Sharp AR-5320E (serv.man3) Service Manual ▷ View online
AR-5316/5320 SIMULATIONS 7-3
06
02
Resist roller solenoid operation
check
check
When the [START] key is pressed in the sub code input state, the resist solenoid (RRS) turns ON for
500ms and OFF for 500ms. This operation is repeated 20 times.
After completion of the process, the machine goes into the sub code input standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
500ms and OFF for 500ms. This operation is repeated 20 times.
After completion of the process, the machine goes into the sub code input standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
10
Cassette semi-circular roller
cleaning
cleaning
First of all, remove the developer unit.
Enter the simulation code, specify the cassette to be cleaned with the tray select key, and press
START button. The main motor rotates to move the cassette semi-circular roller by half circle and
make the roller face downward.
After completion of cleaning, when INTERRUPT key is pressed, the machine goes into the sub code
entry standby mode and the roller returns to the original positions.
To clean another roller continuously, press INTERRUPT key to return the roller to the original
position, and execute the simulation again.
During the operation, the sub code is displayed on the display.
*
Enter the simulation code, specify the cassette to be cleaned with the tray select key, and press
START button. The main motor rotates to move the cassette semi-circular roller by half circle and
make the roller face downward.
After completion of cleaning, when INTERRUPT key is pressed, the machine goes into the sub code
entry standby mode and the roller returns to the original positions.
To clean another roller continuously, press INTERRUPT key to return the roller to the original
position, and execute the simulation again.
During the operation, the sub code is displayed on the display.
*
When CA key is pressed, the simulation mode is terminated.
However, the roller returns to the original position by the initial operation.
08
01
Developing bias output
When the [START] key is pressed, the developing bias signal is turned ON for 30 sec.
However, to calculate the actual output value is calculated, execute SIM25-01.
After completion of the process, the machine goes into the sub code input standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
However, to calculate the actual output value is calculated, execute SIM25-01.
After completion of the process, the machine goes into the sub code input standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
02
Main charger output (Grid = HIGH) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage
HIGH mode. After completion of the process, the machine goes into the sub code input standby
mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
03
Main charger output (Grid = LOW) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage
LOW mode. After completion of the process, the machine goes into the sub code input standby
mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
06
Transfer charger output
Select an output mode with the [Mode select] key and press the [START] key. The transfer charger
output is delivered for 30 sec in the selected mode.
After 30 sec of transfer charger output, the machine goes into the sub code entry standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
output is delivered for 30 sec in the selected mode.
After 30 sec of transfer charger output, the machine goes into the sub code entry standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
22
01
Maintenance counter display
The maintenance counter value is displayed. (Alternate display by 3 digits)
04
Jam total counter display
The jam total counter value is displayed. (Alternate display by 3 digits)
05
Total counter display
The total counter value is displayed. (Alternate display by 3 digits)
06
Developing counter display
The developing counter data is acquired and displayed on the 7-seg display. (Alternate display by 3
digits)
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
digits)
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
08
SPF counter display
The SPF counter value is displayed. (Alternate display by 3 digits)
14
P-ROM version display
The P-ROM version is displayed on the copy quantity display. The main code and the sub code are
alternatively displayed by 2 digits. The display interval is same as that of the counter display.
By pressing the fixed magnification ratio key, each version display is switched.
alternatively displayed by 2 digits. The display interval is same as that of the counter display.
By pressing the fixed magnification ratio key, each version display is switched.
17
Copy counter display
The copy counter value is displayed. (Alternate display by 3 digits) When the [Interrupt] key is
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
18
Printer counter display
The printer counter value is displayed. (Alternate display by 3 digits)When the [Interrupt] key is
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
21
Scanner counter display
The scanner counter value is displayed. (Alternate display by 3 digits)When the [Interrupt] key is
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
Main
code
code
Sub
code
Contents
Details of operation
•Small size is Letter R (A4R) or smaller.
Display lamp
Output mode
AE mode lamp
AE mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamp
AE mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamp
Normal size width: Front surface
Small size width: Front surface
Manual paper feed mode
Small size width: Front surface
Manual paper feed mode
Display lamp (AB series)
Display lamp (Inch series)
Displayed version
141%
141%
Machine program
[07]SIMULATIONS.fm 3 ページ 2003年12月19日 金曜日 午後3時26分
AR-5316/5320 SIMULATIONS 7-4
22
22
SPF jam counter display
The SPF jam counter value is displayed. (Alternate display by 3 digits)When the [Interrupt] key is
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
44
34
Transfer current setting
Used to set the transfer current for the front surface and that for the back surface. When this
simulation is executed, the current set value is displayed on the 7-seg display. Select the set value
with the zoom (Up/Down) keys and press the [START] key, and the set content is written into the
EEPROM and the machine goes into the sub code input standby mode. Press the [Mode select] key
to select each setting mode. At that time, the setup content is written into the EEPROM.
The set range is 90uA ~ 360uA in the increment of 10uA.
simulation is executed, the current set value is displayed on the 7-seg display. Select the set value
with the zoom (Up/Down) keys and press the [START] key, and the set content is written into the
EEPROM and the machine goes into the sub code input standby mode. Press the [Mode select] key
to select each setting mode. At that time, the setup content is written into the EEPROM.
The set range is 90uA ~ 360uA in the increment of 10uA.
*
Small size paper must be Letter R (A4R) or smaller.
*
For the special size of tray, use the normal size width.
49
01
Flash ROM program writing mode
(Operating procedure)
When this simulation is executed, "d" is displayed on the copy quantity display and the machine
enters the Flash ROM program writing mode. Use the writing tool on the PC to write the program.
During writing, the display is made as follows. After completion of downloading, turn OFF/ON the
power to reset.
When this simulation is executed, "d" is displayed on the copy quantity display and the machine
enters the Flash ROM program writing mode. Use the writing tool on the PC to write the program.
During writing, the display is made as follows. After completion of downloading, turn OFF/ON the
power to reset.
*
"*" in the error display indicates the error position.
12
Standby mode fusing fan RPM
setting
setting
When this simulation is executed, the currently set code number is displayed.
When [MODE SELECT] key is pressed, the normal setting and the high fusing temperature setting
are switched alternatively.
Enter the code number and press START key, and the number is written into the EEPROM and the
machine goes into the sub code entry standby mode.
When [MODE SELECT] key is pressed, the normal setting and the high fusing temperature setting
are switched alternatively.
Enter the code number and press START key, and the number is written into the EEPROM and the
machine goes into the sub code entry standby mode.
Main
code
code
Sub
code
Contents
Details of operation
Display lamp
Setting mode
AE mode lamp
AE mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamps
AE mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamps
Normal size width: Front
Small size width: Front
Manual paper feed
Small size width: Front
Manual paper feed
Status
Copy quantity display
Pre-heat lamp
Ready lamp
Download data reception
Data delete start
Data writing (Boot section)
Data writing (Program section)
Sum check
Completion of downloading
Error status
Data delete start
Data writing (Boot section)
Data writing (Program section)
Sum check
Completion of downloading
Error status
"d"
"d"
"d"
"d"
"d"
"OFF"
"*E"
"d"
"d"
"d"
"d"
"OFF"
"*E"
ON
ON
Flash
Flash
ON
OFF
OFF
ON
Flash
Flash
ON
OFF
OFF
OFF
ON
OFF
Flash
ON
OFF
OFF
ON
OFF
Flash
ON
OFF
OFF
00
Data receive error
07
Sum check error (Program section)
02
FLASH ROM delete error
08
Sum check error (EEPROM section)
03
FLASH ROM write error (Boot section)
09
E2PROM verify error
04
FLASH ROM write error (Program section)
0b
E2PROM verify error
05
Sum check error (Loader section)
0F Download data length error
06
Sum check error (Boot section)
Display lamp
Setting mode
Default
AE mode lamp
Normal temperature control (190°C or less)
Low speed rotation
TEXT mode
Fusing temperature of 190°C or above
High speed rotation
Code number
Setting
0
1
1
Low speed rotation
High speed rotation
High speed rotation
[07]SIMULATIONS.fm 4 ページ 2003年12月19日 金曜日 午後3時26分
AR-5316/5320 SIMULATIONS 7-5
51
02
Resist amount adjustment
Used to adjust the contact pressure of the machine resist roller and the RSPF resist roller onto the
paper.
(Operating procedure)
When this simulation is executed, the current set value is displayed.
When the exposure mode key is pressed, the following set items are changed sequentially. Enter an
adjustment value with the 10-key and press the [START] key, and the entered value will be saved and
a copy will be made. (Adjustment range: 1 ~ 99, Default: 50)
When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
paper.
(Operating procedure)
When this simulation is executed, the current set value is displayed.
When the exposure mode key is pressed, the following set items are changed sequentially. Enter an
adjustment value with the 10-key and press the [START] key, and the entered value will be saved and
a copy will be made. (Adjustment range: 1 ~ 99, Default: 50)
When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
Supported for the installed models only. Skipped for the models without installation.
53
10
SPF scan position change-over
setting
setting
Used to change over the scan position depending on that the SPF unit and the SPF document glass
holder section are of anti-dirt glass or not.
When this simulation is executed, the currently set code number is displayed.
Enter the code number corresponding to the SPF unit to be used and press [START] key, and the
setting will be changed over.
holder section are of anti-dirt glass or not.
When this simulation is executed, the currently set code number is displayed.
Enter the code number corresponding to the SPF unit to be used and press [START] key, and the
setting will be changed over.
Though this setting is changed, the other set values are not affected. (The other set values remain
unchanged.)
When replacing and installing the SPF unit, it is recommendable to use this simulation to set the
scan position and execute the scan position automatic adjustment.
unchanged.)
When replacing and installing the SPF unit, it is recommendable to use this simulation to set the
scan position and execute the scan position automatic adjustment.
64
01
Self print
The optical system status is ignored and a self print is made. Also when a print command is sent
from the host, printing is performed.
from the host, printing is performed.
(Operating procedure)
When this simulation is executed, warm-up is performed and the ready lamp is lighted.
(However, the scanner is invalid and no initial operation is made.)
Enter the code number with the 10-key, and select a cassette with the cassette select key and press
the [START] key. The selected cassette start paper feed and printing is performed in the selected
pattern.
(However, the scanner is invalid and no initial operation is made.)
Enter the code number with the 10-key, and select a cassette with the cassette select key and press
the [START] key. The selected cassette start paper feed and printing is performed in the selected
pattern.
*
Only the tray lamp and the online lamp are lighted, and no other lamps are lighted.
Printing is made in 1 by 2 mode, where one line is printed and the following two liens are not printed,
or in the grid pattern.
or in the grid pattern.
*
Input disable for 4 ~ 99
*
Print data are made on A3 size. (A3 paper is preferable.)
Main
code
code
Sub
code
Contents
Details of operation
Lighting lamp
Adjustment mode
AE, Main cassette lamp
AE, 2nd cassette lamp
AE, Manual paper feed lamp
AE, TEXT, PHOTO lamps
AE, 2nd cassette lamp
AE, Manual paper feed lamp
AE, TEXT, PHOTO lamps
Main cassette paper feed
2nd cassette paper feed
Manual paper feed
SPF document feed (Front surface)
Code No.
Mode
0
Set to the scan position of the current mass production SPF unit. (Default)
1
Set to the scan position of the ant-dirt SPF unit.
Code number
Pattern
0
1
2
3
1
2
3
1 by 2
Grid pattern
White paper
Black background
Grid pattern
White paper
Black background
[07]SIMULATIONS.fm 5 ページ 2003年12月19日 金曜日 午後3時26分
AR-5316/5320 USER PROGRAMS 8-1
[8] USER PROGRAMS
The user programs allow the parameters of certain functions to be set, changed, or canceled as desired.
1. List of user programs
This copier has the following user programs.
*1 On models with a SPF.
*2 On model with the two trays.
Program name
Program
No
Description
Default
Parameters
Auto clear time
1
"Auto clear time" automatically returns the copy settings to the initial
settings when a certain period of time elapses after a copy is made.
This program is used to select the period of time. "Auto clear time"
can also be disabled.
settings when a certain period of time elapses after a copy is made.
This program is used to select the period of time. "Auto clear time"
can also be disabled.
60sec
1 (OFF)
2 (10sec)
3 (20sec)
4 (60sec)
5 (90sec)
6 (120sec)
Preheat mode
2
This function automatically switches the machine to a low power
consumption state if the set duration of time elapses without the
machine being used when the power is on.
The POWER SAVE indicator lights up, however, the keys on the
operation panel can be used. Normal operation automatically
resumes when a key on the operation panel is pressed, a print job is
received or an original is placed.
consumption state if the set duration of time elapses without the
machine being used when the power is on.
The POWER SAVE indicator lights up, however, the keys on the
operation panel can be used. Normal operation automatically
resumes when a key on the operation panel is pressed, a print job is
received or an original is placed.
1min
1 (1min)
2 (5min)
3 (30min)
4 (60min)
5 (120min)
6 (240min)
Auto power shut-off timer
3
This function automatically switches the machine to a state that
consumes even less power than preheat mode if the set duration of
time elapses without the machine being used when the power is on.
All lights except the POWER SAVE indicator and ON LINE indicator
go off. To resume normal operation, press the [START] key. Normal
operation also resumes automatically when a print job is received or
scanning is begun from a computer. While in auto power shut-off
mode, no keys (except the [START] key) can be used.
consumes even less power than preheat mode if the set duration of
time elapses without the machine being used when the power is on.
All lights except the POWER SAVE indicator and ON LINE indicator
go off. To resume normal operation, press the [START] key. Normal
operation also resumes automatically when a print job is received or
scanning is begun from a computer. While in auto power shut-off
mode, no keys (except the [START] key) can be used.
5min
1 (5min)
2 (30min)
3 (60min)
4 (120min)
5 (240min)
Stream feeding mode *
1
4
When copying using the SPF, during the period of time that the SPF
indicator blinks after an original has been scanned (about 5
seconds), a subsequent original can be placed and automatically
fed into the machine.
indicator blinks after an original has been scanned (about 5
seconds), a subsequent original can be placed and automatically
fed into the machine.
OFF
0 (OFF)
1 (ON)
Auto power shut-off
setting
setting
5
Use this setting to enable or disable auto power shut-off.
ON
0 (OFF)
1 (ON)
Auto paper select mode *
2
8
This function automatically selects paper that is the same size as
the original placed in the SPF, or the same size as that selected with
the [ORIGINAL SIZE ENTER] key. The function can be disabled.
the original placed in the SPF, or the same size as that selected with
the [ORIGINAL SIZE ENTER] key. The function can be disabled.
ON
0 (OFF)
1 (ON)
Auto tray switching *
2
9
If the paper runs out during printing and there is paper of the same
size and orientation in another tray, this function automatically
switches to that tray (excluding the bypass tray). The function can be
disabled.
size and orientation in another tray, this function automatically
switches to that tray (excluding the bypass tray). The function can be
disabled.
ON
0 (OFF)
1 (ON)
Auditing mode
10
Use to enable or disable "Auditing mode".
"Auditing mode" is initially disabled.
"Auditing mode" is initially disabled.
OFF
0 (OFF)
1 (ON)
Account number entry
11
Use to set up account numbers.
Up to 20 accounts can be established.
Up to 20 accounts can be established.
-
-
Account number change
12
Use to change an account number.
-
-
Account number deletion
13
Use to delete an account number.
A single account number can be deleted, or all account numbers at
once.
A single account number can be deleted, or all account numbers at
once.
Delete
single
account
0 (Delete single account)
1 (Delete all accounts)
Number of copies per
account
account
14
This displays the number of copies made by each account.
The maximum count is 49,999. If this number is exceeded, the count
will start over from 0.
The maximum count is 49,999. If this number is exceeded, the count
will start over from 0.
-
-
Resetting account
15
Use to reset the copy count of an account to 0.
The copy count of a single account or of all accounts can be reset.
The copy count of a single account or of all accounts can be reset.
Reset single
account
0 (Reset single account)
1 (Reset all accounts)
Resolution in Auto/Text
mode
mode
23
This setting is used to change the copy resolution in AUTO and
TEXT mode from 600 x 300 dpi to 600 x 600 dpi
(high-quality mode).
Scanning is slower when high-quality mode is used.
TEXT mode from 600 x 300 dpi to 600 x 600 dpi
(high-quality mode).
Scanning is slower when high-quality mode is used.
300dpi
1 (300dpi)
2 (600dpi)
[08]USERPROGRAMS.fm 1 ページ 2003年12月19日 金曜日 午後3時27分
Click on the first or last page to see other AR-5320E (serv.man3) service manuals if exist.