IC22 Re Initialise Procedure
Detailed below is a procedure on how to reset machine data due to IC22 replacement or
failure (corruption). Refer to the “Parts Compatibility” section for IC22 machine compatibility.
Where possible, execute Simulation 22-06 (Data Print) for meter reading and machine
set-up information etc prior to re-initialising.
failure (corruption). Refer to the “Parts Compatibility” section for IC22 machine compatibility.
Where possible, execute Simulation 22-06 (Data Print) for meter reading and machine
set-up information etc prior to re-initialising.
NOTE:
For AR287/337/407 and 507 models with an AR-NS1 installed, a
replacement IC22 must be obtained via the EEprom exchange service
from TPM Group.
replacement IC22 must be obtained via the EEprom exchange service
from TPM Group.
The AR-NS1 cannot be reactivated following the execution of this
procedure as the Product Key is linked to the machine serial number,
which is erased.
procedure as the Product Key is linked to the machine serial number,
which is erased.
Procedure:
1.
Remove IC22 and Power On the Copier - A U2 Trouble Code should be
displayed.
displayed.
2. Enter
Simulation 80-09 (Initial Data Setting) but DO NOT execute.
3.
Carefully Insert IC22 (with the copier still powered on).
4. Now
Execute
Simulation 80-09 to reprogram the EEProm with the Initial
Data.
5.
Power cycle the copier & Execute Simulation 16 to clear “U2” trouble.
6. Execute
Simulations 89-01 and 89-02 to clear all counters and key
operator data. Also use Simulation 24-01 to clear trouble/jam history
counters.
counters.
7. Execute
Enter
Simulation 26-59 (Scan Motor Set-up) to correct L3-00
trouble code - Set either “2 or 3” for 2 or 3 phase motor respectively.
AR287, 337, 407 or 507 models only
AR287, 337, 407 or 507 models only
8.
Re-enter the Toner Density Value by using Simulation 80-02 or
Simulation 25-02 (recycling the developer).
Simulation 25-02 (recycling the developer).
9.
Re configure the SCSI port set-up using Simulation 26-44.
10. Change
Simulation 26-06 to “UK Destination” and check “UK English”
language set-up within Simulation 26-22.
Cont’d
IC-22
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
52
VERSION 1C
MARCH 2002
11.
Adjust all RADF sensors using Simulation 53-02.
Once the above settings have all been input, check the following Test
Simulation settings by comparing the Data Sheets:-
Simulation settings by comparing the Data Sheets:-
Simulation 8-01 & 8-02
DV & HV output settings.
Simulation 26-35
Error trouble count.
Simulation
46 Exposure
settings.
Simulation 50
Lead edge and void settings.
Simulation 51
Resist roller buckle.
Cougar Total Counter Setting
Re-enter the following machine meter readings from the engine data print:-
Total
Counter Simulation
81
Maintenance
Counter
Simulation
82
“Copies”
Counter
Simulation
83-06
“Printer”
Counter
Simulation
83-10
“Others”
Counter
Simulation
83-12
“Scan” Counter
Simulation 83-13
Developer Counter
Simulation 85
Note:
For Non Cougar 2000 models (eg AR335), the “Copy” counter reading that is
obtained by the customer (by holding down the Copy button on the operation
display) can only be re-entered in “Hex Value” by using Test Simulation 79.
obtained by the customer (by holding down the Copy button on the operation
display) can only be re-entered in “Hex Value” by using Test Simulation 79.
Example 1:-
If the count is 1,500 , the Hex value of “5DC” is to be entered within the addresses
0052 ~ 0055 as follows:–
0052 ~ 0055 as follows:–
Input 00
in address 0052
Input 00
in address 0053
Input 05
in address 0054
Input DC
in address 0055
Cont’d
IC-22
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
53
VERSION 1C
MARCH 2002
Example 2:-
If the Hex value A29F4 (Count 666,100) enter as follows:-,
Input 00
in address 0052
Input 0A
in address 0053
Input 29
in address 0054
Input F4
in address 0055
Repeat the same input in all the following addresses:-
1.
Input the addresses 0052 ~ 0055
(as already stated)
2.
Input the addresses 0092 ~ 0095
in the same way as 1
3.
Input the addresses 00D2 ~ 00D5
in the same way as 1
4.
Input the addresses 0112 ~ 0115
in the same way as 1
5.
Input the addresses 0152 ~ 0155
in the same way as 1
6.
Input the addresses 0192 ~ 0195
in the same way as 1
7.
Input the addresses 01D2 ~ 01D5
in the same way as 1
8.
Input the addresses 0212 ~ 0215
in the same way as 1