DOWNLOAD Sharp AR-285 (serv.man16) Service Manual ↓ Size: 59.52 KB | Pages: 6 in PDF or view online for FREE

Model
AR-285 (serv.man16)
Pages
6
Size
59.52 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR280 285 335 Service Manual-Operational Description
File
ar-285-sm16.pdf
Date

Sharp AR-285 (serv.man16) Service Manual ▷ View online

(6) Main charger grid voltage correction 2
a. Outline and purpose
When the developing bias voltage is changed, the main charger grid voltage correction 2 is performed to maintain the relation between the
developing bias voltage and the main charger grid voltage at constant. 
b. Details
After the developing bias voltage correction, the voltage of correction of the developing bias voltage is automatically added to the main charger grid
voltage.
Actual main charger grid voltage variable range: –200 to –900V
(7) Laser beam power correction 2
To maintain the OPC drum bright potential at constant for changes in the main charger grid voltage due to main charger grid voltage correction 1
and 2, the laser beam power must be changed accordingly. 
Laser beam power correction 2 is performed to output the laser beam power according to the above situation. 
This correction provides stable print density. 
(8) Toner concentration correction 
a. Outline and purpose
This correction is used to correct changes in the developer characteristics due to aging and change in the environmental conditions. 
When any change occurs in the developer characteristics, it causes under-toner or over-toner, resulting in improper print density. 
To prevent against this, the reference toner control level is changed according to the conditions to maintain the specified toner concentration. 
This correction provides stable print density.
b. Details of operation 
When the developing bias correction voltage (  Vdbc(n)) is minus-corrected (shifted to the positive polarity direction), it is recognized as an
increase in developing capability, and the reference toner concentration control level set with SIM 25-2 is increased. 
With the above operation, toner concentration is decreased to maintain the proper print density. 
The correction data is cleared to "0" when SIM 25-2 is executed.
TONER CONCENTRATION CORRECTION
1
99
T(time)
MAX 20
5
Operated process(DV bias correction) correction
Toner concentration
control level
Original reference toner
concentration control 
level(Set by SIM25-2)
12 – 4
(6) Main charger grid voltage correction 2
a. Outline and purpose
When the developing bias voltage is changed, the main charger grid voltage correction 2 is performed to maintain the relation between the
developing bias voltage and the main charger grid voltage at constant. 
b. Details
After the developing bias voltage correction, the voltage of correction of the developing bias voltage is automatically added to the main charger grid
voltage.
Actual main charger grid voltage variable range: –200 to –900V
(7) Laser beam power correction 2
To maintain the OPC drum bright potential at constant for changes in the main charger grid voltage due to main charger grid voltage correction 1
and 2, the laser beam power must be changed accordingly. 
Laser beam power correction 2 is performed to output the laser beam power according to the above situation. 
This correction provides stable print density. 
(8) Toner concentration correction 
a. Outline and purpose
This correction is used to correct changes in the developer characteristics due to aging and change in the environmental conditions. 
When any change occurs in the developer characteristics, it causes under-toner or over-toner, resulting in improper print density. 
To prevent against this, the reference toner control level is changed according to the conditions to maintain the specified toner concentration. 
This correction provides stable print density.
b. Details of operation 
When the developing bias correction voltage (  Vdbc(n)) is minus-corrected (shifted to the positive polarity direction), it is recognized as an
increase in developing capability, and the reference toner concentration control level set with SIM 25-2 is increased. 
With the above operation, toner concentration is decreased to maintain the proper print density. 
The correction data is cleared to "0" when SIM 25-2 is executed.
TONER CONCENTRATION CORRECTION
1
99
T(time)
MAX 20
5
Operated process(DV bias correction) correction
Toner concentration
control level
Original reference toner
concentration control 
level(Set by SIM25-2)
12 – 4
(6) Main charger grid voltage correction 2
a. Outline and purpose
When the developing bias voltage is changed, the main charger grid voltage correction 2 is performed to maintain the relation between the
developing bias voltage and the main charger grid voltage at constant. 
b. Details
After the developing bias voltage correction, the voltage of correction of the developing bias voltage is automatically added to the main charger grid
voltage.
Actual main charger grid voltage variable range: –200 to –900V
(7) Laser beam power correction 2
To maintain the OPC drum bright potential at constant for changes in the main charger grid voltage due to main charger grid voltage correction 1
and 2, the laser beam power must be changed accordingly. 
Laser beam power correction 2 is performed to output the laser beam power according to the above situation. 
This correction provides stable print density. 
(8) Toner concentration correction 
a. Outline and purpose
This correction is used to correct changes in the developer characteristics due to aging and change in the environmental conditions. 
When any change occurs in the developer characteristics, it causes under-toner or over-toner, resulting in improper print density. 
To prevent against this, the reference toner control level is changed according to the conditions to maintain the specified toner concentration. 
This correction provides stable print density.
b. Details of operation 
When the developing bias correction voltage (  Vdbc(n)) is minus-corrected (shifted to the positive polarity direction), it is recognized as an
increase in developing capability, and the reference toner concentration control level set with SIM 25-2 is increased. 
With the above operation, toner concentration is decreased to maintain the proper print density. 
The correction data is cleared to "0" when SIM 25-2 is executed.
TONER CONCENTRATION CORRECTION
1
99
T(time)
MAX 20
5
Operated process(DV bias correction) correction
Toner concentration
control level
Original reference toner
concentration control 
level(Set by SIM25-2)
12 – 4
(6) Main charger grid voltage correction 2
a. Outline and purpose
When the developing bias voltage is changed, the main charger grid voltage correction 2 is performed to maintain the relation between the
developing bias voltage and the main charger grid voltage at constant. 
b. Details
After the developing bias voltage correction, the voltage of correction of the developing bias voltage is automatically added to the main charger grid
voltage.
Actual main charger grid voltage variable range: –200 to –900V
(7) Laser beam power correction 2
To maintain the OPC drum bright potential at constant for changes in the main charger grid voltage due to main charger grid voltage correction 1
and 2, the laser beam power must be changed accordingly. 
Laser beam power correction 2 is performed to output the laser beam power according to the above situation. 
This correction provides stable print density. 
(8) Toner concentration correction 
a. Outline and purpose
This correction is used to correct changes in the developer characteristics due to aging and change in the environmental conditions. 
When any change occurs in the developer characteristics, it causes under-toner or over-toner, resulting in improper print density. 
To prevent against this, the reference toner control level is changed according to the conditions to maintain the specified toner concentration. 
This correction provides stable print density.
b. Details of operation 
When the developing bias correction voltage (  Vdbc(n)) is minus-corrected (shifted to the positive polarity direction), it is recognized as an
increase in developing capability, and the reference toner concentration control level set with SIM 25-2 is increased. 
With the above operation, toner concentration is decreased to maintain the proper print density. 
The correction data is cleared to "0" when SIM 25-2 is executed.
TONER CONCENTRATION CORRECTION
1
99
T(time)
MAX 20
5
Operated process(DV bias correction) correction
Toner concentration
control level
Original reference toner
concentration control 
level(Set by SIM25-2)
12 – 4
Page of 6
Display

Sharp AR-285 (serv.man16) Service Manual ▷ Download