Sharp AR-335 Handy Guide ▷ View online
TECHNICAL UPDATE
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
49
VERSION 1C
MARCH 2002
PERIPHERALS
Model
Fault
Advice
AR-FN1
Paper jams at FPID
Paper catches when using the short
path. Adjust the position of the short
patch gate solenoid. Make sure the
springs have been removed from the
exit door when installing a finisher (not
AR505.507).
path. Adjust the position of the short
patch gate solenoid. Make sure the
springs have been removed from the
exit door when installing a finisher (not
AR505.507).
AR-FN1/3
FPFD3 & FPFD4 jams when using
staple mode.
staple mode.
Incorrect pressure of transport rollers
on transport door. Relocate rollers
and check if roller shaft is binding with
the location guides.
on transport door. Relocate rollers
and check if roller shaft is binding with
the location guides.
AR-FN1/3
FT30D_N paper jams.
Damaged delivery gate 3 – replace
(0EUGID0426L// - PG10-20).
(0EUGID0426L// - PG10-20).
AR-FN1/3
FSTIDS paper jams
Actuator not fully engaging with the
detector. Remove actuator and add 1
turn to the return spring.
detector. Remove actuator and add 1
turn to the return spring.
AR-FN1/3
FPFD2 jam – unable to reset.
The top cover of the FN1/3 has been
bent causing the PFD2 sensor to foul
the ribs on the cover – replace.
bent causing the PFD2 sensor to foul
the ribs on the cover – replace.
AR-FN1/3
FPFRD3/4 misfeeds.
Check and/or replace the finisher curl
correction rollers. (Life 250k).
correction rollers. (Life 250k).
AR-FN1/3
“Remove Paper from Tray2” error at
power on.
power on.
T2PF sensor actuator jammed/broken
or missing – replace.
or missing – replace.
AR-FN1
A3 jamming when face down printing.
Incorrect firmware – upgrade to v2.13
or higher.
or higher.
AR-FN1/3
When using staple mode, the capacity
of the off-set tray is reduced.
of the off-set tray is reduced.
Due to the increased thickness of the
stack when stapling, the software
automatically reduces the stack height
depending on the number of sets.
stack when stapling, the software
automatically reduces the stack height
depending on the number of sets.
AR-FN1/3
F1-08
See error code section.
AR-FN2
F1-05, F1-11, F1-14 & F1-15
See error code section.
AR-FN2
BES_S jams.
Check the position of the BES sensor.
If the operator pulls the compiled
bundle before the job is complete, this
will cause a BES jam.
If the operator pulls the compiled
bundle before the job is complete, this
will cause a BES jam.
AR-FN2
Jamming at FJTES.
Incorrect operation of the PRSL
reverse solenoid.
Check for a damaged flapper arm or
the incorrect fitting of the cushion
(adhesive showing).
reverse solenoid.
Check for a damaged flapper arm or
the incorrect fitting of the cushion
(adhesive showing).
AR-FN2
Jamming when printing A3 “Face
Down”.
Down”.
Incorrect firmware – upgrade to v1.03
or higher.
or higher.
AR-FN2
Jamming at entry.
Check and/or replace curl correction
roller. Also check for installed
pressure springs on exit door.
roller. Also check for installed
pressure springs on exit door.
TECHNICAL UPDATE
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
50
VERSION 1C
MARCH 2002
PERIPHERALS
Model
Fault
Advice
AR-FN2
“Check finisher cover” message.
Incorrect fitting of locating pin or poor
finisher alignment. Adjust finisher
height. (also check ULS2 operation).
finisher alignment. Adjust finisher
height. (also check ULS2 operation).
AR-FN2
Corruption of image data or “Bar
Coded” copies.
Coded” copies.
Check AR-FN2 for static electricity
interfering with 5/24v.
Fit modified earth plates :- PG9/17
interfering with 5/24v.
Fit modified earth plates :- PG9/17
0CW4090P060//
and PG10/55
0CW4090P061//
(fitted as standard
from March’99).
AR-LC1
LCC locked out – enable to open.
Reset with Sim 15.
IC-22
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
51
VERSION 1C
MARCH 2002
IC22 Re Initialise Procedure
Detailed below is a procedure on how to reset machine data due to IC22 replacement or
failure (corruption). Refer to the “Parts Compatibility” section for IC22 machine compatibility.
Where possible, execute Simulation 22-06 (Data Print) for meter reading and machine
set-up information etc prior to re-initialising.
failure (corruption). Refer to the “Parts Compatibility” section for IC22 machine compatibility.
Where possible, execute Simulation 22-06 (Data Print) for meter reading and machine
set-up information etc prior to re-initialising.
NOTE:
For AR287/337/407 and 507 models with an AR-NS1 installed, a
replacement IC22 must be obtained via the EEprom exchange service
from TPM Group.
replacement IC22 must be obtained via the EEprom exchange service
from TPM Group.
The AR-NS1 cannot be reactivated following the execution of this
procedure as the Product Key is linked to the machine serial number,
which is erased.
procedure as the Product Key is linked to the machine serial number,
which is erased.
Procedure:
1.
Remove IC22 and Power On the Copier - A U2 Trouble Code should be
displayed.
displayed.
2. Enter
Simulation 80-09 (Initial Data Setting) but DO NOT execute.
3.
Carefully Insert IC22 (with the copier still powered on).
4. Now
Execute
Simulation 80-09 to reprogram the EEProm with the Initial
Data.
5.
Power cycle the copier & Execute Simulation 16 to clear “U2” trouble.
6. Execute
Simulations 89-01 and 89-02 to clear all counters and key
operator data. Also use Simulation 24-01 to clear trouble/jam history
counters.
counters.
7. Execute
Enter
Simulation 26-59 (Scan Motor Set-up) to correct L3-00
trouble code - Set either “2 or 3” for 2 or 3 phase motor respectively.
AR287, 337, 407 or 507 models only
AR287, 337, 407 or 507 models only
8.
Re-enter the Toner Density Value by using Simulation 80-02 or
Simulation 25-02 (recycling the developer).
Simulation 25-02 (recycling the developer).
9.
Re configure the SCSI port set-up using Simulation 26-44.
10. Change
Simulation 26-06 to “UK Destination” and check “UK English”
language set-up within Simulation 26-22.
Cont’d
IC-22
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
52
VERSION 1C
MARCH 2002
11.
Adjust all RADF sensors using Simulation 53-02.
Once the above settings have all been input, check the following Test
Simulation settings by comparing the Data Sheets:-
Simulation settings by comparing the Data Sheets:-
Simulation 8-01 & 8-02
DV & HV output settings.
Simulation 26-35
Error trouble count.
Simulation
46 Exposure
settings.
Simulation 50
Lead edge and void settings.
Simulation 51
Resist roller buckle.
Cougar Total Counter Setting
Re-enter the following machine meter readings from the engine data print:-
Total
Counter Simulation
81
Maintenance
Counter
Simulation
82
“Copies”
Counter
Simulation
83-06
“Printer”
Counter
Simulation
83-10
“Others”
Counter
Simulation
83-12
“Scan” Counter
Simulation 83-13
Developer Counter
Simulation 85
Note:
For Non Cougar 2000 models (eg AR335), the “Copy” counter reading that is
obtained by the customer (by holding down the Copy button on the operation
display) can only be re-entered in “Hex Value” by using Test Simulation 79.
obtained by the customer (by holding down the Copy button on the operation
display) can only be re-entered in “Hex Value” by using Test Simulation 79.
Example 1:-
If the count is 1,500 , the Hex value of “5DC” is to be entered within the addresses
0052 ~ 0055 as follows:–
0052 ~ 0055 as follows:–
Input 00
in address 0052
Input 00
in address 0053
Input 05
in address 0054
Input DC
in address 0055
Cont’d
Click on the first or last page to see other AR-335 service manuals if exist.