DOWNLOAD Sharp AR-280 (serv.man15) Service Manual ↓ Size: 81.02 KB | Pages: 10 in PDF or view online for FREE

Model
AR-280 (serv.man15)
Pages
10
Size
81.02 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR280 285 335 Service Manual-Trouble Code List
File
ar-280-sm15.pdf
Date

Sharp AR-280 (serv.man15) Service Manual ▷ View online

SERVICE MANUAL
Digital Copier
MODEL
 AR-280/285/335
SHARP CORPORATION
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.
[ 1 ] GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-1
[ 2 ] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-1
[ 3 ] OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-1
[ 4 ] CONSUMABLE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-1
[ 5 ] INSTALLATION AND SETUP . . . . . . . . . . . . . . . . . . . . . . . . . .  5-1
[ 6 ] EXTERNAL VIEW AND INTERNAL STRUCTURE . . . . . . . . . .  6-1
[ 7 ] SETTING AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . .  7-1
[ 8 ] SIMULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-1
[ 9 ] MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9-1
[10] DISASSEMBLY AND ASSEMBLY . . . . . . . . . . . . . . . . . . . . . .  10-1
[11] TROUBLE CODE LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11-1
[12] OPERATIONAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . .  12-1
CONTENTS
(Danish)
ADVARSEL !
Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering.
Udskiftning må kun ske med batteri
af samme fabrikat og type.
Levér det brugte batteri tilbage til leverandoren.
(English)
Caution !
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the manufacturer.
Dispose of used batteries according to manufacturer’s instructions.
(Finnish)
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu.
Vaihda paristo ainoastaan laitevalmistajan suosittelemaan
tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
(French)
ATTENTION
Il y a danger d’explosion s’ il y a remplacement incorrect
de la batterie. Remplacer uniquement avec une batterie du
même type ou d’un type équivalent recommandé par 
le constructeur.
Mettre au rebut les batteries usagées conformément aux
instructions du fabricant.
(Swedish)
VARNING
Explosionsfara vid felaktigt batteribyte.
Använd samma batterityp eller en ekvivalent
typ som rekommenderas av apparattillverkaren.
Kassera använt batteri enligt fabrikantens
instruktion.
CAUTION FOR BATTERY REPLACEMENT
[11] TROUBLE CODE LIST
1. Trouble code
Trouble
code
Content of trouble
Remark
Trouble
detection
C1
00 MC trouble
PCU
C2
00 TC trouble
PCU
E7
02 Laser trouble
ICU
10 Shading trouble (Black correction)
ICU
11 Shading trouble (White correction)
ICU
13 CCD light quantity check error
ICU
F1
00 Finisher communication trouble
PCU
01 Finisher jogger shift trouble
FIN
02 Finisher transport motor
abnormality
FIN
04 Finisher elevator abnormality
FIN
05 Finisher elevator home sensor
trouble
FIN
06 Finisher shift motor abnormality
FIN
10 Finisher staple unit operation
trouble
FIN
11 Finisher pusher motor trouble
FIN
15 Finisher elevator motor trouble
FIN
80 Finisher power not supplied
FIN
F2
00 Toner control sensor open
PCU
02 Toner motor connector
unconnected
PCU
31 Process control trouble (OPC
drum surface reflection rate
abnormality)
PCU
32 Process control trouble (Drum
marking scanning trouble)
PCU
37 Drum marking sensor gain
adjustment error
PCU
39 Process section thermister open
PCU
F3
12 Copier top stage CS lift up trouble
PCU
22 Copier bottom stage CS lift up
trouble
PCU
H2
00 Thermistor open (HL1)
PCU
01 Thermistor open (HL2)
PCU
H3
00 Heat roller high temperature
detection (HL1)
PCU
01 Heat roller high temperature
detection (HL2)
PCU
H4
00 Heat roller low temperature
detection (HL1)
PCU
01 Heat roller low temperature
detection (HL2)
PCU
H5
01 3 continuous POD1 not-reaching
JAM detection
PCU
L1
00 Scanner feed trouble
PCU
L3
00 Scanner return trouble
PCU
L4
01 Main motor lock detection
PCU
L6
10 Polygon motor lock detection
ICU
L8
01 No full-wave signal
PCU
02 Full-wave signal width abnormality
PCU
U4
02 ADU alignment plate operation
abnormality
PCU
Trouble
code
Content of trouble
Remark
Trouble
detection
U5
00 RADF/SPF communication trouble
PCU
01 RADF resist sensor trouble
RADF
02 RADF expulsion sensor trouble
RADF
03 RADF timing sensor trouble
RADF
11 RADF paper feed motor operation
abnormality
RADF
U6
00 Desk communication trouble
PCU
01 Desk 1 CS lift up trouble
Desk
02 Desk 2 CS lift up trouble
Desk
08 Desk 24V power abnormality
Desk
10 Desk transport motor trouble
Desk
09 LCC lift motor trouble
LCC
20 LCC communication trouble
PCU
21 LCC transport motor trouble
LCC
22 LCC 24V power abnormality
LCC
EE EL Auto developer adjustment trouble
(Overtoner)
In SIM only PCU
EU Auto developer adjustment trouble
(Undertoner)
In SIM only PCU
PC
Personal counter not installed
ICU
– –
Auditor not ready
ICU
PF
RIC copy inhibit command
reception
ICU
E7
00 ICU communication trouble
ICU
90 ICU communication trouble
PCU
F9
00 Printer communication trouble
ICU
90 Printer communication trouble
PRT
01 PRT DRAM trouble
PRT
U9
00 Operation control communication
trouble
ICU
90 Operation control communication
trouble
OPE
U2
00 EEPROM read/write error
ICU
11 Counter check sum error
(EEPROM)
ICU
12 Adjustment value check sum error
(EEPROM)
ICU
11 – 1
2. Self diagnostics
Trouble code
Description
Main
code
Sub
code
C1
00
Content MC trouble
Detail
Main charger output error (output
released)
Trouble signal from high-voltage
transformer
Cause
Main charger improperly installed
Main charger improperly assembled
High-voltage transformer connector
removed
High-voltage harness removed or wire
broken
Check
and
remedy
Check main charger output with SIM8-2.
Check main charger connector for
disconnection.
Replace high-voltage unit.
C2
00
Content TC trouble
Detail
Transfer charger output error (output
short-circuiting)
Trouble signal from high-voltage
transformer
Cause
Transfer charger contaminated with
foreign matter
Transfer charger wire broken
High-voltage transformer connector
disconnected
Check
and
remedy
Check transfer charger output with
SIM8-6.
Replace high-voltage unit.
E7
02
Content Laser trouble
Detail
BD signal from LSU kept at OFF or ON
Cause
Connector to LSU or harness inside LSU
disconnected or wire broken
Polygon motor improperly rotating
Laser home position sensor improperly
positioned inside LSU
Laser power supply line does not have
proper voltage
Laser LED improperly lighting
ICU PWB error
Check
and
remedy
Check LSU connector for disconnection.
Check LSU operation with SIM61-1.
Check polygon motor for rotation.
Check laser LED for lighting.
Replace LSU unit.
Replace ICU PWB.
10
Content Shading trouble (black correction)
Detail
Improper CCD black reading level for
copy lamp going out
Cause
Improper installation of flat cable to CCD
unit
CCD unit error
ICU PWB error
Check
and
remedy
Check flat cable to CCD unit for
installation.
Check CCD unit.
Check ICU PWB.
Trouble code
Description
Main
code
Sub
code
E7
11
Content Shading trouble (white correction)
Detail
Improper CCD white reference plate
reading level for copy lamp lighting
Cause
Improper installation of flat cable to CCD
unit
Mirror, lens or reference white plate
contaminated
Copy lamp operation error
Improperly installed CCD unit
CCD unit error
ICD PWB error
Check
and
remedy
Clean mirror, lens, or reference white
plate.
Check copy lamp for light amount
(SIM5-3) and lighting.
Check CCD unit.
Check ICU PWB.
13
Content CCD light amount check error
Detail
Copy lamp light amount adjustment in
shading cannot be made
Cause
Copy lamp does not light (broken wire,
improper installation)
Improper installation of flat cable to CCD
unit
Improper connection of copy lamp CL
lead wire
Mirror, lens, or reference white plate
Dirt or dew
Improper output of copy lamp power
supply
Improper installation of CCD unit
CCD unit error
ICU PWB error
Check
and
remedy
Clean mirror, lens, reference white plate.
Check copy lamp for light amount
(SIM5-3) and lighting.
Check CCD unit.
Check ICU PWB.
F1
00
Content Finisher communication trouble
Detail
Communication line test error occurs
when power is turned on or after the exit
of a simulation mode.
Improper communication with sorter
Cause
Improper connection or broken wire of
connector or harness between copier
and sorter
Finisher control PWB defective
Control PWB (PCU) defective
Malfunction due to noise
Check
and
remedy
Clear by turning the power supply
OFF/ON.
Check communication line connector and
harness.
Replace Finisher control PWB or PCU
PWB.
01
Content Finisher jogger shift trouble
Detail
Jogger shift trouble
Cause
Motor lock
Motor rpm abnormality
Motor overcurrent
Finisher control PWB trouble
Check
and
remedy
Check the jogger motor operation with
SIM 3-3.
11 – 2
Page of 10
Display

Sharp AR-280 (serv.man15) Service Manual ▷ Download

  • DOWNLOAD Sharp AR-280 (serv.man15) Service Manual ↓ Size: 81.02 KB | Pages: 10 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AR-280 (serv.man15) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-280 (serv.man15) Copying Equipment. Information contained in Sharp AR-280 (serv.man15) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.