MATERIAL  SAFETY  DATA  SHEET 
Page: 3/4
 
Date Revised: Jul. 31. 2002
 
Date Issued  : Jun.   1. 1998 
MSDS No. F-30831 
9.PHYSICAL AND CHEMICAL PROPERTIES 
Appearance 
Physical State : Solid 
Form : Powder 
Color : Black 
Odor : odorless 
Ph : Not applicable 
Boiling / Melting Point 
: Not applicable 
Flash Point(°C) 
: Not applicable 
lgnition Point(°C ) 
: No data 
Explosion Properties 
: No data 
Density(g/cm³) : 5.4   (bulk density : 2.09) 
Solubility in Water 
: Negligible 
 
10.STABILITY AND REACTIVITY 
Stability : Stable 
Hazardous Reactions 
: Dust explosion, like most finely divided organic powders. 
Conditions to Avoid 
: Electric discharge, throwing into fire. 
Materials to Avoid 
: Oxidizing Materials 
Hazardous Decomposition Products 
: CO, CO
2
 and NO
X
 
Further Information 
: None 
 
11.TOXICOLOGICAL INFORMATION 
Acute Toxicity 
Ingestion(oral) : 
LD
50
 > 2000mg/kg (Rats) 
Inhalation : 
No 
data 
Dermal                     : LD
50
>2000mg/kg(Rats) 
Eye irritation 
: Not an irritant (Rabbits) 
Skin irritation 
: Not an irritant (Rabbits) 
Skin sensitizer 
: No sensitization 
Mutagenicity : Negative (Ames Test) 
Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human carcinogen).
This classification is given to chemicals for which there is inadequate human evidence, but sufficient
animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the
development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels
that induce particle overload of the lung. Studies performed in animal models other than rats did not
show any association between carbon black and lung tumors. Moreover, a two-year cancer bioassay
using a typical toner preparation containing carbon black demonstrated no association between toner
exposure and tumor development in rats. 
Chronic Effect 
: In a study in rats of chronic inhalation exposure to a typical toner, a mild to moderate degree of lung
fibrosis was observed in 92% of the rats in the high concentration (16mg/m
3
) exposure group, and a
minimal to mild degree of fibrosis was noted in 22% of the animals in the middle (4mg/m
3
) exposure
group, but no pulmonary change was reported in the lowest (1mg/m
3
) exposure group, the most relevant
level to potential human exposures. 
 
12.ECOLOGICAL INFORMATION 
No data are available.
 
 
 
MATERIAL  SAFETY  DATA  SHEET 
Page: 4/4
 
 
Date Revised: Jul. 31. 2002
 
 
Date Issued  : Jun.   1. 1998 
 
MSDS No. F-30831 
13.DISPOSAL CONSIDERATIONS 
Waste from Residues 
: Waste material may be dumped or incinerated under conditions  which meet all federal, 
state and local environmental regulations. 
Contaminated Packaging  : Waste may be disposed or incinerated under conditions which meet all federal, state and 
local environmental regulations. 
  
 
14.TRANSPORT INFORMATION 
UN Classification 
: None 
Not classified as hazardous for transport. 
  
 
15.REGULATORY INFORMATION 
US Information 
TSCA(Toxic Substances Control Act) 
All chemical substances in this product comply with all applicable rules or order under TSCA. 
SARA(Superfund Amendments and Reauthorization Act) Title III 
302 Extreme Hazardous Substance  : None 
311/312 Hazard Classification 
: None 
EU Information 
1999/45/EC and 67/548/EEC 
Symbol & Indication 
: Not required 
R-Phrase 
: Not required 
76/769/EEC 
 
: All chemical substances in this product comply with all applicable rules 
or order under 76/769/EEC. 
  
 
16.OTHER INFORMATION 
NFPA Rating (USA) 
: Health=1 
Flammability=1 
Reactivity=0 
WHMIS Legislation (Canada) 
: This product is not a controlled product. 
References 
IARC(1996) : IARC monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Humans, Vol. 65, 
Printing Process  And Printing Inks, Carbon Black and Some Nitro Compounds, Lyon, pp.149-261  
H.Muhle, B.Bellmann, O.Creutzenberg, C.Dasenbrock, H.Ernst, R.Kilpper, J.C.MacKenzie, P.Morrow, U.Mohr, 
S.Takenaka, and R.Mermelstein(1991) Pulmonary Response to Toner upon Chronic Inhalation Exposure in Rats.
Fundamental and Applied Toxicology 17, pp.280-299. 
  
 
The information on this data sheet represents our current data and best opinion as to the proper use in handling of this 
product under normal conditions. However, all materials may present unknown hazards and should be used with caution. 
Although certain hazards are described herein, we do not guarantee that these are the only hazards which exist.
The CE mark logo label is affixed on an equipment in case that the directives described in the above sentence are
applicable to the product. (This sentence is not applicable in any country where the above directives are not required.)
Required in Appendix ZB of BS 7002 (En 60 950) – United Kingdom
MAINS PLUG WIRING INSTRUCTIONS
The mains lead of this equipment is already fitted with a mains plug which is either a non-
rewireable (moulded) or a rewireable type. Should the fuse need to be replaced, a BSI or
ASTA approved fuse to BS1362 marked 
 or 
 and of the same rating as the one
removed from the plus must be used.
Always refit the fuse cover after replacing the fuse on the moulded plug. Never use the
plug without the fuse cover fitted.
In the unlikely event of the socket outlet in your home not being compatible with the plug
supplied either cut-off the moulded plug (If this type is fitted) or remove by undoing the
screws if a rewireable plug is fitted and fit an appropriate type observing the wiring code
below.
DANGER: The fuse should be removed from the cut-off plug and the plug destroyed
immediately and disposed of in a safe manner. Under no circumstances shold the cut-off
plug be inserted elsewhere into a 13A socket outlet as a serious electric shock may occur.
To fit an appropriate plug to the mains lead, follow the instructions below:
IMPORTANT: The wires in this mains lead are coloured in accordance with the following
code:
GREEN-AND-YELLOW:
Earth
BLUE:
Neutral
BROWN:
Live
As the colours of the wires in this mains lead may not correspond with coloured markings
identifying the terminals in your plug, proceed as follows:
The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in
the plug which is marked with the letter E, or by the safety earth symbol 
, or coloured
green or green-and-yellow.
The wire which is coloured BLUE must be connected to the terminal which is marked with
the letter or coloured black.
Printed in France