DOWNLOAD Sharp AR-285 Service Manual ↓ Size: 218.68 KB | Pages: 54 in PDF or view online for FREE

Model
AR-285
Pages
54
Size
218.68 KB
Type
PDF
Document
Handy Guide
Brand
Device
Copying Equipment / Cougar Handy Guide (Updated March'02)
File
ar-285.pdf
Date

Sharp AR-285 Handy Guide ▷ View online

 
MACHINE INSTALLATION 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
VERSION 1C 
MARCH 2002
 
 
 
 
CUSTOM SETTINGS (Key 
Operator) 
 
 
 
Auto Power Off Setting 
Pre-Heat Timer Setting 
Auto Exposure Setting 
Date & Time Setting 
 
 
 
 
 
 
SIMULATION DATA PRINT 
 
 
Sim 22 – 06 
Print All Simulation Data
 
 
 
 
 
 
 
MAINTENANCE 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
10 
VERSION 1C 
MARCH 2002
 
 
 
Maintenance Schedule 
 
AR250 – AR337 
AR405 – AR407 
AR-505 - 507 
Interval 
Req’d 
Interval 
Req’d 
Interval 
Req’d 
 
 
 
 
 
 
80k 
AR330KA 
90k 
AR400KA 
125k 
AR505KA 
240k 
AR336DV 
270k 
AR400DV 
375k 
AR505FL 
400k 
560k 
AR330FL 
450k 
630k 
AR330FL 
625k 
875k 
 
 
 
 
 
 
 
 
 
 
 
 
 
160k 
AR330KA 
180k 
AR400KA 
250k 
AR505KA 
320k 
AR337KB 
360k 
AR407KB 
500k 
AR505KB 
480k 
AR336DV 
540k 
AR400DV 
750k 
AR500DV 
640k 
AR336DM 
 
AR400DM 
1000k 
AR500DM 
 
AR330FL 
 
AR330FL 
 
AR505FL 
 
 
 
 
MACHINE DATA PRINT 
 
 
Sim 22 – 06 
Print All Simulation Data
 
 
 
 
 
 
 
 
MAINTENANCE  
COMPLETED 
 
Sim 24 – 04 
Maintenance Counter Reset 
Sim 21 – 01 
Maintenance Setting Check 
 
 
 
 
 
 
DEVELOPER  
REPLACEMENT 
 
 
Sim 24 – 05 
Developer Counter Reset
 
Sim 24 – 11 
Developer Rotation Time  
  Reset
  
Sim 25 – 01 
DV Stir (Twice)
 
Sim 25 – 02 
DV Level Setting
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cont’d 
 
 
MAINTENANCE 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
11 
VERSION 1C 
MARCH 2002
 
 
 
 
DRUM  REPLACEMENT 
 
 
Sim 24 – 07 
Drum Membrane Counter 
  Reset 
 
 
 
 
 
 
PROCESS  CONTROL 
 
 
Sim 44 – 02 
ID & DM Sensor Adjust  
  (< 
100) 
 
 
 
 
 
 
COPY  QUALITY 
 
 
P 20   
Auto Exposure  
  (Custom 
Setting) 
Sim 46 – 02 
Copier Mode Adjust 
 
 
 
 
 
 
JAM  &  TROUBLE  COUNTER 
 
 
Sim  24 – 01 
Jam/Trouble Counter 
Reset 
 
 
 
 
 
 
FEED  ROLLER  REPLACEMENT 
 
 
Sim 24 – 02 
Individual Tray  
  Counter 
Reset 
 
 
 
 
 
 
MACHINE DATA PRINT 
 
Sim.22-06
 
Simulation Data Print 
 
 
 
 
 
MACHINE ADJUSTMENTS 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
12 
VERSION 1C 
MARCH 2002
 
 
 
Section 
Adjustment Item 
Adjustment 
 Procedure 
Process 
 
 
1  Developer doctor gap 
 
2  MG roller main pole position 
 
3  Dev bias voltage 
Sim 8-1  / 44-15 
4  Main charger grid voltage 
Sim 8-2  / 44-15 
5  Transfer charge voltage 
Sim 8-6 
6  Separation bias voltage 
Sim 8-7 
7  Drum marking sensor 
Sim 44-2 
  Image density sensor 
Sim 44-2 
8  Toner concentration 
Sim 25-2 
Laser scanner 
 
 
1  Horizontal image distortion 
LSU lever adjustment 
2  Print off center 
Sim 50-10 
3  Laser power setting 
Sim 61-20 / 44-15 
Scanner 
 
 
1  Vertical image distortion balance 
Copy lamp unit installing position 
2  Vertical image distortion balance 
No2/3 mirror base installing position 
3  Vertical image distortion 
Winding pulley position 
4  Horizontal image distortion  
F rail height adjust 
5  Main scan magnification ratio  
CCD unit position 
6  Main scan magnification ratio 
Sim 48-1 
7  Shading plate correction 
Sim 46-17 
8  Scanning image position 
Sim 50-2 
9  Original off center 
Sim 50-12 
Copy Density 
 
 
1  Copy mode 
Sim 46  
Paper Feed 
 
 
1  Manual bypass detection level 
Sim 40-2 
2  Paper size setting 
 
Paper Trans        1    Separation Pawl Timing 
Sim 51-1 
2  Resist Roller Buckle 
Sim 51-2 
Others 
 
 
1  Original size sensor detection 
level 
Sim 41-1 / 41-2 
2  Waste toner full detection 
 
3  Touch panel 
Sim 65-1 
4  Key touch sound volume 
Sound volume adjustment 
SPF 
 
 
1  Hinge height 
Table clearance 
2  Open/Close sensor position 
Sim 2-2 
ADF 
 
 
1  Lead edge stop position 
Sim 53-1 
2  ADF sensor level adjustment 
Sim 53-2 
3  Test Mode with Dip switch 
 
Page of 54
Display