6. 3.  Jams at large original exit section
(1) Original jammed not reaching the large original exit sensor (while discharging)
• Jam detection
This jam is detected during the time after an original comes to the 4th roller until it reaches the
large original exit sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the 4th roller to the large original exit sensor plus 30mm.
AR-651/810 RADF (DOCUMENT FEEDER)  16 - 34
(2) Original jammed at the large original exit sensor (while discharging)
• Jam detection
This jam is detected during the time after the leading edge of an original passes the position
20mm further from the 4th roller until it passes through the large original exit sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for the leading edge
of an original to proceed the distance from the position 20mm further from the 4th roller to the end
of the large original exit sensor plus 60mm.
(3) Original jammed not reaching the large original exit sensor (while registering the back side)
• Jam detection
This jam is detected during the time after the back side registration or transportation to the 1st
roller starts until an original reaches the large original exit sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the large original exit roller to the large original exit sensor plus 60mm.
16. 6. 4.  Jams at small original reverse section
(1) Original jammed not reaching the small original reverse sensor
     (to the small original reverse side)
• Jam detection
This jam is detected during the time after an original reaches the intermediate transport roller until
it reaches the small original reverse sensor.
• Jam pulse setting
The setting value of the jam pulse is equivalent number of pulses it takes for an original to proceed
the distance from the intermediate transport roller to the small original reverse sensor plus 60mm.
(2) Original jammed at the small original reverse sensor (to the small original reverse side)
• Jam detection
This jam is detected during the time after the deceleration, which is set to finish at the position
20mm short of the small original reverse sensor, starts until an original passes through the small
original reverse sensor.
• Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an original
to proceed 60mm.
AR-651/810  RADF (DOCUMENT FEEDER)  16 - 35
(3) Original jammed not reaching the small original reverse sensor
 (from the small original reverse side to the small original exit side)
• Jam detection
This jam is detected during the time after discharging starts at the small original reverse section
until an original reaches the small original reverse sensor.
• Jam timer setting
The setting value for the jam timer is three times as much time as mentioned above.
(4) Original jammed at the small original exit sensor
 (from the small original reverse side to the small original exit side)
• Jam detection
This jam is detected during the time after an original reaches the small original exit sensor until it
passes through the small original reverse sensor.
• Jam timer setting
The setting value for the jam timer is 1.5 times as much time as it takes for an LT, which is the
longest original (of all kinds of small-sized paper) when discharging small originals, to pass
through the small original reverse sensor.
16. 6. 5.  Jams at small original exit section
(1) Original jammed not reaching the small original exit sensor
(from the intermediate transport section side)
• Jam detection
This jam is detected during the time after an original reaches the intermediate transport roller until
it reaches the small original exit sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the intermediate transport roller to the small original exit sensor plus
60mm.
(2) Original jammed at the small original exit sensor (from the intermediate transport section side)
• Jam detection
This jam is detected during the time after the deceleration, which is set to finish at the position
20mm short of the small original exit sensor, starts until an original passes through the small
original exit sensor.
• Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an original
to proceed 60mm.
AR-651/810 RADF (DOCUMENT FEEDER)  16 - 36
(3) Original jammed not reaching the small original exit sensor (from the small original reverse side)
• Jam detection
This jam is detected during the time after an original reaches the small original reverse sensor
until it reaches the small original exit sensor.
• Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an original
to proceed 60mm.
(4) Original jammed at the small original exit sensor (from the small original reverse side)
• Jam detection
This jam is detected during the time after the deceleration, which is set to finish at the position
20mm short of the small original exit sensor, starts until an original passes through the small
original exit sensor.
• Jam timer setting
The setting value for the jam timer is the time mentioned above plus necessary time for an original
to proceed 60mm.
16. 6. 6.  Jams at intermediate transport section
(1) Original jammed not reaching the intermediate transport sensor
• Jam detection
This jam is detected during the time after an original reaches the 3rd roller until it reaches the
intermediate transport sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for an original to
proceed the distance from the 3rd roller to the intermediate transport sensor plus 30mm.
(2) Original jammed at the intermediate transport sensor
• Jam detection
This jam is detected during the time after the trailing edge of an original passes the position 20mm
further from the 3rd roller until it has passed through the intermediate transport sensor.
• Jam pulse setting
The setting value for the jam pulse is the equivalent number of pulses it takes for the trailing edge
of an original to proceed the distance from the position 20mm further from the 3rd roller to the
intermediate transport sensor plus 60mm.
Page of 91