Sharp AR-121E (serv.man2) Service Manual ▷ View online
4) Insert Toner unit carefully into the copier.
5) Insert until the hook is engaged with the copier as shown in the fig-
5) Insert until the hook is engaged with the copier as shown in the fig-
ure below.
6) Pull out the shutter in the arrow direction.
Note: Do not hold and carry the shutter. Otherwise the shutter may
drop and Toner unit may drop.
7) Completion of Toner unit installation
Close the front and side cabinets.
4. TD cartridge replacement
1) Open the front and side cabinets of the copier.
2) Keep holding Toner lover, and
3) Carefully pull out Toner unit from the copier.
2) Keep holding Toner lover, and
3) Carefully pull out Toner unit from the copier.
4) Put Toner unit in a collection bag immediately after removing it from
the copier
Note: Never carry exposed Toner unit. Be sure to put it in the col-
lection bag.
1
3
2
AR-151E
2 – 3
[3] SIMULATIONS
1. List of simulations
The table below shows the simulations which are not provided for the AR-120E/150E but newly added to the AR-121E/151E.
Simulation 26-38 of the SR-120E/150E is deleted in the AR-121E/151E.
Simulation 26-38 of the SR-120E/150E is deleted in the AR-121E/151E.
Main code
Sub code
Contents
24
Special counter clear
06
Developer counter clear
26
Various setup
37
55
55
Cancel of stop at developer over
CRUM destination display
CRUM destination display
46
Exposure adjustment
19
γ
Table adjustment (Copy mode)
2. Contents of simulations
Main code
Sub code
Content
24
06
Developer counter clear
When the PRINT switch is pressed, the developer count value is reset to 0.
When the PRINT switch is pressed, the developer count value is reset to 0.
26
37
Cancel of stop at developer life over
When this simulation is executed, the current set code is displayed. Enter a new code and press the PRINT
switch, and the entered code is registered.
When this simulation is executed, the current set code is displayed. Enter a new code and press the PRINT
switch, and the entered code is registered.
55
CRUM destination display
When this simulation is executed, the current setup of the CRUM destination stored in the machine is displayed.
When this simulation is executed, the current setup of the CRUM destination stored in the machine is displayed.
46
19
γ
table setup
When this simulation is executed, the currently set gamma table code number is displayed. Enter the code
number corresponding to your desired gamma table and press the PRINT switch, and the setup will be changed.
number corresponding to your desired gamma table and press the PRINT switch, and the setup will be changed.
Code number
Setting
0
Stop at developer life over
1
Stop cancel at developer life over
Code number
Setting
00
No setup
01
BTA-A
02
BTA-B
03
BTA-C
Code number
γ
table
1
Japan
2
EX Japan
AR-151E
3 – 1
[4] USER PROGRAM
The conditions of factory setting can be changed according to the use conditions.
Functions which can be set with the user program
Function
Contents
Factory setting
Auto clear time
●
When a certain time is passed after completion of copying, this function returns to the initial state
automatically. The time to reach the initial state can be set in the range of 30 sec to 120 sec by
the unit of 30 sec. This function can be disabled.
automatically. The time to reach the initial state can be set in the range of 30 sec to 120 sec by
the unit of 30 sec. This function can be disabled.
60 sec
Preheat
●
When the copier is left unused with the power ON, the power consumption is automatically reduced
to about 40Wh/H (
to about 40Wh/H (
∗
Note).
The time to start this function can be set in the range of 30 sec to 90 sec by the unit of 30 sec.
This function cannot be disabled.
This function cannot be disabled.
90 sec
●
When this function is operated, the pre-heat lamp on the operation panel lights up.
To return to the initial state, press any key on the operation panel. (When the COPY button is
pressed, a copy is made after returning to the initial state.)
To return to the initial state, press any key on the operation panel. (When the COPY button is
pressed, a copy is made after returning to the initial state.)
Auto shut off timer
●
When the copier is left unused with the power ON, the power consumption is automatically reduced
to about 18Wh/H (
to about 18Wh/H (
∗
Note). The time to start this function can be set in the range of 2 min to 120
min.
5 min
●
When this function is operated, all the lamps except for the pre-heat lamp on the operation panel
turn off.
To return to the initial state, press the COPY button.
turn off.
To return to the initial state, press the COPY button.
Stream feeding
Only models with SPF.
Cancel
Auto shut off
●
Used to set or cancel this function.
Set
∗
Note: The power consumption values in preheat and auto shut off may be varied depending on the use conditions.
Setting the power save modes, auto clear time,
and stream feeding mode
and stream feeding mode
1) Press and hold down the light ( ) and dark ( ) keys simul-
taneously for more than 5 seconds until all the alarm indicators
( , , and ) blink and "- -" appears in the display.
( , , and ) blink and "- -" appears in the display.
2) Use the left copy quantity ( ) key to select a user program num-
ber (1: auto clear time, 2: preheat mode, 3: auto power shut-off
timer, 4: stream feeding mode, 5: auto power shut-off mode). The
selected number will blink in the left side of the display.
timer, 4: stream feeding mode, 5: auto power shut-off mode). The
selected number will blink in the left side of the display.
Function name
Function code
Auto clear time
1
Preheat
2
Auto shut off timer
3
Stream feeding
4
✽
Auto shut off
5
[Cancel] If a wrong code is entered, press the clear key and enter the
correct function code.
∗
SPF only
∗
The remaining toner quantity is displayed by pressing the % key for 5 sec before entering a program code in the user simulation mode.
3) Press the print ( ) key. The entered program number will be steadily lit and the currently selected parameter number for the program will blink
on the right side of the display.
4) Select the desired parameter using the right copy quantity ( ) key. The entered parameter number will blink on the right of the display.
Function
name
name
Set code
Function
name
name
Set code
Function
name
name
Set code
Function
name
name
Set code
Function
name
name
Set code
Auto clear
time
time
0 (Cancel)
Preheat
0 (30 sec)
Auto shut
off timer
off timer
0 (2 min)
Stream
feeding
feeding
∗
0 (Cancel)
Auto shut
off
off
0 (Cancel)
1 (30 sec)
1 (60 sec)
∗
1 (5 min)
1 (Setting)
∗
1 (Setting)
∗
2 (60 sec)
∗
2 (90 sec)
2 (15 min)
3 (90 sec)
3 (30 min)
4 (120 sec)
4 (60 min)
5 (10 sec)
5 (120 min)
∗
: Factory setting
5) Press the print ( ) key. The right-hand number in the display will be steadily lit and the entered value will be stored.
Note: To change the setting or to set another mode, press the clear ( ) key. The copier will return to step 2).
6) Press the light ( ) or dark ( ) key to return to the normal copy mode.
AR-151E
4 – 1
[5] MAINTENANCE
1. Maintenance table
✕
: Check (Clean, adjust, or replace when required.) : Clean
▲
:
Replace :
Adjust
✩
: Lubricate
Section
Parts
25K
50K
75K
100K
125
Remark
Developing
Developer
▲
▲
▲
▲
▲
DV blade
▲
▲
DV side seal (F/R)
▲
▲
Process peripheral
Drum
▲
▲
▲
▲
▲
2. Maintenance display system
Toner
Life
7.2K
Remaining
quantity check
quantity check
∗
1
a.
Press and hold the density adjustment LIGHT key for more than 5 sec, and the machine will enter the
user program mode.
user program mode.
b.
Press and hold the "%" key for more than 5 sec, and the remaining quantity will be displayed on the
copy quantity display in one of the following levels: (Remaining quantity display levels: 100%, 75%,
50%, 25%, 10%, LO)
copy quantity display in one of the following levels: (Remaining quantity display levels: 100%, 75%,
50%, 25%, 10%, LO)
c.
Press the density adjustment LIGHT key to cancel.
Remaining
quantity
quantity
NEAR EMPTY
About 10%
About 10%
EMPTY
LED
ON
Flash
Machine
Operation allowed
Stop
Developer
Life
25K
LED
ON at 25K of the developer count.
Machine
Selection is available between Not Stop and Stop by Service Simulation (SIM 26-37) Setup.
(If Stop is selected, the LED will flash and stop at 25K.)
(If Stop is selected, the LED will flash and stop at 25K.)
∗
Default: Not Stop
∗
Clear: SIM 24-06
Maintenance
LED
Selection is available among 18K, 13K, 9K, 6K, 3K, and free (no lighting) with SIM 21-1.
∗
Default: free
∗
Clear: SIM 20-1
Machine
Not stop.
∗
1: Installation of a new toner cartridge allows to display the remaining quantity.
AR-151E
5 – 1
Click on the first or last page to see other AR-121E (serv.man2) service manuals if exist.