1.
MEASURE TO ALLEVIATE PROBLEMS OF ELECTRICAL
NOISE.
2.
MEASURE TO IMPROVE SAFETY PERFORMANCE.
3.
MEASURE TO ALLEVIATE PROBLEMS OF JAMS IN THE ADU.
1. Measure to alleviate problems of electrical noise.
1.Model Name:
AR5132 (Only for machines of the 200 V series)
2.General:
The addition of the parts listed below have been carried out as a measure to alleviate
problems of electrical noise.
1) The addition of a ferrite core has been carried out to the optical main harness.
2) The addition of a ferrite core has been carried out to the main switch harness.
Sharp Electronics (UK) Ltd., Technical Services Group
Date:
17 August 1999
Model:
AR5132
Ref:
033
Colour: White
Page:
1 of 5
TECHNICAL BULLETIN
ICU interface harness
(DHAI-2778FCZZ)
Ferrite core
(RCORF6666RCZZ)
Optical main harness
(DHAI-2779FCZZ)
*
Care should be exercised to attach the ferrite core to the harness of the
interface connector (12 pin) of the ICU interface harness and the optical
main harness (indicated by the double arrow in the figure above).
Power supply SW
Ferrite core(SFC-8)
RCORF6666RCZZ
Main SW harness
(DHAI-2773FCZZ)
Paper delivery side
(This figure is drawn as if looked at from the front.)
3) The addition of a ferrite core has been carried out to the harness (on the BC side)
between the TC case unit and the high voltage PWB.
4) A change has been carried out in the position of the attached core of the interface
harness between the ICU and the PCU. The addition of a binding band has also been
carried out.
5) The addition of a binding band has been carried out to the grouped optical main
harness, ICU interface harness, and OP flat cable.
Sharp Electronics (UK)Ltd., Technical Services Group
Charger case
High voltage PWB
(RTRNZ0509FCZZ)
Ferrite core (SFC-8)
RCORF6666RCZZ (Made by Kitagawa)
*
Care should be exercised to attach the ferrite core to the harness between
the wire saddle of the harness on the BC side, and the TC case unit.
White
Blue
Wire saddle
Snap band
Core (RCORF0015FCZZ)
Interface harness between
the ICU and the PCU
(DHAI-2778FCZZ)
Snap band
(Already attached to harness.)
Core
(RCORF0015FCZZ)
Convex
(LBNDJ0013FCZ1)
Operation main
interface harness
(DHAI-2660FCZZ)
Binding band
(LBNDJ0013FCZ1)
Bound in approximately the
center of the vinyl tape.
Optical main harness
(DHAI-2779FCZZ)
ICU interface harness
(DHAI-2778FCZZ)
*
Care should be exercised to cut away any
unnecessary portion of the binding band.
6) The addition of a ferrite core has been carried out to the inner harness of the optical
unit.
3.Action:
From 1997 March production.
2. Measure to improve safety performance.
1.Model Name:
AR5132 (Only for machines of the 200 V series)
2.General:
There was a possibility of the machine short circuiting if contact with the coil on the NF PWB
when attaching the rear cabinet while the power supply cord is plugged into an outlet. As a
measure to alleviate this danger, the addition of a protect sheet has been carried out. At the
same time, a change has also been carried out in the wire saddle. (Note: there has been no
change carried out in the part codes in accordance with these changes.)
3.Action:
From 1997 May production.
Sharp Electronics (UK)Ltd., Technical Services Group
Ferrite core
(RCORF0015FCZZ)
NF PWB protect sheet
When carrying out service or
maintenance operations, care
should be exercised in following the
instructions described in the service
manual and the warning label, and
the AC cord should always be pulled
out of the electrical outlet before
commencing.
3. Measure to alleviate problems of jams in the ADU.
1.Model Name:
AR5132
2.General:
1) There is a possibility of jams occurring due to the DPPD2 actuator failing to
operate as a result of the angle of the copy paper flow. As a measure to alleviate this
problem a change in the angle of the DPPD2 actuator has been carried out with the
actuator sheet to facilitate operation of the DPPD2 actuator
2) The addition of a gasket has been carried out to reinforce the grounding between the
machine and the ADU during double side copy operations.
1) Method of attaching the actuator sheet
2) Paper transport P/G upper unit in the ADU
3.Action:
From the start of 1997 February production.
Sharp Electronics (UK)Ltd., Technical Services Group
Actuator sheet
Back side of the center tray
PE actuator ADU attachment section.
Shaft
Moveable
ADU frame R
Gasket
Paper transport
P/G upper unit
F side
R side
Added gasket
R side view
Caution 1: The gasket should be attached with
double-sided tape to the paper transport
P/G upper unit side.
Caution 2: Move the paper transport P/G upper unit,
and attach so that the gasket and the ADU
frame Fare always in contact.
Caution 3: The gasket attachment standard
should be in contact with the shaft.
Page of 5
Display

Sharp AR-5132 (serv.man103) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp AR-5132 (serv.man103) Service Manual ↓ Size: 192.54 KB | Pages: 5 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp AR-5132 (serv.man103) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-5132 (serv.man103) Copying Equipment. Information contained in Sharp AR-5132 (serv.man103) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.