55
OPTIONAL EQ
UIPMENT
SINGLE PASS FEEDER (AR-SP2)
The single pass feeder (SPF) holds up to 30 originals for automatic feeding.
Single pass feeder (AR-SP2)
PART NAMES
Specifications
Acceptable
Weight:
56 to 90 g/m
2
originals
Size:
A5 to A3
Capacity:
Up to 30 sheets provided the total aggregate
thickness does not exceed 4 mm
Detectable original
A5, A4, A4R, B4, A3
sizes
Power supply
Drawn from the copier
Weight
Approx. 5.3 kg
Dimensions
583 mm (W) x 435 mm (D) x 131 mm (H)
Document feeder tray
Feeding roller cover
Original guides
Exit area
Right side cover
As a part of our policy of continuous improvement, SHARP reserves
the right to make design and specification changes for product
improvement without prior notice. The performance specification
figures indicated are nominal values of production units. There may
be some deviations from these values in individual units.
p53-68-201UK.p65
10/01/01, 10:43
55
56
OPTIONAL EQUIPMENT
SINGLE PASS FEEDER (AR-SP2)
Using the SPF
Be sure to remove any staples or paper clips from the
originals.
Damaged or crumpled originals may misfeed in the SPF.
It is recommended that these originals be copied from the
original table.
Before placing curled or wavy originals into the document
feeder tray, be sure to flatten them. If not, original misfeeds
may result.
For best feeding of originals which have binding holes
punched into them, insert them so that the holes are
positioned to the right or along the side guides.
Special originals such as transparency film and tracing
paper should not be fed through the SPF but should be
copied from the original table.
Single pass feeder (AR-SP2)
Stream feeding mode
If the stream feeding mode has been enabled using user program
No. 4, the SPF indicator will continue to blink for approximately
5 seconds after feeding of all originals is completed. While this
indicator is blinking, any new originals placed in the SPF will be
fed and copied automatically. See page 35, USER PROGRAMS.
1
Ensure that no original is left on the original table.
2
Adjust the original guides to the size of the originals.
3
Set the originals face up in the document feeder tray.
The SPF indicator will light up. If this indicator does not light up, the
originals are not properly set or the SPF is not properly closed.
The ORIGINAL SIZE indicator for the detected original size will light
up, and the paper tray with the corresponding paper size will be
automatically selected.
The auto paper select function can be disabled using user program No.
8. If this function has been disabled, use the TRAY SELECT key to
select the desired paper tray. See page 35, USER PROGRAMS.
To copy onto a different size paper, use the TRAY SELECT key to
make the selection.
The bypass tray cannot be automatically selected.
4
Set the number of copies and press the START key.
Press the CLEAR key to stop copying in the middle of a run.
If the offset stack mode is enabled using user program No. 19, each set
of copies will be offset from the previous set in the sort and group
modes.
p53-68-201UK.p65
10/01/01, 10:43
56
57
OPTIONAL EQ
UIPMENT
SINGLE PASS FEEDER (AR-SP2)
Misfeed removal
Location A
Location B
Location C
Single pass feeder (AR-SP2)
If an original misfeed occurs in the SPF, the copier will
stop and the red indicator which indicates an original
misfeed will blink.
1
Open the feeding roller cover and pull the original gently
to the left and out from the document feeder tray. Close
the feeding roller cover.
2
If the misfed original cannot be removed in step 1, open
the right side cover and remove the misfed original.
Close the right side cover.
3
If the misfed original cannot be removed in steps 1 and
2, remove the misfed original from the exit area. Open
the document feeder cover and rotate the roller in the
direction indicated by the arrow if needed.
If the misfed original cannot be easily removed from the
exit area, open the front part of the document feeder tray
to remove the original.
4
Open and close the document feeder cover to cancel the
misfeed location indicator.
After misfed originals are removed, a number may
appear in the copy quantity display, indicating the
number of originals that must be returned to the
document feeder tray. Return the originals and press
the START key to resume copying.
A
C
B
Feeding roller cover
Right side cover
Roller
p53-68-201UK.p65
10/01/01, 10:43
57
58
OPTIONAL EQUIPMENT
Electronic sorting kit (AR-EB3)
Original
Paper
Copy
Rotation copying
If user program No. 7 is set, the image of the original will rotate when the
orientation of the original does not match that of the copy paper. Rotation
copying will function only if the AUTO PAPER SELECT mode or AUTO
IMAGE mode has been selected. Even if user program No. 7 is not set,
rotation copying will function when the 2 in 1 or 4 in 1 function is selected.
See page 35. However, if enlargement copying onto a paper size larger than
A4 is performed, the image cannot be rotated.
When this occurs, the detected size and orientation of the original will be
indicated by a steadily lighted indicator and a flashing indicator will show the
required orientation of the original. The original must be rotated 90° to match
the flashing indicator to prevent image loss on the copies.
Example: Copying from an A3 original onto A4 paper
ELECTRONIC SORTING KIT (AR-EB3)
If an electronic sorting kit (AR-EB3) is installed, the copier can perform
several additional useful functions. These functions are 2 in 1 and 4 in 1,
erase, margin shift, and sort/group functions. Also, rotation copying can be
performed and a multiple number of originals can be scanned and stored into
the memory. The memory can be expanded by adding commercially available
memories recommended by SHARP. For details, contact your dealer.
To use the 2 in 1 or 4 in 1 and sort/group functions, an
optional SPF is needed. When installing an electronic
sorting kit, it is recommended to install an optional SPF.
p53-68-201UK.p65
10/01/01, 10:43
58
Page of 80