About Air Flow
About Air Flow
・ Air flows from lower part to upper part of the monitor (from right to left in the illustration below).
・ Please do not disturb inhalation of cool air in order to satisfy the condition which mentioned in "Space securing
and temperature. (More than intake vent wind velocity 1m/s )
and temperature. (More than intake vent wind velocity 1m/s )
The cool air is inhaled (if the protection panel is equipped)
Protection panel etc.
Display screen surface
The cool air
is inhaled.
is inhaled.
Upper part
of the unit
(Fan)
Upper part
of the unit
(Fan)
Lower part
of the unit
Lower part
of the unit
Wall
Ventilation duct installed
Floor
8
Face-UP installation
PN-V601/V601A/PN-V602 Installation Manual for Multi Displays <Rev3.0> 2013/10
CONFIDENTIAL
The setting for the horizontal installation in the OSD menu is required, when displays are installed horizontally.
Face-down horizontal installation setting
1) Press [SIZE] key for approx. 5 seconds.
(and the character “F” appears in the upper left of the screen)
2) [ ][ ][ ][ ]
1) Hold for approx 5 sec. both [MENU] and [INPUT] at the same time.
(and the character “F” appears in the upper left of the screen)
2) [ ][ ][ ][ ]
1. How to call menu
CUSTOM SETTING
MONITOR LAYOUT
FACE DOWN
- Change [VERTICAL] to [FACE DOWN].
- After checking the display, turn off the main
power
Note)
- Change the setting to [VERTICAL] in order to
change from horizontal installation to vertical one.
change from horizontal installation to vertical one.
- Do not use other setting.
2. Setting of the face-down installation
- If using the remote control unit
- If using the monitor buttons on the rear panel,
OK ---- [MENU]
Setting of face-down horizontal installation
9
Face-down installation
PN-V601/V601A/PN-V602 Installation Manual for Multi Displays <Rev3.0> 2013/10
CONFIDENTIAL
Securing Space and Temperature Conditions
Display screen surface
Protection panel etc.
Secure space more than 10 cm
Ventilation duct installed
Fix the unit using VESA compliant holes.(toward the direction of yellow arrow)
Securing Space and Temperature Conditions
Secure space
more than 20 cm
more than 20 cm
-Please secure space more than 20 cm from wall and ceiling in order to flow air smoothly.
- It may be necessary to take measures in order for inner fan to exhaust air immediately (i.e. guide the air flow by duct).
- It is necessary to keep the surrounding temperature under 30C degree. In other words, the air conditioner system must
work efficiently. The temperature at the heat outlet of fan
- It may be necessary to take measures in order for inner fan to exhaust air immediately (i.e. guide the air flow by duct).
- It is necessary to keep the surrounding temperature under 30C degree. In other words, the air conditioner system must
work efficiently. The temperature at the heat outlet of fan
(upper side of the display: at the part of illustration below)
must be kept under 35C degree.
- If displays are overlaid with protection panel, the temperature of the space between display surface and protection panel
must be kept under 40C degree with cooling system. (More than wind velocity 1m/s )
- As the protection panel may transform and curves inward by heat depending on its material, it should be set and adjusted
- If displays are overlaid with protection panel, the temperature of the space between display surface and protection panel
must be kept under 40C degree with cooling system. (More than wind velocity 1m/s )
- As the protection panel may transform and curves inward by heat depending on its material, it should be set and adjusted
considering necessary space between display and protection panel based on the flexure of protection panel,
load from upper part, installation method, or the material of protection panel etc.
(Please be careful that protection panel must not touch the display surface even if it is curved.)
- Do not press the display surface and drop anything on the display surface.
- Please be careful not to nip cables between display and mounting bracket.
- Please be careful not to nip cables between display and mounting bracket.
★
★
Lower part of the unit
Upper part of the unit
Lower part of the unit
Upper part of the unit
Ceiling
Wall
Secure space
more than 20 cm
more than 20 cm
10
Face-down installation
PN-V601/V601A/PN-V602 Installation Manual for Multi Displays <Rev3.0> 2013/10
CONFIDENTIAL
About Air Flow
About Air Flow
・ Air flows from lower part to upper part of the monitor (from left to right in the illustration below).
・ Please do not disturb inhalation of cool air in order to satisfy the condition which mentioned in "Space securing
and temperature. (More than intake vent wind velocity 1m/s )
and temperature. (More than intake vent wind velocity 1m/s )
Protection panel etc.
Display screen surface
Ventilation duct installed
Wall
The cool air is inhaled (if the protection panel is equipped)
Lower part
of the unit
The cool air
is inhaled.
is inhaled.
Upper part
of the unit
(Fan)
Lower part
of the unit
Upper part
of the unit
(Fan)
Ceiling
Protection panel etc.
11
Face-down installation