DOWNLOAD Sharp AR-407 (serv.man86) Service Manual ↓ Size: 12.84 KB | Pages: 2 in PDF or view online for FREE

Model
AR-407 (serv.man86)
Pages
2 Few pages! See other manuals at the bottom of the first or last page.
Size
12.84 KB
Type
PDF
Document
Regulatory Data
Brand
Device
Copying Equipment / MSDS F-00881
File
ar-407-sm86.pdf
Date

Sharp AR-407 (serv.man86) Regulatory Data ▷ View online

S  H  A  R  P
    Data Revised :
    Date Issued  : Dec.  1, 1998
MATERIAL  SAFETY  DATA  SHEET  (1/2)
                                                                                                                                                       MSDS No. F-00881
Section 1.  Product  Identification                                                                                                   
 Product :
 AR-400NT / AR-400ST / AR-400T (Black Toner)  
For use with: AR-250, AR-286, AR-287, AR-336, AR-337, AR-405, AR-407
Section 2.  Supplier's  Name  and  Address                                                                                   
 Sharp Corporation
 22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
 Local suppliers are listed below.  Please contact the nearest supplier for additional information.
(Country)
(Name  and  Telephone  Number)
U.S.A.
Sharp Electronics Corporation
Telephone number for information : 1-800-237-4277
Emergency telephone number : 1-800-255-3924
Canada
Sharp Electronics of Canada Ltd.
Telephone number for information : 905-890-2100
Emergency telephone number : 1-800-255-3924
United
Kingdom
Sharp Electronics (U.K.) Ltd.
Telephone number for information : 01923 474013
                                                                                                                                                                                      
Section 3.  Ingredients                                                                                                                      
       Ingredients
CAS No.
Proportion
OSHA PEL
ACGIH TLV
Other Limits
Graft polymer(polyester,Styrene-Acrylate)14367-99-7 <55%
Not listed
Not listed
None
Polyester resin 1
NJ TSRN 80100252-5009P
<20%
Not listed
Not listed
None
Polyester resin 2
116736-81-3
<20%
Not listed
Not listed
None
Carbon black
1333-86-4
 <4%
3.5mg/m
3
3.5mg/m
3
None
Wax 1
9010-79-1
<2%
Not listed
Not listed
None
Wax 2
8015-86-9
<2%
Not listed
Not listed
None
Pigment
31714-55-3
<1%
Not listed
Not listed
None
Silica
68909-20-6
<1%
15mg/m
3
10mg/m
3
None
                                                                                                                                                                                      
Section 4.  Hazardous  Identification  (Emergency  Overview)
                                                              
 Toner is a fine, black powder possessing no immediate hazard. There are no anticipated carcinogenic effects from
exposure based on animal tests performed using toner. When used as intended according to instructions, studies do
not indicate any symptoms of fibrosis will occur.
                                                                                                                                                                                      
Section 5.  Health  Hazard  Data                                                                                                      
 Route(s) of Entry  :  Inhalation?
Skin?
Ingestion?
 
    Yes
 
   No
Possible but very unusual.
 Health Hazards   :
Acute oral toxicity --- LD50 >5,000mg/kg LC50 >6.42mg/L / 4Hrs.
Mutagenicity (Ames test) --- Negative (S.typhimurium, Escherichia coli).
(These are toxicity data of similar material.)
 Carcinogenicity   :
In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human
carcinogen).  This classification is given to chemicals for which there is  inadequate human
evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity.  The
classification is based upon the development of lung tumors in rats receiving chronic
inhalation exposures to free carbon black at levels that induce particle overload of the lung.
Studies performed in animal models other than rats did  not show any association between
carbon black and lung tumors.  Moreover, a two-year cancer bioassay using a typical toner
preparation containing carbon black demonstrated no association between toner exposure
and tumor development in rats.
 Chronic Effect    :
In a study in rats of chronic inhalation exposure to a typical toner, a mild to moderate degree
of lung fibrosis was observed in 92% of the rats in the high concentration (16mg/m
3
)
exposure group, and a minimal to mild degree of fibrosis was noted in 22% of the animals in
the middle (4mg/m
3
) exposure group, but no pulmonary change was reported in the lowest
(1mg/m
3
) exposure group, the most relevant level to potential human exposures.
 Signs and Symptoms of Exposure
   :
Minimal irritation to respiratory tract may occur as with
exposure to any non-toxic dust.
 Medical Conditions Generally Aggravated by Exposure :  None
S  H  A  R  P
    Data Revised :
    Date Issued  : Dec.  1, 1998
MATERIAL  SAFETY  DATA  SHEET  (2/2)
                                                                                                                                                       MSDS No. F-00881
Section 5.  Health  Hazard  Data (Continued)                                                                                 
 Emergency and First Aid Procedures   :
Inhalation  ; Remove to fresh air.  If effects occur, consult medical personnel.
Eye
    ; In case of contact, immediately flush eyes with water for 15 minutes.
                                                                                                                                                                                      
Section 6.  Physical  Chemical  Characteristics
                                                                                         
 Boiling / Melting Point
: Not applicable
Specific Gravity
: 1.2
 Vapor Pressure
: Not applicable
Solubility in Water
: Negligible
 Vapor Density
: Not applicable
PH
: Not applicable
 Evaporation Rate
: Not applicable
Viscosity
: Not applicable
 Appearance
: Fine powder
Color
: Black
 Odor
: Odorless
                                                                                                                                                                                      
Section 7.  Fire  and  Explosion  Data                                                                                             
 Flash Point (Method Used)
:
Not applicable
 Ignition Temperature
:
Not applicable
 Flammable Limits
:
(LEL); Not known
(UEL); Not known
 Extinguishing Media
:
CO2, dry chemical, foam or water
 Special Fire Fighting Procedure
:
None
 Unusual Fire and Explosion Hazard
:
This material has no unusual fire or explosion hazards.
 Sensitivity to Mechanical Impact
:
None
 Sensitivity to Static Charge
:
None
                                                                                                                                                                                      
Section 8.  Reactivity  Data                                                                                                              
 Stability
:
Stable
 Incompatibility (Material to Avoid)
:
Strong acid or alkaline
 Hazardous Decomposition
:
Phenol derivatives, Carbon monoxide when heated at high
temperature.(>300
0
C)
 Hazardous Polymerization
:
Will not occur.
                                                                                                                                                                                      
Section 9.  Precautions  for  Safe  Handling  and  Use                                                                  
 Personal Protection Information (Respiratory, Eye Protection and Protective Glove):
Use of a dust mask is recommended when handling a large quantity
of toner or during long term exposure, as with any non-toxic dust.
 Engineering Control / Ventilation
:
Not required.
 Work / Hygienic Practice
:
Inhalation should be minimized as with any non-toxic dust.
 Steps to be taken in case of Spill or Leak :
Sweep up or clean up with vacuum cleaner.
 Waste Disposal Method
:
Waste material may be dumped or incinerated under conditions
              
which meet all federal, state and local environmental regulations.
                                                                                                                                                                                      
Section 10.  Regulatory  Information                                                                                               
 NFPA Rating (U.S.A.)
:
Health = 1
Flammability = 1
Reactivity = 0
 WHMIS Legislation (Canada)
:
This product is not a controlled product.
 Transport Information
:
This product is not a hazardous material.
 UN No.
:
None allocated.
                                                                                                                                                                                      
Section 11.  Other  Information                                                                                                        
 References  :
IARC (1996) IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to
    Humans, Vol. 65, Printing Process and Printing inks, Carbon Black and Some Nitro Compounds, Lyon, pp-149-261
    H. Muhle, B. Bellmann, O. Creutzenberg, C. Dasenbrock, H. Ernst, R. Kilpper, J. C. MacKenzie,
    P. Morrow, U. Mohr, S. Takenaka, and R. Mermelstein (1991) Pulmonary Response to Toner upon Chronic
    Inhalation Exposure in Rats.  Fundamental and Applied Toxicology 17, pp. 280-299
                                                                                                                                                                                      
Display

Sharp AR-407 (serv.man86) Regulatory Data ▷ Download

  • DOWNLOAD Sharp AR-407 (serv.man86) Service Manual ↓ Size: 12.84 KB | Pages: 2 in PDF or view online for FREE
  • Here you can View online or download the Regulatory Data for the Sharp AR-407 (serv.man86) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-407 (serv.man86) Copying Equipment. Information contained in Sharp AR-407 (serv.man86) Regulatory Data (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.