Sharp AR-5320E (serv.man4) Service Manual ▷ View online
AR-5316E/5320E EXTERNAL VIEWS AND INTERNAL STRUCTURES 4-1
[4] EXTERNAL VIEWS AND INTERNAL STRUCTURES
1. Appearance
2. Internal
1
Glass cleaner
(when the SPF is installed)
(when the SPF is installed)
2
Document feeder cover (when the SPF
is installed) /document cover
is installed) /document cover
3
Document glass
4
Handles
5
Power switch
6
Operation panel
7
Paper output tray
8
Front cover
9
Paper trays
10
Side cover
11
Side cover handle
12
Bypass tray guides
13
Bypass tray
14
Bypass tray extension
15
Charger cleaner
16
USB 1.1 connector
17
Parallel connector
18
USB 20 connector (when the dual
function board is installed)
function board is installed)
19
Document feeder tray
(when the SPF is installed)
(when the SPF is installed)
20
Original guides
(when the SPF is installed)
(when the SPF is installed)
21
Feeding roller cover
(when the SPF is installed)
(when the SPF is installed)
22
Right side cover
(when the SPF is installed)
(when the SPF is installed)
23
Exit area
(when the SPF is installed)
(when the SPF is installed)
24
Toner cartridge lock release lever
25
Toner cartridge
26
Roller rotating knob
27
Fusing unit release levers
28
Photoconductive drum
29
Fusing unit paper guide
6
15
7
13
14
8
2
2
3
5
10
17
16
11
12
9
4
4
1
18
21
19
24
25
23
22
26
27
20
29
28
[04]EXTERNALVIEWS.fm 1 ページ 2006年12月1日 金曜日 午後2時17分
AR-5316E/5320E EXTERNAL VIEWS AND INTERNAL STRUCTURES 4-2
3. Operation Section
1
ON LINE key/indicator
2
DUAL PAGE COPY key/indicator
3
XY-ZOOM key/indicator
20
ORIGINAL SIZE ENTER key /
ORIGINAL SIZE indicators
ORIGINAL SIZE indicators
21
PAPER SIZE indicators
23
SPF indicator
(when the SPF is installed)
(when the SPF is installed)
26
Paper feed location / misfeed location
indicators
indicators
27
PRESET RATIO selector keys /
indicators
indicators
4
SORT/GROUP key / indicators(when the
dual function board is installed)
dual function board is installed)
5
ORIGINAL DATA indicator(when the
dual function board is installed)
dual function board is installed)
6
2 IN 1 / 4 IN 1 key / indicators(when the
dual function board is installed)
dual function board is installed)
7
ERASE key / indicators(when the dual
function board is installed)
function board is installed)
8
MARGIN SHIFT key / indicator(when the
dual function board is installed)
dual function board is installed)
9
AUTO/TEXT/PHOTO key / indicators
10
AUDIT CLEAR key
11
AUTO PAPER SELECT indicator
12
Alarm indicators
13
POWER SAVE indicator
14
Display
15
Copy ratio display key
16
ZOOM indicator
17
Zoom keys
18
INTERRUPT key / indicator
19
Light and Dark keys / indicators
20
ORIGINAL SIZE ENTER key /
ORIGINAL SIZE indicators
ORIGINAL SIZE indicators
21
PAPER SIZE indicators
22
PAPER SIZE ENTER key
23
SPF indicator (when the SPF is
installed)
installed)
24
TRAY SELECT key
25
AUTO IMAGE key / indicator
26
Paper feed location / misfeed location
indicators
indicators
27
PRESET RATIO selector keys /
indicators
indicators
28
Numeric keys
29
READ-END key
30
START key / indicator
31
CLEAR ALL key
32
CLEAR key
200%
50%
141
95
77
64
64
129
121
11
X
17
8½
X
14
8½
X
11
8½
X
11
8½
X
5½
EXTRA
8½
X
13
100%
The example of a display of inch series
The indications of the operation panel may differ
depending on the country and the region.
depending on the country and the region.
AR-5316E/
2
3
1
23
26
23
26
27
20
21
INTERRUPT
ZOOM
1 3 5
25 400%
AUTO
ENTER
AUTO
ACC.#-C
AUTO %
A3
A4
A4
A5
B4
A4
A4
A5
B4
EXTRA
200%
50%
141
86
81
70
70
122
115
100%
READ-END
DATA
When there are two or more paper trays
Not used for this machine.
9 10
4
5
6
7 8
11
12
13
14
15
16
17
19
20
21 22 23 24
25
26
27
28
29
30
31 32
18
[04]EXTERNALVIEWS.fm 2 ページ 2006年12月1日 金曜日 午後2時17分
AR-5316E/5320E MAINTENANCE 10-1
[10] MAINTENANCE
1. Maintenance table
X:Check(Clean, adjust, or replace when required.)
O:Clean :Replace :Adjust :Lubricate
*1:Recommendable replacement time:50K(A4,5%print)
Unit name
Part name
When calling
50K
100K
150K
Drum peripheral
OPC drum
-
Cleaning blade
-
Side seal F/R
X
X
X
X
MC unit
X
(MC charging electrode)
-
(
)
(
)
(
)
(MC grid)
-
(
)
(
)
(
)
(MC case)
-
(
)
(
)
(
)
Transfer wire
O
O
O
O
Transfer paper guide
O
O
O
O
MC guide sheet (Cleaning blade attached)
-
Drum fixing plate B
X
Process frame unit
X
X
X
Discharge holder
O
O
O
O
Separation pawl
Star ring x 2 pcs
Star ring x 2 pcs
X
Developing section
Developer
-
DV seal
-
X
X
DV under seal
-
-
-
DV side seal
-
X
X
Side Mylar
-
-
-
Optical section
Lamp unit
Reflector
O
O
O
O
Mirror
O
O
O
O
No.2/3 mirror unit
Mirror
O
O
O
O
Pulley
X
X
X
X
CCD peripheral
Lens
O
O
O
O
Glass
Table glass
O
O
O
O
White Plate
O
O
O
O
Other
Drive wire
X
X
X
X
Rail
X
X
X
X
Document cover
O
O
O
O
Document size sensor
O
O
O
O
LSU
Dust-proof glass
O
O
O
O
Paper feed section
Multi paper feed section
Take-up roller(manual / SPF)
O
O
O
O
Paper feed roller
O
O
O
O
Spring clutch
O
O
O
O
Paper transport section
PS roller
O
O
O
O
Transport (paper exit) rollers
O
O
O
O
Spring clutch
O
O
O
O
Fusing section
Upper heat roller
O
O
O
Pressure roller
O
O
O
O
Pressure roller bearing
X
X
X
O
Upper separation pawl
X
X
X
O
Lower separation pawl
X
X
X
O
Cleaning pad
X
X
X
Drive section
Gears
X
X
X
X
Belts
X
X
X
O
Paper exit section
Ozone filter*1
X
X
X
X
[10]MAINTENANCE.fm 1 ページ 2006年12月8日 金曜日 午前11時1分
AR-5316E/5320E MAINTENANCE 10-2
2. Maintenance display system
*1: Installation of a new toner cartridge allows to display the remaining
quantity.
3. Note for replacement of consumable parts
A. Toner cartridge
When a waste toner cartridge is removed from the machine, it must be
put in a polyethylene bag to avoid scattering of toner.
B. DV cartridge
Do not shake or put up the developer cartridge. Otherwise developer
may scatter.
C. DV seal attachment procedure
1) When attaching the DV side Mylar, check the position shown in the
figure below and attach it properly.
2) When attaching the DV side sheet, check the position shown in the
figure below and attach it properly.
(First of all, attach the DV side Mylar.)
(First of all, attach the DV side Mylar.)
*
Be sure to attach the DV side sheet so that the notch is on the
outside.
Toner
Life,
16K
Remaining
quantity
check *1
quantity
check *1
a. Press and hold the density adjustment
LIGHT key for more than 5 sec, and the
machine will enter the user program
mode.
machine will enter the user program
mode.
b. Press and hold the "%" key for more
than 5 sec, and the remaining quantity
will be displayed on the copy quantity
display in one of the following levels:
(Remaining quantity display levels:
100%, 75%, 50%, 25%, 10%, LO)
will be displayed on the copy quantity
display in one of the following levels:
(Remaining quantity display levels:
100%, 75%, 50%, 25%, 10%, LO)
c. Press the density adjustment LIGHT
key to cancel.
Remaining
quantity
quantity
NEAR EMPTY
About 10%
About 10%
EMPTY
LED
ON
Flash
Machine
Operation allowed
Stop
Developer
Life
50K
LED
ON at 50K of the
developer count
developer count
Machine
Selection is available between Not Stop
and Stop by Service Simulation (SIM 26-
37) Setup.
(If Stop is selected, the LED will flash and
stop at 50K.)
*
and Stop by Service Simulation (SIM 26-
37) Setup.
(If Stop is selected, the LED will flash and
stop at 50K.)
*
Default: Not Stop
*
Clear: SIM 42-1
Maintenance LED
Selection is available among 50K, 25K,
10K, 7.5K, 5K, and Not stop with SIM 21-
1.
*
10K, 7.5K, 5K, and Not stop with SIM 21-
1.
*
Default: 50K
*
Clear: SIM 20-1
Machine
Not stop
[10]MAINTENANCE.fm 2 ページ 2006年12月8日 金曜日 午前11時1分
Click on the first or last page to see other AR-5320E (serv.man4) service manuals if exist.