DOWNLOAD Sharp AL-1000 / AL-1010 (serv.man13) Service Manual ↓ Size: 56.29 KB | Pages: 5 in PDF or view online for FREE

Model
AL-1000 AL-1010 (serv.man13)
Pages
5 Few pages! See other manuals at the bottom of the first or last page.
Size
56.29 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AL1000 User Programs
File
al-1000-al-1010-sm13.pdf
Date

Sharp AL-1000 / AL-1010 (serv.man13) Service Manual ▷ View online

[1] GENERAL
1.    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-1
2.    Target User Copy Volume . . . . . . . . . . . . . . . . . . . . . . . .  1-1
3.    Main features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-1
(1)    High-speed laser copying . . . . . . . . . . . . . . . . . . . .  1-1
(2)    High-quality digital image. . . . . . . . . . . . . . . . . . . . .  1-1
(3)    Substantial copying functions . . . . . . . . . . . . . . . . .  1-1
4.    Environmental
(1)    Normal operating condition . . . . . . . . . . . . . . . . . . .  1-1
(2)    Acceptable condition . . . . . . . . . . . . . . . . . . . . . . . .  1-1
(3)    Optional condition . . . . . . . . . . . . . . . . . . . . . . . . . .  1-1
(4)    Supply storage condition . . . . . . . . . . . . . . . . . . . . .  1-1
[2] SPECIFICATIONS
1.    Basic specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-1
2.    Operation specification . . . . . . . . . . . . . . . . . . . . . . . . . .  2-1
3.    Copy performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-3
4.    Others . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-4
[3] CONSUMABLE PARTS
1.    Supply system table . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-1
2.    Production control number (lot No.)identification. . . . . . .  3-1
[4] EXTERNAL VIEWS AND INTERNAL STRUCTURES
1.    Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-1
2.    Operation panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-2
3.    Internal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-3
4.    Motors and solenoids . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-4
5.    Sensors and switches . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-5
6.    PWB unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-6
7.    Cross sectional view . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-7
[5] UNPACKING AND INSTALLATION
1.    A WORD ON COPIER INSTALLATION . . . . . . . . . . . . .  5-1
2.    CHECKING PACKED COMPONENTS AND 
       ACCESSORIES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5-1
3.    UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5-2
4.    REMOVING PROTECTIVE PACKING MATERIAlS . . . .  5-2
5.    INSTALLING THE TD CARTRIDGE . . . . . . . . . . . . . . . .  5-2
6.    LOADING COPY PAPER (installing the paper tray) . . . .  5-3
7.    PLUGGING IN THE COPIER . . . . . . . . . . . . . . . . . . . . .  5-3
[6] PRINTING PROCESS
(1)    Functional diagram . . . . . . . . . . . . . . . . . . . . . . . . .  6-1
(2)    Outline of print process . . . . . . . . . . . . . . . . . . . . . .  6-2
(3)    Actual print process . . . . . . . . . . . . . . . . . . . . . . . . .  6-3
[7] OPERATIONAL DESCRIPTIONS
(1)    Outline of operation . . . . . . . . . . . . . . . . . . . . . . . . .  7-1
(2)    Scanner section . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7-2
(2)    Laser Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7-3
Fuser section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7-4
Paper feed section and paper transport section . . . . . . . . . . .  7-5
Process unit new drum detection mechanism . . . . . . . . . . . .  7-8
[8] DISASSEMBLY AND ASSEMBLY
1.    High voltage section . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-1
2.    Operation panel section. . . . . . . . . . . . . . . . . . . . . . . . . .  8-3
3.    Optical section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-3
4.    Fusing section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-5
5.    Tray paper feed/transport section . . . . . . . . . . . . . . . . . .  8-7
6.    Manual paper feed section. . . . . . . . . . . . . . . . . . . . . . .  8-12
7.    Rear frame section. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-16
8.    Power section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8-17
[9] ADJUSTMENTS
1.    Optical section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9-1
(1)    Image distortion adjustment . . . . . . . . . . . . . . . . . . .  9-1
(2)    Copy magnification ratio adjustment . . . . . . . . . . . .  9-4
(3)    Lens unit attachment reference . . . . . . . . . . . . . . . .  9-6
(4)    Image position adjustment . . . . . . . . . . . . . . . . . . . .  9-7
2.    Copy density adjustment . . . . . . . . . . . . . . . . . . . . . . . . .  9-8
(1)    Copy density adjustment timing . . . . . . . . . . . . . . . .  9-8
(2)    Note for copy density adjustment . . . . . . . . . . . . . . .  9-8
(3)    Necessary tool for copy density adjustment. . . . . . .  9-8
(4)    Features of copy density adjustment . . . . . . . . . . . .  9-9
(5)    Copy density adjustment procedure. . . . . . . . . . . . .  9-9
3.    High voltage adjustment . . . . . . . . . . . . . . . . . . . . . . . .  9-10
(1)    Main charger (Grid bias)
(2)    DV bias adjustment . . . . . . . . . . . . . . . . . . . . . . . .  9-10
[10] SIMULATION , TROUBLE CODES
1.    Entering the simulation mode . . . . . . . . . . . . . . . . . . . .  10-1
2.    List of simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10-2
3.    Contents of simulations . . . . . . . . . . . . . . . . . . . . . . . . .  10-3
4.    Trouble codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10-11
[11] USER PROGRAMS
Function which can be set with the user program. . . . . . . . .  11-1
Charge the setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11-1
[12] ELECTRICAL SECTION
1.    Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12-1
2.    Circuit descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12-3
A. Main PWB(MCU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12-3
(1)    CPU signal table . . . . . . . . . . . . . . . . . . . . . . . . . .  12-3
(2)    ASIC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12-6
(3)    Reset circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12-13
(4)    Heater lamp control circuit . . . . . . . . . . . . . . . . . .  12-14
(5)    Driver circuit (solenoid). . . . . . . . . . . . . . . . . . . . .  12-15
(6)    Toner supply motor drive circuit . . . . . . . . . . . . . .  12-15
(7)    Main motor drive circuit . . . . . . . . . . . . . . . . . . . .  12-15
(8)    Mirror motor circuit . . . . . . . . . . . . . . . . . . . . . . . .  12-16
(9)    Power circuit block diagram . . . . . . . . . . . . . . . . .  12-17
(10)    CI invertor PWB (circuit). . . . . . . . . . . . . . . . . . .  12-20
(11)    CCD PWB operational description . . . . . . . . . . .  12-20
Operation section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12-21
[13] CIRCUIT DIAGRAM
AC INTERLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13-1
MCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13-2
OPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13-8
POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13-9
ACTUAL WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . .  13-10
CONTENTS
AL-1000/1010
[11] USER PROGRAM
The conditions of factory setting can be changed according to the use conditions.
Functions which can be set with the user program
Function
Contents
Factory setting
Auto clear.
When a certain time is passed after completion of copying, this function returns to the
initial state automatically. The time to reach the initial state can be set in the range of
30 sec to 120 sec by the unit of 30 sec. This function can be disabled.
60 sec
Pre-heat.
When the copier is left unused with the power ON, the power consumption is
automatically reduced to about 40Wh/H (
 Note).
The time to start this function can be set in the range of 30 sec to 90 sec by the unit
of 30 sec. This function cannot be disabled.
90 sec
When this function is operated, the pre-heat lamp on the operation panel lights up.
To return to the initial state, press any key on the operation panel. (When the COPY
button is pressed, a copy is made after returning to the initial state.)
Auto shut off
passing time.
When the copier is left unused with the power ON, the power consumption is
automatically reduced to about 18Wh/H (
 Note). The time to start this function can be
set in the range of 2 min to 120 min.
5 min
When this function is operated, all the lamps except for the pre-heat lamp on the
operation panel turn off.
To return to the initial state, press the COPY button.
Stream feeding.
Only models with SPF.
Set
Auto shut off setting
Used to set or cancel this function.
Set
Note: The power consumption values in pre-heat and auto shut off may be varied depending on the use conditions.
Change the setting.
Example: Changing the time to operate the auto shut off func-
tion (Change from 60 sec to 90 sec)
1. Press the right and the left exposure adjustment
keys simultaneously to start setting.
Keep pressing the keys for five sec.
Display lamps (
 blink simultaneously and “-
-” is displayed on the copy quantity display.
2. Select the function code with the 10-digit key
(copy quantity set key).
The number of the selected function blinks on the digit of 10
on the copy quantity display.
For auto clear, select “1.”
For setting, refer to the following function codes.
Function name
Function code
Auto clear
1
Pre-heat
2
Auto shut off passing time
3
Stream feeding
4
Auto shut off setting
5
[Cancel] If a wrong code is entered, press the clear key and
enter the correct function code.
 SPF only
3. Press the COPY button.
The number blinking on the digit of 10 of the coyp quantity
display is lighted.
The number of the current set code blinks on the digit of 1.
4. Select the setting code with 1-digit key (copy
quantity set key).
To set to 90 sec, select “3.”
For setting, refer to the following set codes.
Function
name
Set code
Function
name
Set code
Function
name
Set code
Function
name
Set code
Function
name
Set code
Auto
clear
0 (Cancel)
Pre-heat
0 (30 sec)
Auto shut
off
0 (2 min)
Stream
feeding
0 (Cancel)
Auto shut
off setting
0 (Cancel)
1 (30 sec)
1 (60 sec)
1 (5 min) 
1 (Setting) 
1 (Setting) 
2 (60 sec) 
2 (90 sec)
2 (15 min)
3 (90 sec)
3 (30 min)
4 (120 sec)
4 (60 min)
5 (120 min)
 : Factory setting
The number of the selected set code blinks on the digit of 1
of the copy quantity display.
[Cancel] When a wrong number of the function code is set,
press the clear key and perform the procedure again
from 2.
5. Press the COPY button.
The number blinking on the digit of 1 of the copy quantity
display is lighted up. This means the setting is completed.
[Note] To set another function, press the clear key after com-
pletion of this operation and perform the procedure
from 2.
6. Press either one of exposure adjustment keys 
(     or     ) to complete the setting.
Display lamps (
) go off and the copy quan-
tity display returns to the normal state.
AL-1000/1010
11-1
[11] USER PROGRAM
The conditions of factory setting can be changed according to the use conditions.
Functions which can be set with the user program
Function
Contents
Factory setting
Auto clear.
When a certain time is passed after completion of copying, this function returns to the
initial state automatically. The time to reach the initial state can be set in the range of
30 sec to 120 sec by the unit of 30 sec. This function can be disabled.
60 sec
Pre-heat.
When the copier is left unused with the power ON, the power consumption is
automatically reduced to about 40Wh/H (
 Note).
The time to start this function can be set in the range of 30 sec to 90 sec by the unit
of 30 sec. This function cannot be disabled.
90 sec
When this function is operated, the pre-heat lamp on the operation panel lights up.
To return to the initial state, press any key on the operation panel. (When the COPY
button is pressed, a copy is made after returning to the initial state.)
Auto shut off
passing time.
When the copier is left unused with the power ON, the power consumption is
automatically reduced to about 18Wh/H (
 Note). The time to start this function can be
set in the range of 2 min to 120 min.
5 min
When this function is operated, all the lamps except for the pre-heat lamp on the
operation panel turn off.
To return to the initial state, press the COPY button.
Stream feeding.
Only models with SPF.
Set
Auto shut off setting
Used to set or cancel this function.
Set
Note: The power consumption values in pre-heat and auto shut off may be varied depending on the use conditions.
Change the setting.
Example: Changing the time to operate the auto shut off func-
tion (Change from 60 sec to 90 sec)
1. Press the right and the left exposure adjustment
keys simultaneously to start setting.
Keep pressing the keys for five sec.
Display lamps (
 blink simultaneously and “-
-” is displayed on the copy quantity display.
2. Select the function code with the 10-digit key
(copy quantity set key).
The number of the selected function blinks on the digit of 10
on the copy quantity display.
For auto clear, select “1.”
For setting, refer to the following function codes.
Function name
Function code
Auto clear
1
Pre-heat
2
Auto shut off passing time
3
Stream feeding
4
Auto shut off setting
5
[Cancel] If a wrong code is entered, press the clear key and
enter the correct function code.
 SPF only
3. Press the COPY button.
The number blinking on the digit of 10 of the coyp quantity
display is lighted.
The number of the current set code blinks on the digit of 1.
4. Select the setting code with 1-digit key (copy
quantity set key).
To set to 90 sec, select “3.”
For setting, refer to the following set codes.
Function
name
Set code
Function
name
Set code
Function
name
Set code
Function
name
Set code
Function
name
Set code
Auto
clear
0 (Cancel)
Pre-heat
0 (30 sec)
Auto shut
off
0 (2 min)
Stream
feeding
0 (Cancel)
Auto shut
off setting
0 (Cancel)
1 (30 sec)
1 (60 sec)
1 (5 min) 
1 (Setting) 
1 (Setting) 
2 (60 sec) 
2 (90 sec)
2 (15 min)
3 (90 sec)
3 (30 min)
4 (120 sec)
4 (60 min)
5 (120 min)
 : Factory setting
The number of the selected set code blinks on the digit of 1
of the copy quantity display.
[Cancel] When a wrong number of the function code is set,
press the clear key and perform the procedure again
from 2.
5. Press the COPY button.
The number blinking on the digit of 1 of the copy quantity
display is lighted up. This means the setting is completed.
[Note] To set another function, press the clear key after com-
pletion of this operation and perform the procedure
from 2.
6. Press either one of exposure adjustment keys 
(     or     ) to complete the setting.
Display lamps (
) go off and the copy quan-
tity display returns to the normal state.
AL-1000/1010
11-1
[11] USER PROGRAM
The conditions of factory setting can be changed according to the use conditions.
Functions which can be set with the user program
Function
Contents
Factory setting
Auto clear.
When a certain time is passed after completion of copying, this function returns to the
initial state automatically. The time to reach the initial state can be set in the range of
30 sec to 120 sec by the unit of 30 sec. This function can be disabled.
60 sec
Pre-heat.
When the copier is left unused with the power ON, the power consumption is
automatically reduced to about 40Wh/H (
 Note).
The time to start this function can be set in the range of 30 sec to 90 sec by the unit
of 30 sec. This function cannot be disabled.
90 sec
When this function is operated, the pre-heat lamp on the operation panel lights up.
To return to the initial state, press any key on the operation panel. (When the COPY
button is pressed, a copy is made after returning to the initial state.)
Auto shut off
passing time.
When the copier is left unused with the power ON, the power consumption is
automatically reduced to about 18Wh/H (
 Note). The time to start this function can be
set in the range of 2 min to 120 min.
5 min
When this function is operated, all the lamps except for the pre-heat lamp on the
operation panel turn off.
To return to the initial state, press the COPY button.
Stream feeding.
Only models with SPF.
Set
Auto shut off setting
Used to set or cancel this function.
Set
Note: The power consumption values in pre-heat and auto shut off may be varied depending on the use conditions.
Change the setting.
Example: Changing the time to operate the auto shut off func-
tion (Change from 60 sec to 90 sec)
1. Press the right and the left exposure adjustment
keys simultaneously to start setting.
Keep pressing the keys for five sec.
Display lamps (
 blink simultaneously and “-
-” is displayed on the copy quantity display.
2. Select the function code with the 10-digit key
(copy quantity set key).
The number of the selected function blinks on the digit of 10
on the copy quantity display.
For auto clear, select “1.”
For setting, refer to the following function codes.
Function name
Function code
Auto clear
1
Pre-heat
2
Auto shut off passing time
3
Stream feeding
4
Auto shut off setting
5
[Cancel] If a wrong code is entered, press the clear key and
enter the correct function code.
 SPF only
3. Press the COPY button.
The number blinking on the digit of 10 of the coyp quantity
display is lighted.
The number of the current set code blinks on the digit of 1.
4. Select the setting code with 1-digit key (copy
quantity set key).
To set to 90 sec, select “3.”
For setting, refer to the following set codes.
Function
name
Set code
Function
name
Set code
Function
name
Set code
Function
name
Set code
Function
name
Set code
Auto
clear
0 (Cancel)
Pre-heat
0 (30 sec)
Auto shut
off
0 (2 min)
Stream
feeding
0 (Cancel)
Auto shut
off setting
0 (Cancel)
1 (30 sec)
1 (60 sec)
1 (5 min) 
1 (Setting) 
1 (Setting) 
2 (60 sec) 
2 (90 sec)
2 (15 min)
3 (90 sec)
3 (30 min)
4 (120 sec)
4 (60 min)
5 (120 min)
 : Factory setting
The number of the selected set code blinks on the digit of 1
of the copy quantity display.
[Cancel] When a wrong number of the function code is set,
press the clear key and perform the procedure again
from 2.
5. Press the COPY button.
The number blinking on the digit of 1 of the copy quantity
display is lighted up. This means the setting is completed.
[Note] To set another function, press the clear key after com-
pletion of this operation and perform the procedure
from 2.
6. Press either one of exposure adjustment keys 
(     or     ) to complete the setting.
Display lamps (
) go off and the copy quan-
tity display returns to the normal state.
AL-1000/1010
11-1
Page of 5
Display

Sharp AL-1000 / AL-1010 (serv.man13) Service Manual ▷ Download