DOWNLOAD Sharp AR-285 Service Manual ↓ Size: 218.68 KB | Pages: 54 in PDF or view online for FREE

Model
AR-285
Pages
54
Size
218.68 KB
Type
PDF
Document
Handy Guide
Brand
Device
Copying Equipment / Cougar Handy Guide (Updated March'02)
File
ar-285.pdf
Date

Sharp AR-285 Handy Guide ▷ View online

 
IC-22  
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
51 
VERSION 1C 
MARCH 2002
 
 
 
IC22 Re Initialise Procedure 
 
Detailed below is a procedure on how to reset machine data due to IC22 replacement or 
failure (corruption). Refer to the “Parts Compatibility” section for IC22 machine compatibility. 
 
Where possible, execute Simulation 22-06 (Data Print) for meter reading and machine  
set-up information etc prior to re-initialising. 
 
NOTE: 
For AR287/337/407 and 507 models with an AR-NS1 installed, a 
replacement IC22 must be obtained via the EEprom exchange service  
from TPM Group.  
 
The AR-NS1 cannot be reactivated following the execution of this 
procedure as the Product Key is linked to the machine serial number, 
which is erased. 
 
 
 Procedure: 
1. 
Remove IC22 and Power On the Copier - A U2 Trouble Code should be 
displayed. 
 
2. Enter 
Simulation 80-09  (Initial Data Setting) but DO NOT execute. 
 
3. 
Carefully Insert IC22 (with the copier still powered on). 
 
4. Now 
Execute 
Simulation 80-09 to reprogram the EEProm with the Initial 
Data. 
 
5. 
Power cycle the copier & Execute Simulation 16 to clear “U2” trouble. 
 
6. Execute 
Simulations 89-01 and 89-02 to clear all counters and key 
operator data. Also use Simulation 24-01 to clear trouble/jam history 
counters. 
 
7. Execute 
Enter 
Simulation 26-59 (Scan Motor Set-up) to correct L3-00 
trouble code - Set either “2 or 3” for 2 or 3 phase motor respectively. 
AR287, 337, 407 or 507 models only 
 
8. 
Re-enter the Toner Density Value by using Simulation 80-02 or  
Simulation 25-02 (recycling the developer). 
 
9. 
Re configure the SCSI port set-up using Simulation 26-44. 
 
10. Change 
Simulation 26-06 to “UK Destination” and check “UK English” 
language set-up within Simulation 26-22
 
 
 
 
 
 
 
 
 
 
Cont’d 
 
IC-22  
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
52 
VERSION 1C 
MARCH 2002
 
 
 
11. 
Adjust all RADF sensors using Simulation 53-02. 
 
Once the above settings have all been input, check the following Test  
Simulation settings by comparing the Data Sheets:- 
 
 
Simulation 8-01 & 8-02 
DV & HV output settings. 
 
Simulation 26-35 
 
Error trouble count. 
 Simulation 
46  Exposure 
settings. 
 
Simulation 50 
 
Lead edge and void settings. 
 
Simulation 51 
 
Resist roller buckle. 
 
 
 
Cougar Total Counter Setting 
 
 
Re-enter the following machine meter readings from the engine data print:- 
 
    Total 
Counter  Simulation 
81 
    Maintenance 
Counter 
Simulation 
82 
    “Copies” 
Counter 
 Simulation 
83-06 
    “Printer” 
Counter 
 Simulation 
83-10 
    “Others” 
Counter 
 Simulation 
83-12 
“Scan” Counter 
 
Simulation 83-13 
Developer Counter   
Simulation 85 
 
 
Note: 
For Non Cougar 2000 models (eg AR335), the “Copy” counter reading that is  
obtained by the customer (by holding down the Copy button on the operation  
display) can only be re-entered in “Hex Value” by using Test Simulation 79.  
 
 
Example 1:- 
 
If the count is 1,500 , the Hex value of “5DC” is to be entered within the addresses 
0052 ~ 0055 as follows:– 
 
Input 00  
in address 0052 
Input 00  
in address 0053 
Input 05  
in address 0054 
Input DC 
in address 0055 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cont’d 
 
IC-22  
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
53 
VERSION 1C 
MARCH 2002
 
 
 
Example 2:- 
 
If the Hex value A29F4 (Count 666,100) enter as follows:-, 
 
Input 00  
in address 0052 
Input 0A  
in address 0053 
Input 29  
in address 0054 
Input F4  
in address 0055 
 
Repeat the same input in all the following addresses:- 
 
1. 
Input the addresses 0052 ~ 0055  
(as already stated) 
2. 
Input the addresses 0092 ~ 0095  
in the same way as 1 
3. 
Input the addresses 00D2  ~ 00D5  
in the same way as 1 
4. 
Input the addresses 0112  ~ 0115 
in the same way as 1 
5. 
Input the addresses 0152  ~ 0155 
in the same way as 1 
6. 
Input the addresses 0192  ~ 0195 
in the same way as 1 
7. 
Input the addresses 01D2  ~ 01D5 
in the same way as 1 
8. 
Input the addresses  0212  ~ 0215 
in the same way as 1 
 
 
 
 
NOTES 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
54 
VERSION 1C 
MARCH 2002
 
 
 
 
 
 
 
 
 
 
 
 
Page of 54