Follow the installation procedure below to use the unit properly.
SETUP PROCEDURE
When using the unit for the first time, setup the unit following the procedure shown
below.
below.
*
1
The multi-bypass tray is only included with the AL-1457.
*
2
If you are only using the unit for copying, skip this step.
If the unit does not function properly during setup or use, or if a function
cannot be used, see "TROUBLESHOOTING THE UNIT" (p.59).
cannot be used, see "TROUBLESHOOTING THE UNIT" (p.59).
1 Open the package, and make sure that all the accessories are
supplied with the unit. (p.8)
2 Remove the protective materials. (p.9)
3 Install the TD cartridge. (p.10)
4 Load the paper in the paper tray (p.15) or the multi-bypass
tray*
1
.
(p.17)
5 Connect the power cord. (p.12)
8 Now, you can copy (p.46), print (p.33), or scan (p.35) your
document.
7 Connect the interface cable*
2
(p.45) and turn on the unit. (p.12)
6 Install the software.*
2
(p.19)
2
SETTING UP THE UNIT
8
CHECKING PACKED COMPONENTS AND
ACCESSORIES
ACCESSORIES
Open the carton and check if the following components and accessories are
included.
If anything is not included or is damaged, contact your authorised service
representative.
included.
If anything is not included or is damaged, contact your authorised service
representative.
PREPARING THE UNIT FOR INSTALLATION
1
Be sure to hold the handles on
both sides of the unit to unpack
the unit and carry it to the
installation location.
both sides of the unit to unpack
the unit and carry it to the
installation location.
Drum cartridge
(installed in unit)
Operation manual
Power cord
Software CD-ROM
TD cartridge
9
2
2
Remove all pieces of tape shown in the illustration below. Then
open the original cover/SPF and remove protective materials.
After that, take out the bag containing the power cord and TD
cartridge.
open the original cover/SPF and remove protective materials.
After that, take out the bag containing the power cord and TD
cartridge.
3
Release the scan head locking switch.
The scan head locking switch is under the original table.
If the switch is locked (
If the switch is locked (
)
, the unit will not operate. Unlock the switch (
)
as shown below.
AL-1217
AL-1457
Lock
Unlock
Grasp here and turn in
the direction of the arrow.
the direction of the arrow.
10
INSTALLING THE TD CARTRIDGE
1
Open the multi-bypass tray
(AL-1457, p.17), and then
open the side cover.
(AL-1457, p.17), and then
open the side cover.
2
Remove the CAUTION tape from the front cover and remove the
two protective pins from the fusing unit by pulling the strings
upward one at a time.
two protective pins from the fusing unit by pulling the strings
upward one at a time.
3
Push gently on both sides of the
front cover to open the cover.
front cover to open the cover.
4
Remove the TD cartridge from the bag. Remove the protective
paper. Hold the cartridge on both sides and shake it
horizontally four or five times. Hold the tab of the protective
cover and pull the tab to your side to remove the cover.
paper. Hold the cartridge on both sides and shake it
horizontally four or five times. Hold the tab of the protective
cover and pull the tab to your side to remove the cover.
CAUTION tape
Protective pins
4 or 5 times