DOWNLOAD Sharp AL-1457 (serv.man9) Service Manual ↓ Size: 89.92 KB | Pages: 14 in PDF or view online for FREE

Model
AL-1457 (serv.man9)
Pages
14
Size
89.92 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Sect.10 Simulations Trouble Codes
File
al-1457-sm9.pdf
Date

Sharp AL-1457 (serv.man9) Service Manual ▷ View online

AL-1457  SIMULATION, TROUBLE CODES  10 - 6
26
06
Destination setup
When this simulation is executed, the current setup of the destination code number is displayed. Enter the code number corresponding 
to the destination and press the PRINT switch to enable the setup.
07
Machine conditions check
When this simulation is executed, the current machine setup is displayed.
20
Rear edge void setup
When this simulation is executed, the current setup of the rear edge void code number is displayed. Enter the code number 
corresponding to the rear edge void and press the PRINT switch to enable the setup. 
30
CE mark support control ON/OFF
When this simulation is executed, the current setup of the CE mark support code number is displayed. Enter the code number 
corresponding to the CE mark support setup and press the PRINT switch to enable the setup. 
38
Cancel of stop at drum life over
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the PRINT 
switch to enable the setup. 
39
Memory capacity check
When this simulation is executed, the current memory capacity is displayed. 
40
Polygon motor OFF time setup (Time required for turning OFF after completion of printing)
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the PRINT 
switch to enable the setup. 
Main 
code
Sub 
code
Content
Code number
Destination
0
Inch series
1
EX JAPAN  AB series
2
JAPAN AB series
3
China (EX JAPAN AB series + Chinese paper support)
CPM
Copy quantity display
10 cpm 
10
12 cpm 
12
13 cpm
13
14 cpm
14
15 cpm 
15
Code number
Rear edge void setup
0
Rear edge void provided * Default
1
Rear edge void not provided
The default for CE-support 200V series is “1.”
Code number
CE mark support setup
0
CE mark support control OFF * Default (100V series)
1
CE mark support control ON
Code number
Setup
0
Stop at drum life over * Default (AL model)
1
Cancel of stop at drum life over
Code number
Setup
8
8  Mbyte
16
16 Mbyte
Code number
Setup
0
0 sec
1
30 sec * Default
2
60 sec
3
90 sec
AL-1457  SIMULATION, TROUBLE CODES  10 - 7
26
42
Transfer ON timing control setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed. (For any number different from the following 
ones, the default time is automatically set.)
43
Side void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the side void amount is displayed.
2. Enter the code number and press the start key. The setting is changed.
44
SPF document rear edge read setup + Fax document rear edge scan setup.
When this simulation is executed, the currently set code number is displayed. Enter the desired code number and press the START 
key, and the display will be changed. The document rear edge scanning area in SPF reduction (less than 100%) copy is changed.
The code number is changeable in the range of 0 – 8.
The default value is 4, and 2 mm of the document rear edge is cut.
When the value is changed by 1, the area is changed by 1 mm.
62
Energy-save mode copy lamp setup
Used to set half-ON (50%)/OFF of the copy lamp in the pre-heat mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the PRINT 
switch to enable the setup.
63
Fan control select setup
Used to set the cooling fan operation mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the PRINT 
switch to enable the setup.
Main 
code
Sub 
code
Content
Code number
Setting
0
Default (330 msec)
1
– 40 msec
2
– 30 msec
3
– 20 msec
4
– 10 msec
5
Default (330 msec)
6
+10 msec
7
+20 msec
8
+30 msec
9
+40 msec
Code number
Setting
0
0  mm
1
0.5 mm
2
1.0 mm
3
1.5 mm
4
2.0 mm * Default
5
2.5 mm
6
3.0 mm
7
3.5 mm
8
4.0 mm
9
4.5 mm
10
5.0 mm
Code number
Setup
0
Copy lamp half-ON (50%) * Default
1
Copy lamp OFF
Code number
Setup
1
1-speed fan control
2
2-speed fan control * Default when starting mass production
AL-1457  SIMULATION, TROUBLE CODES  10 - 8
30
01
Paper sensor status display
Indicates the paper sensor status using the lamps on the operation panel. 
43
01
Fusing temperature setup (Normal copy)
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
04
Fusing temperature setup 2
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
05
Fusing temperature setup in duplex copy
In duplex copy, this setup value is added to the fusing temperature of single copy. When this simulation is executed, the current setup 
of the code number is displayed. Enter the code number and press the PRINT switch to enable the setup. 
09
Setup of fusing control of postcard size paper
Main 
code
Sub 
code
Content
Sensor name
Display lamp
Before-resist paper sensor (PPD1)
Developer cartridge replacement lamp
Fusing section paper sensor (PPD2)
JAM lamp
Paper exit sensor (POD)
Photoconductor cartridge replacement lamp
2nd CS paper sensor (PPD3)
2nd cassette lamp
New drum cartridge sensor (PUIS)
Zoom lamp
Single manual feed paper sensor (MFD)
AE lamp
Code number
Set temperature (°C)
0
175
1
180
2
185
3
190
4
195 (* Default)
5
200
Code number
Set temperature (°C)
0
155
1
160
2
165
3
170 (* Default)
4
175
5
180
Code number
Temperature shift (°C)
0
±0°C * Default
1
– 8°C
2
– 6°C
3
– 4°C
4
– 2°C
5
±0°C
6
+2°C
7
+4°C
8
+6°C
9
+8°C
The default for Japan model is “1.”
Code number
Setup
0
Cancel * Default
1
Setup
AL-1457  SIMULATION, TROUBLE CODES  10 - 9
46
01
Copy density adjustment (300dpi)
Used to set the copy density in each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading operations are performed and the current setup is displayed in two digits 
(default: 50).
Change the setup value with the copy quantity keys. Press the PRINT switch and a copy is made according to the new setup.
The greater the setup value is, the darker the copy is. The smaller the setup value is, the brighter the copy is. Only EXP.3 copy is made 
in this simulation. When set to a darker level, Exp.1 and Exp.5 copies also become darker. When set to a brighter level, Exp.1 and 
Exp.5 copies also become brighter. Press the CLEAR key to save the setup and exit from the simulation mode.
Use the copy mode select key to select a copy mode . The setup value of the selected copy mode is displayed on the copy quantity 
display.
(adjustment range: 0 – 99) 
02
Copy density adjustment (600dpi)
Used to set the copy density in each mode.
(Operation/Procedure)
When this simulation is executed, the machine performs warm-up and shading, and the current setup value is displayed in two digits. 
(Default: 50)
Use the copy quantity key to change the setup value, and press the PRINT switch to make a copy with the new setup.
The greater the setup value is, the darker the copy is, and vise versa. Only EXP.3 copy is made. If it is set to a darker density, EXP.1 
and EXP.5 copies also become darker. If it is set to a brighter density, they also become brighter.
When the CLEAR key is pressed, the entered setup value is saved and the simulation is terminated.
Any copy mode can be selected with the copy mode select key. The setup value of the selected copy mode is displayed on the copy 
quantity display.
(Setup range: 0 – 99)
18
Image contrast adjustment (300dpi)
Used to set the image contrast in each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading operations are performed and the current setup value is displayed in two digits. 
(Default: 50)
Change the setup value with the copy quantity keys. Press the PRINT switch and a copy is made according to the new setup. The 
greater the setup value is, the higher the contrast is. The smaller the setup value is, the lower the contrast is. Though only EXP.3 copy 
is made in this simulation, the contrast levels in EXP.1 and EXP.5 are also changed. Press the CLEAR key to save the setup and exit 
from the  simulation mode.
Use the copy mode select key to select a copy mode . The setup value of the selected copy mode is displayed on the copy quantity 
display.
(adjustment range: 0 – 99)
Main 
code
Sub 
code
Content
Copy mode
Display lamp
AE mode (300dpi)
AE mode lamp
TEXT mode (300dpi)
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT) (300dpi)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE) (300dpi)
AE mode lamp & PHOTO mode lamp
Copy mode
Display lamp
AE mode (600dpi)
AE mode lamp
TEXT mode (600dpi)
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT) (600dpi)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE) (600dpi)
AE mode lamp & PHOTO mode lamp
Copy mode
Display lamp
AE mode (300dpi)
AE mode lamp
TEXT mode (300dpi)
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT) (300dpi)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE) (300dpi)
AE mode lamp & PHOTO mode lamp
Page of 14
Display