Sharp AR-150 (serv.man10) Service Manual ▷ View online
(2) Soft switch clear mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 0, 2.
02:SOFT SW CLEAR
1:OK 2:CANCEL
1:OK 2:CANCEL
4
Press 1.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
The soft switches setup is reset to the default,
and this mode is terminated.
and this mode is terminated.
(3) ROM & RAM check mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 0, 3.
03:ROM/RAM CHECK
4
(Normal case)
ROM/RAM OK
(RAM error)
RAM ERROR
Two short beeps
(ROM error)
ROM ERROR
One short beep
(4) Signal send mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 0, 4.
04:SIGNAL SEND
SELECT SIGNAL
SELECT SIGNAL
4
Press
← or → repeatedly to select the target
signal.
<signal type>
PRESS ENTER KEY
PRESS ENTER KEY
For <signal type>, refer to TABLE-3.
5
When the target signal is displayed, press ENTER.
mode # = 1
→ 10
mode # = 2
→ 20
mode # = 3
∼ 6 → 30
mode # = 7
→ 40
10
1:NO SIGNAL
The relay is turned ON.
11
Press STOP.
04:SIGNAL SEND
SELECT SIGNAL
SELECT SIGNAL
The relay is turned OFF.
“NO SIGNAL” mode is terminated.
“NO SIGNAL” mode is terminated.
12
(To terminate this mode)
Press STOP.
Press STOP.
This mode is terminated.
20
2:DTMF
DTMF # =
DTMF # =
21
Press any NUM key(0
∼ 9) or ∗ or #.
2:DTMF
DTMF # = <pressed key>
DTMF # = <pressed key>
The DTMF signal corresponding to the
pressed key is sent.
pressed key is sent.
22
Press STOP.
2:DTMF
DTMF # =
DTMF # =
23
(To continue)
Go to 21.
Go to 21.
(To change the signal kind)
Press STOP.
Press STOP.
04:SIGNAL SEND
SELECT SIGNAL
SELECT SIGNAL
(To terminate this mode)
Press STOP twice.
Press STOP twice.
This mode is terminated.
30
<signal type>
SELECT SPEED
SELECT SPEED
31
Press
← or → to select the target speed.
<signal speed>
PRESS ENTER KEY
PRESS ENTER KEY
For <signal speed>, refer to TABLE-4.
AR-F151
9 – 16
Procedure
LCD
Operation
32
When the target speed is displayed, press ENTER.
<signal speed>
SELECT DATA
SELECT DATA
33
Press
← or → to select the target data to be sent.
<data>
PRESS ENTER KEY
PRESS ENTER KEY
For <data>, refer to TABLE-5.
34
When the target data is displayed, press ENTER.
<signal speed>
<data>
<data>
The selected signal is sent.
35
Press STOP.
<signal speed>
SELECT DATA
SELECT DATA
Signal send stop
36
(To change data only)
Go to 33.
Go to 33.
(To change speed)
Press STOP.
Press STOP.
<signal type>
SELECT SPEED
SELECT SPEED
(To change the signal kind)
Press STOP twice.
Press STOP twice.
04:SIGNAL SEND
SELECT SIGNAL
SELECT SIGNAL
(To terminate this mode)
Press STOP 3 times.
Press STOP 3 times.
This mode is terminated.
40
7:TONE
SELECT FREQUENCY
SELECT FREQUENCY
41
Press
← or → to select the target frequency.
<signal freq.>
PRESS ENTER KEY
PRESS ENTER KEY
For <signal freq.>, refer to TABLE-4.
42
When the target frequency is displayed, press
ENTER.
ENTER.
<signal freq.>
The selected signal is sent.
43
Press STOP.
7:TONE
SELECT FREQUENCY
SELECT FREQUENCY
Signal send stop
44
(To change the frequency only)
Go to 41.
Go to 41.
(To change the signal kind)
Press STOP.
Press STOP.
04:SIGNAL SEND
SELECT SIGNAL
SELECT SIGNAL
(To terminate this mode)
Press STOP twice.
Press STOP twice.
This mode is terminated.
TABLE-3: Signals in the Signal send mode
MODE #
MENU
DISPLAY
1
No signal
1:NO SIGNAL
2
DTMF
2:DTMF
3
V.17
3:V.17
4
V.29
4:V.29
5
V27ter
5:V27ter
6
FLAG
6:FLAG
7
Tone (CED/CNG)
7:TONE
TABLE-4: Speed/Frequency in the Signal send mode
MODE #
MENU ITEM 1
MENU ITEM 2
MENU ITEM 3
MENU ITEM 4
3
1:V.17 14400BPS
2:V.17 12000BPS
3:V.17 9600BPS
4:V.17 7200BPS
4
1:V.29 9600BPS
2:V.29 7200BPS
5
1:V27ter 4800BPS
2:V27ter 2400BPS
6
1:FLAG 300BPS
7
1:TONE 2100Hz
2:TONE 1100Hz
TABLE-5: Data which is sent in the Signal send mode
MODE #
MENU (DATA)
DISPLAY
1
00000000b
1:00000000b
2
11111111b
2:11111111b
3
01010101b
3:01010101b
AR-F151
9 – 17
(5) Image memory clear mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 1, 0.
10:IMAGE MEM CLEAR
1:OK 2:CANCEL
1:OK 2:CANCEL
4
Press 1.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
The image data are cleared and this mode is
terminated.
terminated.
(6) Dial test / adjustment mode (Pulse 10PPS)
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 1, 4.
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
MAKE RATIO = ##%
The current make ratio setup is displayed on ##.
4
Press
← or →.
(If there is no need to adjust, no need to press.)
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
MAKE RATIO = ##%
Press
← to decrease by 1%.
Press
→ to increase by 1%.
5
Press ENTER.
“1590” is dialed.
6
(Adjustment/test end)
Press STOP.
Press STOP.
This mode is terminated.
(To continue adjustment/test)
Return to 4.
Return to 4.
(7) Dial test mode (Tone)
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 1, 6.
16:DIAL TEST TONE
“123456789
∗0#” is dialed.
This mode is terminated.
(8) Print out soft switch mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 2, 1.
21:PRINT SOFT SW
The soft switch list is printed.
This mode is terminated.
This mode is terminated.
AR-F151
9 – 18
(9) Panel check mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 4, 2.
42:FAX PANEL TEST
4
Press any key.
42:FAX PANEL TEST
<key name>
<key name>
The name of the pressed key is displayed in the
lower stage of the LCD.
lower stage of the LCD.
5
Press STOP.
This mode is terminated.
(10) Signal detect mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 4, 3.
43:SIG. DETECT
4
(When DTMF signal is detected)
43:SIG. DETECT
DTMF:<number>
DTMF:<number>
(When CNG signal is detected)
43:SIG. DETECT
CNG
CNG
(When QUIET signal is detected)
43:SIG. DETECT
QUIET
QUIET
(To terminate this mode)
Press STOP.
Press STOP.
This mode is terminated.
(11) Long distance comm select mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
SELECT MENU(
← →)
3
Press 4, 4.
44:LONG DIST COMM
1:SET 2:CLEAR
1:SET 2:CLEAR
To terminate this mode, press STOP.
4
Select the mode.
To register
→ 10
To cancel registration
→ 20
10
Press 1.
SET
ENTER # OR RAPID
ENTER # OR RAPID
11
Press the desired one touch key or the speed
dial (2 digits) to be registered.
dial (2 digits) to be registered.
SELECT SPEED
1:9600BPS 2:4800BPS
1:9600BPS 2:4800BPS
12
Select the speed. (Press 1 or 2.)
<Name or Number>
STORED
STORED
13
Return to 3.
20
Press 2.
CLEAR
ENTER # OR RAPID
ENTER # OR RAPID
21
Press the desired one-touch key or speed dial (2
digits) to be canceled.
digits) to be canceled.
<Name or Number>
CLEARED
CLEARED
22
Return to 3.
Note:
● One-touch keys and speed dials which are not registered cannot be designated.
● One-touch keys and speed dials which are not registered cannot be designated.
● When one-touch keys and speed dials which are registered are canceled, this setup is also canceled.
● The group key and the polling key cannot be designated.
AR-F151
9 – 19
Click on the first or last page to see other AR-150 (serv.man10) service manuals if exist.