Sharp AR-405 (serv.man9) Service Manual ▷ View online

*
Note for assembling the copy lamp unit
Move the copy lamp unit to the paper exit side, and fix the copy lamp
unit wiht the harness guide so that the distance between the copy
lamp harness and the lower frame is about 25 ~ 30 mm with the copy
lamp harness extended.
Shift the copy lamp unit to the paper exit side, and fix it with the
harness guide so that the distance from the lower frame is about 24 
±
2mm with the copy lamp harness extended. 
After fixing, manually shift the copy lamp unit a few times to check
that it moves smoothly. 
If the copy lamp harness is loosely fixed, the copy lamp unit may
jump up when reading, resulting in abnormal reading. 
AR-2XX/3XX series
AR-405
(2) Vertical image distortion balance adjustment
(No. 2/3 mirror base unit installing position
adjustment)
This adjustment is to adjust the parallelism of the mirror base to the
OPC drum surface and the original surface. 
1) Manually turn the mirror base drive pulley to bring mirror base B
into contact with mirror base positioning plate. 
If, at that time, the front frame side and the frame side of mirror
base B are brought into contact with the mirror base positioning
plate simultaneously, the parallelism is correct and there is no
need for adjustment. 
(3) Sub scanning direction distortion adjustment
(Winding pulley position adjustment)
This adjustment is executed in the following cases:
When the mirror base drive wire is replaced.
When the lamp unit, or No. 2/3 mirror holder is replaced.
When a copy shown below is made.
24±2mm
25±30mm
Lb
La
Original
Paper exit
direction
Copy
AR-405
1/21/1999
7 – 8
9) Remove the slide pin of the front cover unit. 
10) Insert the slid pin as shown below and make positioning in the
vertical direction. 
11) Insert the slide pin as shown below and make positioning in the
horizontal direction.
(Initial position positioning is completed.)
*
Never loosen the screws which are not indicated in the figure.
If loosened, the adjustment cannot be made and the unit must be
replaced. 
12) Make a sample copy in the initial position and measure the
magnification ration again. 
13) Change the installing position in the horizontal direction to adjust
the magnification ratio.
When the copy image is longer than the original, move in
the direction of B.
When the copy image is shorter than the original, move in
the direction of A.
One scale of scribe line corresponds to 0.2%.
For fine errors which cannot be adjusted with this
adjustment, use the next simulation SIM 48-1.
Never loosen a screw other than these ones.
A
B
AR-335
7 – 11
1/21/1999
(6) Main/sub scanning direction magnification ratio
adjustment
1) Before this adjustment, perform the previous adjustment of CCD
unit installation position.
2) Place a scale on the original table as shown. (Scale a and scale b
may be placed together or individually.)
After warming up, the ready lamp lights up.
The current set value is displayed simultaneously. (0 
 20)
3) Make a normal copy and obtain the main/sub scanning direction
magnification ratios.
Copy magnification ratio (MRCP)
 = 
(
Original dimension – Copy dimension
)
Original dimension
 
×
 100%
4) Execute SIM 48-1.
5) Change value A so that the magnification ratio in the sub scanning
direction is within the specified range.
6) Change value B so that the magnification ratio in the main scan-
ning direction is within the specified range.
Adjustment specification: Within 
±
0.8%
When the copy dimension is smaller than the original
Make the value greater.
When the copy dimension is greater than the original
Make the value smaller.
When the value is changed by one step, the ratio is changed
by about 0.1%.
[AR-280 only]
7) Make a copy of A3 original with SPF, and measure the magnifica-
tion ratio in the sub scanning direction.
8) Change value C so that the magnification ratio in the sub scan-
ning direction is within the specified range.
9) Press the CA key to cancel the simulation.
(7) Copy image position, image loss, void area
adjustment
Before performing this adjustment, check that SIM 50-5 is set to 50. If
not, set it to 50.
This adjustment uses SIM 50-2 and SIM 50-1.
The above two simulations are used in the following manner.
Sim 50-2:
Rough adjustment
SIM 50-1:
Fine adjustment
If the desired value is obtained by SIM 50-2, there is no need to
perform SIM 50-1.
10
20
30
40
50
60
70
80
90
50
10
0
110
120
130
140
10
20
30 40 50 60 70
80 90
50 100 110 120 130 140
Scale a
Scale b
10
20
90
100
110
10
20
90
100
110
10
20
90
100
110
Scale
(Original)
(Example 1)
Copy A
(Shorter than
the original)
(Example 2)
Copy B
(Longer than
the original)
Paper exit direction
a    > Magnification ration in the main scanning direction
b    > Magnification ratio in the sub scanning direction
AR-405
1/21/1999
7 – 12
(Adjustment items)
No.
Adjustment item
Operation mode
SIM 50-2 set
item
SIM 50-1 set
item
Adjustment
value
Note
1
Lead edge image loss
Document
table mode
SPF mode
IMAGE LOSS
IMAGE LOSS
1.5 to 3.0 mm
2
Lead edge void area
Document
table mode
SPF mode
DEN-A
DEN-A
1.5 to 3.0 mm
3
Rear edge image loss
SPF mode
REAR LOSS
(SPF)
REAR LOSS
(SPF)
1.5 to 3.0 mm
AR-4XX
series only
4
Rear edge void area
Document
table mode
SPF mode
DEN-B
DEN-B
5
Image reference position
Document
table mode
RRC-A
6
Paper timing
Document
table mode
SPF mode
RRC-B
7
Image reference position
SPF mode
SPF
8
Distance between image lead edge
position and scale of 10mm 
×
 10
Document
table mode
L1
9
Distance between paper lead edge
and image lead edge 
×
 10
Document
table mode
L2
10
Distance between image lead edge
position x scale of 10mm 
×
 10
SPF mode
L3
Adjustment items 1  
  4 can be adjusted either with SIM 50-1 or SIM 50-2.
The adjustment values of items 8  
  10 will affect the adjustment items 5  
  7 automatically.
Therefore, adjusting the items 8  
  10 will lead to the same result as adjusting the items 5  
  7.
  1) Place a scale on the document table as shown below, and  make
a normal (100%) copy.
Note that the scale must be place in parallel to the scanning
direction and that the scale lead edge must be clearly copied.
  2) Process the copied paper as shown below.
Cut the copied paper along the line at the edge of the scale
image. The cut line and the scale image must form a right angle
(90 degrees).
  3) Place the scale on the document table as shown below.
Note that the scale must be place in parallel to the scanning
direction and that the scale lead edge is in close contact with the
document guide plate.
  4) Enter the SIM 50-2 mode.
  5) Set the image loss and DEN-A set values to "0."
  6) Set all the values of L1, L2, and L3 to "0."
  7) Make a copy at 400%. (Document table mode)
Scale
100
110
120
130
150
140
10
20
90
30
80
70
60
50
40
Scale lead edge
Paper
Cut the paper along this line.
10
20
30 40 50 60 70
80 90
50 100 110 120 130 140
Scale
Paper (White paper)
AR-405
7 – 13
1/21/1999
Page of 18
Display