Remove the side sheets on the both sides of DV box unit.
Clean the DV box unit with alcohol and reattach the side sheets F and R to the both sides.
0
0 . 5
0
0.5
0
0.5
0
0 . 5
.Remove glue completely before reattaching. 
.After drying alcohol, attach the  side sheet F,R. 
DV box unit F side
DV box unit R side
Remove the DV molt F,R and DV molt and clean with alcohol. 
After attaching the DV molt F and R, attach the DV molt with the
DV molt R edge as the reference. 
.Do not allow clearance between DV molt  and DV molt F. 
(Pull and attach them. Overlap may be allowed.)
.Remove glue completely before reattaching. 
.After drying alcohol, attach the DV side sheet. 
When attaching the DV molt F,
 projection in the arrow
 direction is not allowed. 
When attaching the DV molt R,
 projection in the arrow
 direction is not allowed. 
[The reattachment procedure]
0
0.5
0
0.5
0
0.5
0
0.5
00
.5
0
0.5
0
1
00
.5
0
0.5
DV molt F attachment 
reference 
(DV box edge)
DV molt attachment 
reference 
(DV box edge)
DV molt 
attachment 
reference 
(DV box edge)
DV molt 
attachment 
reference 
(DV box edge)
DV molt  R
attachment 
reference 
(DV box edge)
AR-150E
3  –  5
B. Drum unit
1) Check the external view.
Check for damage or cracks on the boss and the boss hole. 
Check to insure that the waste toner pipe shutter slides smooth-
ly.
Check to insure that the star ring and the CRU washer rotate
smoothly. 
2) Remove the drum cover. (4 Lock Tabs)
3) Remove the drum fixing plate and the photoconductor drum.
(Note) Dispose the drum fixing plate which was removed. 
4) Check the cleaning blade and the red felt for no damage. 
If there is any damage, execute all procedures from item 5) and
later. 
If there is no damage, execute the procedure of item 12). 
5) Remove the main charger. 
(Cleaning the screen grid and the sawteeth.)
6) Remove the cleaning blade. 
Note: Dispose the cleaning blade which was removed. 
(2)
(3)
L
O
C
K
AR-150E
3  –  6
  7) Clean the cleaning section and the waste toner pipe to remove
waste toner completely with a vacuum cleaner. 
  8) Remove the felt and duplex tape completely. 
  Note: Be careful not to scratch or bend the sub blade. 
  9) Attach the cleaning blade.
Securely insert the plate section of the cleaning blade into the
dove and fix it with a screw.
Do not touch the cleaning blade rubber with your hand.
When attaching the cleaning blade, press the cleaning blade in the
arrow direction and attach.
10) Attach the felt. 
Attach the mocket with slightly pressing section A of the cleaning blade.
Do not touch the tip of the cleaning blade.
Do not put the mocket under the cleaning blade.
Do not put the mocket on the sub blade.
Do not press the sub blade with the mocket.
11) Attach the main charger.
Securely set the MC holder on the projection of the process frame.
Securely insert two projections of the MC holder into the groove
in the process frame.
When attaching the MC holder ass’y, be careful not to make con-
tact with the cleaning blade.
12) Attach the drum fixing plate and the photoconductor drum.
Apply grease to the inside of the photoconductor drum. (Dia. 2)
Attach the drum from (b). (Prevention against the sub blade edge
breakage)
Attach the drum so that its position with the sub blade is as shown.
13) Attach the detection gear.
Note:
The detection gear is not installed to the drum cartridge packed
with the main body. Add a new one.
14) Attach the drum cover.
Note: After attaching the drum cover, do not make a copy.
When attaching the drum cover, engage the detection gear
20T rib with the 30T gear rib, and attach the drum cover to
the process frame.
15) Mark the number of times of recycling on the side of the cover with
white paint. 
Max. times of recycling: 5 times
Note: Another method of cleaning the drum counter is avail-
able with SIM 24-07.
AR-150E
3  –  7
[4] SIMULATIONS
The following items are added in this model. (Not provided in the AL series.)
1. List of simulations
Main code
Sub code
Contents
5
Lamp ON check
01
02
03
Operation panel display check (Maintenance lamp added)
Fusing lamp ON + cooling fan high speed/low speed
Copy lamp ON
20
Maintenance
counter clear
01
21
Counter setup
(In
maintenance)
01
Maintenance cycle setup
22
Counter display
01
02
05
12
14
21
Maintenance counter
Maintenance preset value
Total counter
Drum counter
P-ROM version display
Scanner counter
2. Contents of simulations
Main code
Sub code
Contents
Details of operation
20
01
Maintenance
counter clear
When the PRINT switch is pressed, the maintenance count value is cleared and the
value (000000) is displayed.
21
01
Maintenance
cycle setup
The code of the currently set maintenance cycle value is displayed (initial display), and
the set data is stored.
22
01
Maintenance
counter display
The display method is similar to the total counter display.
02
Maintenance
reset value
display
The quantity corresponding to the code set with 21-01 is displayed.
The display method is similar to the total counter display.
05
Total counter
display
The total counter value is displayed in 3 digits x 2 times repeatedly.
12
Drum counter
display
The display method is similar to the total counter display.
14
P-ROM version
display
The P-ROM version is displayed in 3 digits on the value display section.
(In the AR model, the 100% zoom lamp is displayed.)
21
Scanner
counter display
The display method is similar to the total counter display.
Key operation/Display
Code
Setup
0
3,000 pages
1
6,000 pages
2
9,000 pages
3
13,000 pages
4
18,000 pages
5
Free (999,999 pages) 
 Default
Display
(example: 12345)
012 
→ Blank → 345 → Blank → 012
0.7s  0.3s  0.7s  1.0s  0.7s
AR-150E
4 – 1
Page of 13
Display