PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING 2 - 13
PICTURE menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
BRIGHT
VLMP(#)
WR
0~ 31
0~ 31
○
CONTRAST
CONT
WR
0 ~ 100
0 ~ 100
BLACK LEVEL
BLVL
WR
0 ~ 100
0 ~ 100
TINT (HDMI)
TINT
WR
0 ~ 100
0 ~ 100
COLORS (HDMI)
COLR
WR
0 ~ 100
0 ~ 100
COLOR
ADJUSTMENT
COLOR MODE
BMOD(#)
WR
0
0
STD
2
2
VIVID
3
3
sRGB (When the input mode is DVI-D,
D-SUB[RGB])
4
4
HIGH ILLUMINANCE
5
5
USB
WHITE
BALANCE
THRU
CTMP
WR
0
0
PRESET
1~ 18
1~ 18
From 1: approximately 3,000K to 15:
approximately 10,000K (500K steps)
16: approximately 5,600K, 17: approximately
9,300K, 18: approximately 3,200K
USER
99
99
GAMMA
GAMM
WR
0 ~ 2、5
0 ~ 2、5
0:1.8、1:2.2、2:2.4、5:2.0
RESET
ARST
W
2
-
AUDIO menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
TREBLE
AUTR
WR
0 ~ 100
0 ~ 100
○
BASS
AUBS
WR
0 ~ 100
0 ~ 100
RESET
ARST
W
3
-
: ‘14/September
PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING 2 - 14
SETUP menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
DATE/TIME SETTING
DATE
WR
AABBCCDDEE
AABBCCDDEE
AA: Year, BB: Month, CC: Day, DD: Hour, EE:
Minute
○
SCHEDULE
SH01 ~
SH03
WR
ABBCCDDEEF
GHIJKLMNO
ABBCCDDEEF
GHIJKLMNO
Schedule of a specified number
A : Schedule 0= Not effective, 1 = Effective
B : Power-on hour 00-23, 99 = Not effective
C : Power-on minute 00-59, 99 = Not effective
D : Power-off hour 00-23, 99 = Not effective
E : Power-off minute 00-59, 99 = Not effective
F : Input 0 = Not specified, 1 = DVI-D, 3 = HDMI, 4
= D-SUB,
5 = USB
G : EVERY DAY 0 = OFF, 1 = ON
H : EVERY WEEK 0 = OFF, 1 = ON
I-O : MON-SUN 0 = OFF, 1 = ON
LANGUAGE
LANG
WR
14
14
ENGLISH
1
1
DEUTSCH
2
2
FRANCAIS
3
3
ITALIANO
4
4
ESPANOL
5
5
РУССКИЙ
6
6
日本語
INPUT SELECT
HDMI
HDSL
WR
0~1
0~1
0:PC、1:AV
DVI-D
SLDS
WR
0~2
0~2
0:RGB、1:COMPONENT
2:VIDEO
AUDIO OPTION
SPEAKER
SELECT
SPSL
WR
0~1
0~1
0: OFF, 1: ON
AUDIO OUTPUT
AOUT
WR
0~ 31
0~ 31
ID SETTING
ID NO.SETTING
IDST
W
0~ 25
Sets the monitor’s ID number. (“0” means “no ID
number”.)
R
0~ 25
Returns the monitor’s ID number.
ID NO. SETTING
(ONCE)
IDSL
W
W
1~ 25
Sets a monitor ID number.
This ID number is only effective for the command
immediately after this command.
0
Clears the ID number if one has been designated.
ID NO. SETTING
(SUBSEQUENT)
IDLK
1~ 25
Sets a monitor ID number.
This ID number is effective for the next and all
subsequent commands after this command.
0
Clears the ID number if one has been designated.
MULTI
ENLARGE
ENLG
WR
0~1
0~1
0: OFF, 1: ON
ENLARGE MODE
EMHV
WR
11 ~ 55
11 ~ 55
1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”,
where m and n are the numbers of monitors
specified for the longest direction and the shortest
direction respectively.)
IMAGE POSITION
(M x N)
EPHV
WR
11 ~ 55
11 ~ 55
Specifies values in the order of IMAGE POSITION
IN LONGEST/ SHORTEST DIRECTION.
BEZEL ADJUST
BZCO
WR
0~1
0~1
0: OFF, 1: ON
ENLARGE/
IMAGE POSITION
SETTING
ESHV
WR
XXYY
XXYY
XX: ENLARGE MODE (Same as EMHV), YY:
IMAGE POSITION (Same as EPHV)
THERMAL SENSOR SETTING
STDR(#)
WR
0~1
0~1
0: LANDSCAPE, 1: PORTRAIT
: ‘14/September
PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING 2 - 15
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
STANDBY MODE
STBM
WR
0~1
0~1
0: STANDARD, 1: LOW POWER
○
OFF IF NO OPERATION
ATOF
WR
0~1
0~1
0: OFF, 1: ON
POWER ON DELAY
PWOD
WR
0~ 60
0~ 60
0: OFF, 1-60 seconds
AUTO INPUT CHANGE
AICO
WR
0~1
0~1
0: OFF, 1: ON
ADJUSTMENT
LOCK
MONITOR
BUTTONS
ALCM(#)
WR
0 ~ 1、3
0 ~ 1、3
0: UNLOCK, 1: LOCK ALL, 3: LOCK BUT POWER
REMOTE
CONTROL
ALCR(#)
WR
0~3
0~3
0: UNLOCK, 1: LOCK ALL, 2: LOCK EXCEPT
VOLUME, 3: LOCK EXCEPT POWER
LED
OFLD
WR
0~1
0~1
0: ON, 1: OFF
POWER MANAGEMENT
(HDMI, DVI-D, D-SUB[RGB])
PMNG
WR
0~1
0~1
0: OFF, 1: ON
POWER MANAGEMENT
(D-SUB[COMPONENT], D-SUB[VIDEO])
PMAV
WR
0~1
0~1
0: OFF, 1: ON
AUTO PLAY
WR
0~1
0~1
0: PHOTO, 1: MOVIE
ALL RESET
RSET
W
1
1: ALL RESET
Others
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
VOLUME
VOLM(#)
WR
0~ 31
0~ 31
○
MUTE
MUTE(#)
WR
0~1
0~1
0: OFF, 1: ON
-
INFORMATION
MODEL
INF1
R
Value
R
○
SERIAL NO
SRNO
R
Value
R
MAC ADDRESS
RMAC
R
Value
FIRM VERSION
FMVR
R
Value
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
1
Internal temperature abnormal has occurred and
the monitor is in standby mode
2
Internal temperature abnormal occurred (To delete
the information of temperature
abnormal, turn off the main power.)
3
Internal temperature abnormal has occurred and
backlight brightness is dimmed
4
Temperature sensor abnormal
TEMPERATURE ACQUISITION
ERRT
R
Value
Returns the temperature at the temperature
sensors in the following format.
[Sensor 1] [Sensor 2]
Indicates a temperature sensor abnormality when
“126” is returned.
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
R
0
No detectable error has occurred
1
Standby mode by POWER button
3
Standby mode by RS-232C or LAN
4
Input signal waiting mode by No Signal
6
Standby mode by abnormal temperature
8
Standby mode by SCHEDULE setting
20
Standby mode by OFF IF NO OPERATION setting
<MEMO>
• With some commands, the settings of an item are not continuous. In that case, the entered parameter will be set to the closest setting.
(Example) When the settings are “...45, 50, 55...” :
The entered parameter is “50”, “51”, or “52”, “50” is set.
The entered parameter is “53”, “54”, or “55”, “55” is set.
• With some commands, the number set in the menu screen may differ from the number of the parameter.
: ‘14/September
PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING 2 - 16
■Controlling the Monitor with a PC (LAN)
Your monitor can be connected to a LAN allowing you to control it from a PC on the LAN.
The connection requires a commercially available LAN cable (UTP cable, Category 5, straight through).
<MEMO>
• You must assign an IP address to the monitor by following the procedures in “Settings to connect to a LAN”. (See the description on the
right.)
• Your PC must be installed with Internet Explorer (version 7.0 or later).
- Version 7, 8, or 9 of Internet Explorer is recommended.
- Use Internet Explorer Version 10 in compatibility mode.
• To control the monitor via LAN, set STANDBY MODE to STANDARD.
• You cannot use RS-232C and LAN control simultaneously.
Click on the first or last page to see other PN-Y475 service manuals if exist.