Sharp AL-1611 (serv.man10) Service Manual ▷ View online
AL-1611/AL-1622
SIMULATIONS
8 – 5
*
1: Each counter display method
To display 123456: 123 (0.75 sec)
3
Blank (0.35 sec)
3
456 (0.75 sec)
3
Blank (1.0 sec)
3
repetition
*
2: Display after clearing each counter
000 (0.75 sec)
3
Blank (0.35 sec)
3
000 (0.75 sec)
3
Blank (1.0 sec)
3
Repetition
Main
code
code
Sub
code
Contents
Details of operation
Initial
value
value
Set range
21
2
Mini maintenance cycle set-
ting
ting
Used to display the currently set mini maintenance cycle at the numbers
shown at right. When the set value is entered and the start key is pressed, the
set value is stored.
shown at right. When the set value is entered and the start key is pressed, the
set value is stored.
4
0 ~ 4
22
1
Maintenance counter display Used to display the current maintenance counter value.
*
1
2
Maintenance preset value
display
display
Used to display the current maintenance preset value (set with SIM 21-1).
*
1
3
JAM memory display
Used to display a JAM generated during copying on the JAM position display
on the operation panel. Max. 30 recent jams are stored. JAM No. 1 is dis-
played even when there is no JAM.
on the operation panel. Max. 30 recent jams are stored. JAM No. 1 is dis-
played even when there is no JAM.
4
Total JAM counter display
Used to display the current total JAM counter value.
*
1
5
Total counter display
Used to display the current total counter value.
*
1
6
Developing counter display
Used to display the current developing unit counter value.
*
1
7
Developing preset counter
value display
value display
Used to display the current mini maintenance preset value (set with SIM 21-2).
*
1
8
SPF counter display
<Only AL-1622>
<Only AL-1622>
Used to display the current SPF counter value.
*
1
9
Paper feed counter display
Used to display the current paper feed counter value for each paper feed port.
*
1
12
Drum counter display
Used to display the current drum counter value.
*
1
14
Copier ROM version display
Used to display the version number of the main ROM.
15
Trouble memory display
Used to display the actually occurred trouble codes on the display on the
operation panel. When the start key is pressed during the main code display,
the sub code is displayed. Max. 20 recent trouble codes are stored.
operation panel. When the start key is pressed during the main code display,
the sub code is displayed. Max. 20 recent trouble codes are stored.
Key operation/Display
0: 2500 sheets
1: 5000 sheets
2: 10000 sheets
3: FREE (999999 sheets)
3: FREE (999999 sheets)
4: 30000 sheets (When toner save is OFF)
50000 sheets (When toner save is ON)
Key operation
Display
JAM history select:
Magnification ratio display key
The history number (1 ~ 30) is
displayed on the display.
The JAM position LED correspond-
ing to the history number is lighted.
displayed on the display.
The JAM position LED correspond-
ing to the history number is lighted.
Key operation
Paper feed port selection: Tray select key
Display
(Example) When the ROM version is 4.01:
004
3
Blank
3
001
3
Blank
3
Repetition
Key operation
Display
Sub code display: Start key
Trouble code history select:
Magnification ratio display key
Histories 1 ~ 10: The upper digit of
display "A" ~ "J" lights up.
Histories 11 ~ 20: The upper digit of
display "A" ~ "J" blinks.
• Display without trouble code Main
code: "– –"
Sub code: "00"
Sub code: "00"
AL-1611/AL-1622
SIMULATIONS
8 – 6
*
2: Display after clearing each counter
000 (0.75 sec)
3
Blank (0.35 sec)
3
000 (0.75 sec)
3
Blank (1.0 sec)
3
Repetition
Main
code
code
Sub
code
Contents
Details of operation
Initial
value
value
Set range
22
16
Duplex print counter display
<Not Used>
Used to display the current duplex print counter value.
*
1
17
Copy counter display
Used to display the current copy counter value.
*
1
18
Printer counter display
<Not Used>
Used to display the current printer counter value.
*
1
19
Electronic sort counter dis-
play
<Not Used>
play
<Not Used>
Used to display the current electronic sort counter value.
*
1
21
Scanner counter display
Used to display the current scanner counter value.
24
1
JAM memory, JAM counter
clear
clear
Used to clear the JAM memory and the JAM counter.
*
2
2
Trouble memory clear
Used to clear the trouble memory.
*
2
4
SPF counter clear
<Only AL-1622>
Used to clear the SPF counter.
*
2
5
Duplex counter clear
<Not Used>
<Not Used>
Used to clear the duplex counter.
*
2
6
Paper feed counter clear
Used to clear the paper feed counter.
*
2
7
Drum counter clear
Used to clear the drum counter.
*
2
8
Copy counter clear
Used to clear the copy counter.
*
2
9
Printer counter clear
<Not Used>
Used to clear the printer counter.
*
2
10
Electronic sort counter clear
<Not Used>
Used to clear the electronic sort counter.
*
2
13
Scanner counter clear
Used to clear the scanner counter.
*
2
25
1
Main motor operation check
Execute the simulation with the developer cartridge removed, and the main
motor will rotate for 30 sec. At that time, the cooling motor rotates at a low
speed.
motor will rotate for 30 sec. At that time, the cooling motor rotates at a low
speed.
10
Polygon motor operation
check
check
Used to drive the polygon motor for 30 sec.
AL-1611/AL-1622
SIMULATIONS
8 – 7
Main
code
code
Sub
code
Contents
Details of operation
Initial
value
value
Set range
26
1
Option switch display
<Not Used>
Used to display the installed option on the operation panel. (The LED corre-
sponding to the installed option is lighted.)
sponding to the installed option is lighted.)
3
Auditor setting
Used to display the current auditor setting with the numbers at right. After
entering the set value, press the start key, and the set value is stored.
entering the set value, press the start key, and the set value is stored.
0
0 ~ 2
5
Counter mode setting
Used to set the print counter mode in A3.
Used to display the currently set counter value with the numbers at right. After
entering the set value, press the start key, and the set value is stored.
Used to display the currently set counter value with the numbers at right. After
entering the set value, press the start key, and the set value is stored.
0
0 ~ 3
6
Destination setting
Used to display the current destination setting with the numbers at right.
After entering the set value, press the start key, and the set value is stored.
After entering the set value, press the start key, and the set value is stored.
8
0 ~ 13
Key operation
Display
Display select:
Magnification
ratio display key
ratio display key
<Lighting with an option installed>
When "A" is displayed:
Shifter: Paper empty LED
Shifter: Paper empty LED
Job separator: JAM LED
SPF: SPF select LED
RSPF: SPF JAM LED
RSPF: SPF JAM LED
Duplex mode: Main cassette select LED
Simplex mode: Multi manual paper feed select LED
MCU JMPER1: Top of the magnification ratio display
MCU JMPER1: Top of the magnification ratio display
MCU JMPER2: 2nd of the magnification ratio display
MCU JMPER3: 3rd of the magnification ratio display
MCU JMPER7: 4th of the magnification ratio display
MCU JMPER7: 4th of the magnification ratio display
MCU JMPER7: 5th of the magnification ratio display
MCU JMPER7: 6th of the magnification ratio display
MCU JMPER7: 7th of the magnification ratio display
MCU JMPER7: 7th of the magnification ratio display
MCU JMPER8: Bottom of the magnification ratio display
When "b" is displayed:
Cassette (2nd step): No. 2 cassette select LED
Cassette (2nd step): No. 2 cassette select LED
Cassette (3rd step): No. 3 cassette select LED
Cassette (4th step): No. 4 cassette select LED
Memory installed: Paper empty LED
Memory installed: Paper empty LED
FAX: JAM LED
Printer: Main body JAM LED
ERDH: Main cassette select LED
ERDH: Main cassette select LED
16CPM: SPF JAM LED
20CPM: SPF select LED
Document sensor: Auto paper select LED
Document sensor: Auto paper select LED
Key operation/Display
0: Built-in auditor
1: Coin vendor
1: Coin vendor
2: Others
Key operation/Display
0: Total/Developer = 2 counts
1: Total/Developer = 1 count
2: Total/Developer = 2 counts
2: Total/Developer = 2 counts
3: Total/Developer = 1 count
Maintenance = 2 counts
Maintenance = 2 counts
Maintenance = 1 count
Maintenance = 1 count
Maintenance = 1 count
Key operation/Display
0: Japan
1: USA (Inch series)
1: USA (Inch series)
2: Canada (Inch series)
3: Germany 1 (AB series)
4: UK (AB series)
4: UK (AB series)
5: Not used
6: France (AB series)
7: EX inch series
8: X AB series
9: X inch series (FC conformity)
9: X inch series (FC conformity)
10: EX AB series (FC conformity)
(Australia, Newzealand)
11: China (AB series)
11: China (AB series)
12: Taiwan (AB series)
13: Germany 2 (AB series)
AL-1611/AL-1622
SIMULATIONS
8 – 8
26
7
CRUM set value display
The currently set value of CRUM is displayed with the following numbers:
10
Model name setting
Used to set the model name of the machine used with the following numbers.
After entering the set value, press the start key and the set value is stored.
After entering the set value, press the start key and the set value is stored.
0
0 ~ 1
22
Language setting
Used to display the current setting of the language information with the num-
ber at right. After entering the set value, press the start key, and the set value
is stored.
ber at right. After entering the set value, press the start key, and the set value
is stored.
1
0 ~ 7
30
CE mark conformity control
setting
setting
Used to display the current setting of CE mark conformity control with the
number at right. After entering the set value, press the start key, and the set
value is stored.
number at right. After entering the set value, press the start key, and the set
value is stored.
1
0 ~ 1
32
Fan rotation duty change
state setup
state setup
The currently set fan motor rotation duty is displayed with the following num-
bers. After entering the set value, press the start key to store the set value.
bers. After entering the set value, press the start key to store the set value.
0
0 ~ 1
38
Cancel of stop at drum life
over
over
<Not Used>
The currently set value is displayed. After entering the set value, press the
start key to store the set value.
start key to store the set value.
1
0 ~ 1
42
Transfer timing adjustment
After completion of warm up, shading is performed and the currently set trans-
fer timing adjustment value is displayed.
fer timing adjustment value is displayed.
3
1, 3, 5, 7, 9
Main
code
code
Sub
code
Contents
Details of operation
Initial
value
value
Set range
Key operation/Display
0: Not set
1: BTA-A
2: BTA-B
2: BTA-B
3: BTA-C
99: Conv
Key operation/Display
0: AL-1611
1: AL-1622
Key operation/Display
0: Japanese
1: English
1: English
2: French
3: German
4: Italian
5: Dutch
5: Dutch
6: Swedish
7: Spanish
Key operation/Display
0: CE mark control OFF
1: CE mark control ON
1: CE mark control ON
Key operation/Display
0: Operating 50%, standby 30%
1: Operating 80%, standby 50%
1: Operating 80%, standby 50%
Key operation/Display
0: The machine stops at drum life over.
1: The machine does not stop at drum life over.
Key operation
Transfer timing adjustment value: Copy quantity keys
"1": 240 ms
"3": 260 ms
"5": 280 ms
"5": 280 ms
"7": 300 ms
"9": 320 ms
Click on the first or last page to see other AL-1611 (serv.man10) service manuals if exist.