AR-235/275 ADJUSTMENTS - 5
3) Manually turn the mirror base drive pulley and bring No. 2/3 mirror
base unit into contact with the positioning plate.
At that time, if the front frame side and the rear frame side of No. 2/
3  mirror  base  unit  are  brought  into  contact  with  the  positioning
plate at the same time, the mirror base unit parallelism is proper.
If one of them is in contact with the positioning plate, perform the
adjustment of 4).
4) Loosen  the  set  screw  of  the  scanner  drive  pulley  which  is  not  in
contact with No. 2/3 mirror base unit positioning plate.
5) Without  moving  the  scanner  drive  pulley  shaft,  manually  turn  the
scanner drive pulley until the positioning plate is brought into con-
tact with No. 2/3 mirror base unit, then fix the scanner drive pulley.
6) Put  No.  2/3  mirror  base  unit  on  the  positioning  plate  again,  push
the projections on the front frame side and the rear frame side of
the copy lamp unit to the corner frame, and tighten the wire fixing
screw.
(8) Sub scanning direction (scanning direction) distortion 
adjustment (Winding pulley position adjustment)
This adjustment must be performed in the following cases:
• When the mirror base drive wire is replaced.
• When the lamp unit, or No. 2/3 mirror holder is replaced.
• When a copy as shown is made.
1) Set  A3  (11"  x  17")  white  paper  on  the  original  table  as  shown
below.
Lb
La
Original
Copy
Paper exit 
direction
Place a little clearance from 
the rear side original guide.
Glass holding plate
Fit the paper edge and 
the glass holding plate edge.
A3 (11" x 17") white paper
AR-235/275 ADJUSTMENTS - 6
2) Open the original cover and make a normal (100%) copy.
3) Measure the width of the black background at the lead edge and at
the rear edge.
If the width (La) of the black background at the lead edge is equal
that (Lb) at the rear edge, there is no need to execute the following
procedures of 4) – 7).
4) Loosen the mirror base drive pulley fixing screw on the front frame
side or on the rear frame side.
5) Tighten the fixing screw of the mirror base drive pulley.
<Adjustment specification>
La = Lb
6) Execute  the  main  scanning  direction  (FR)  distortion  balance
adjustment previously described in 2) again.
(9) Main scanning direction (FR direction) distortion 
balance adjustment (Rail height adjustment)
When there is no skew copy in the mirror base scanning direction and
there is no horizontal error (right angle to the scanning direction), the
adjustment can be made by adjusting the No. 2/3 mirror base unit rail
height.
Before  performing  this  adjustment,  be  sure  to  perform  the  horizontal
image distortion adjustment in the laser scanner section.
This adjustment must be performed in the following cases:
• When the mirror base wire is replaced.
• When the copy lamp unit and no. 2/3 mirror unit are replaced.
• When the mirror unit rail is replaced and moved.
• When a following copy is made.
1) Make an original for the adjustment.
Make  test  sheet  by  drawing  parallel  lines  at  10mm  from  the  both
ends of A3 (11" x 17") white paper as shown below. (These lines
must be correctly parallel to each other.)
2) Make  a  normal  (100%)  copy  of  the  test  sheet  on  A3  (11"  x  17")
paper. (Fit the paper edge and the glass holding plate edge.)
3) Measure  the  distances  (La,  Lb,  Lc,  Ld)  at  the  four  corners  as
shown below.
When La = Lb and Lc = Ld, no need to perform the procedures 4)
and 5).
4) Move  the  mirror  base  B  rail  position  up  and  down  (in  the  arrow
direction) to adjust.
• When La < Lb
Turn  the  mirror  base  drive  pulley  on  the  front  frame  side  in  the
arrow direction A. (Do not move the mirror base drive pulley shaft.)
• When La > Lb
Turn  the  mirror  base  drive  pulley  on  the  rear  frame  side  in  the
arrow direction A. (Do not move the mirror base drive pulley shaft.)
Paper exit direction
La: Lead edge black background width
Lb: Rear edge black background width
A
B
Rear side
Front side
Original
Copy A
Copy B
10mm
10mm
10mm
10mm
Parallel line
Parallel line
White paper
La
Lb
Ld
Lc
Paper exit
direction
AR-235/275 ADJUSTMENTS - 7
<Adjustment specification>
La = Lb, Lc = Ld
5) After completion of adjustment, manually turn the mirror base drive
pulley, scan the mirror base A and mirror base B fully, and check
that the mirror bases are not in contact with each other.
If the mirror base rail is moved extremely, the mirror base may be in
contact with the frame or the original glass. Be careful to avoid this.
(10) Main scanning direction (FR direction) magnification 
ratio adjustment (SIM 48-1)
 Before  performing  this  adjustment,  be  sure  to  check  that  the
CCD unit is properly installed.
1) Put a scale on the original table as shown below.
2) Execute SIM 48-1.
3) After  warm-up,  shading is  performed  and the current set  value of
the main scanning direction magnification ratio is displayed on the
display section in 2 digits.
4) Select the mode and press the start key again.
5) Auto correction mode (SIM48-1-1)
The  mirror  unit  moves  to  the  shading  position,  and  the  reference
width  of  the  reference  white  plate  is  scanned,  and  the  correction
value is automatically calculated from that scanned value.
The correction value is displayed and a copy is made.
6) Compare the scale image and the actual scale.
If  a  fine  adjustment  is  required,  switch  to  the  manual  correction
mode  with  the  magnification  ratio  display  key  and  perform  fine
adjustment.
7) Manual correction mode (SIM48-1-2)
Enter the set value and press the start key.
The correction value is stored and a copy is made.
<Adjustment specification>
 A judgement must be made with 200mm width, and must not be
made with 100mm width.
• Error in the auto correction mode
(11) Sub scanning direction (scanning direction) 
magnification ratio adjustment  (SIM 48-1-3)
a. OC mode in copying
Note: Execute the procedure after completion of SIM 48-1-3.
1) Put a scale on the original table as shown below, and make a nor-
mal (100%) copy.
2) Compare the scale image and the actual scale.
If necessary, perform the following adjustment procedures.
3) Execute SIM 48-1-3.
4) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
b. RSPF sub scanning direction magnification ratio
Note: Before  performing  this  adjustment,  be  sure  to  check  that  the
CCD  unit  is  properly  installed  and  that  OC  mode  adjustment  in
copying has been completed.
1) Put a scale on the original table as shown below, and make a nor-
mal (100%) copy to make a test chart.
 Since the printed copy is used as a test chart, put the scale in
paralled with the edge lines.
2) Set the test chart on the SPF and make a normal (100%) copy.
3) Compare the scale image and the actual image.
If necessary, perform the following adjustment procedures.
4) Execute SIM 48-1-4.
5) After warm-up, shading is performed.
The current front surface sub scanning direction magnification ratio
correction value is displayed in two digits on the display section.
• When La > Lb
Shift the mirror base B rail upward by the half of the difference of
La–Lb.
• When La < Lb
Shift the mirror base B rail downward by the half of the difference
of Lb–La.
Example: When La = 12mm and Lb = 9mm, shift the mirror base
B rail upward by 1.5mm.
• When 
.E >.F
Shift the mirror base B rail downward by the half of the difference
of Lc–Ld.
• When Lc < Ld
When  Lc  <  Ld,  move  the  mirror  base  B  on  the  paper  feed  side
upward.
When  moving  the  mirror  base  rail,  hold  the  mirror  base  rail  with
your hand.
Adjustment 
mode
Spec value
SIM
Set value
Setting 
range
Main scanning 
direction 
magnification 
ratio
At normal: 
±1.0%
48-1
Add 1: 0.1% 
increase
Reduce 1: 0.1% 
decrease
1 – 99
Display
Content
Major cause
Copy quantity 
display "– –"
The correction 
value 
calculated is 
over 5%.
• Improper  position  of  reference
width line of the reference white
plate
• Improper installation of CCD unit
Paper jam 
lamp ON
Reference line 
scanning error
• Defective CCD
• No reference white plate
Adjustment 
mode
Spec value
SIM
Set value
Setting 
range
Sub scanning 
direction 
magnification 
ratio (OC mode)
At normal: 
±1.0%
48-1-
3
Add 1: 
0.05% increase
Reduce 1: 
0.05% decrease
1 – 99
AR-235/275 ADJUSTMENTS - 8
6) Enter the set value and press the start key.
The set value is stored and a copy is made.
7) Execute SIM 48-1-5.
The  current  back  surface  sub  scanning  direction  magnification
ratio is displayed in two digits on the display section.
8) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
(12) Off center adjustment (SPF mode)
 Before  performing  this  adjustment,  be  sure  to  check  that  the
paper off center is properly adjusted.
1) Place  the  center  position  adjustment  test  chart  (sheet  with  a
straight line in the scan direction at the center) on the SPF.
2) Make a normal copy from the manual paper feed tray, and check
the printed copy with the test chart.
If any adjustment is required, perform the following procedure. 
3) Execute SIM 50-12.
4) After  warm-up,  shading is  performed  and the current set  value of
the  off  center  adjustment  is  displayed  on  the  display  section  in  2
digits.
5) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
(13) OC (SPF) open/close detection position adjustment
1) Execute SIM 41-3.
2) Gradually close the OC (SPF) from the full open position, and mea-
sure distance A when the display on the operation panel changes.
(See the figure below.)
Distance A = Table glass top - OC (SPF) handle rib
<Adjustment specification>
OC (SPF) open/close position A: 125 – 225mm
3) If the distance is outside the specified range, adjust the open/close
sensor attachment plate position as shown below.
(14) Original sensor adjustment (SIM 41-2, 41-4)
1) Set A3 (11" x 17") paper on the OC table.
(Keep the SPF (OC cover) open.)
2) Execute SIM 41-2.
3) Keep A=125mm, and execute SIM 41-4. (Do not put paper on the
table.)
4) Check the reaction with SIM 41-1. 
(15) SPF white correction pixel position adjustment 
(required in an SPF model when replacing the lens 
unit) (SIM63-7)
1) Fully open the SPF.
2) Execute SIM 63-7.
3) When the operation panel displays "COMPLETE," the adjustment
is completed.
4) If  the  operation  panel  displays  "ERROR,"  perform  the  following
measures.
• When the display is 0:
Check that the SPF is open.
Check that the lamp is ON. (If the lamp is OFF, check the MCU con-
nector.)
Check that the CCD harness is properly inserted into the MCU con-
nector.
• When the display is 281 or above:
1) Remove the table glass.
2) Remove the dark box.
3) Slide the  lens unit toward the front side and attach it, then exe-
cute SIM.
• When the display is 143 or below:
1) Remove the table glass.
2) Remove the dark box.
3) Slide  the  lens  unit  toward  the  rear  side  and  attach  it,  then  exe-
cute SIM.
Adjustment 
mode
Spec value
SIM
Set value
Setting 
range
Sub scanning 
direction 
magnification 
ratio (SPF mode)
At normal: 
±1.0%
48-1-4
48-1-5
Add 1: 
0.05% increase
Reduce 1: 
0.05% decrease
1 – 99
Adjustment 
mode
Spec value
SIM
Set value
Setting 
range
Original off 
center mode 
(SPF mode)
Single: Center 
± 3.0mm
50-12
Add 1: 0.1mm 
shift to R side
1 – 99
Duplex: Center 
±3.5mm
Reduce 1: 0.1mm 
shift to L side
A
 Distance <  : Shift toward A.
 Distance >  : Shift toward B.
A
B
R
F
Page of 98