PN-R603/R703 Installation Guidelines <Rev1.0> February 2013 
CONFIDENTIAL 
- If the temperature is too high  
Electronic component’s 
life time will be shortened or break down.  
-If the temperature on LCD surface is too high                 
 Monitors will break down or uniformity issue will occur 
- If the temperature is too low  Monitors will break down,  
will not launch or display issue will occur. 
The thermal influence 
Space requirement 
 Securing space at the Top/ Bottom/ Left/ Right/ Behind / 
Surface of display is necessary regardless of wall-hanging 
or stand type installation.  
Temperature control and clearance space conditions 
- Usable temperature range
  
   
 
→ 
0-40 
- Temperature of LCD surface   → 
Under 60 
 Please follow these requirements when setting the display. 
Refer to them and install the display according to its 
requirements. 
 
※: this range may change by requirements. 
 
Heat prevention unit 
(Apiste co.) 
Example of fan installation 
Precautions for temperature and clearance space 
The effectiveness of each measure differs depending on the 
environment. Please choose the best measure for respective 
environment as follow.  
- Adding a cooling fan(please use the filter and clean it 
regularly.) 
- Improve the ventilation by widening its space 
- Adding a heat exchanger 
this figures are without outer casing. 
If you install with outer casing, requirements are changed by size/location of vent 
hole, whether or not fan. 
Horizontal / Vertical installation 
Top 
20.0cm 
Bottom 
5.0cm 
Side 
5.0cm 
Behind 
0.7cm 
Surrounding 
temperature 
0℃ - 40℃ 
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013 
CONFIDENTIAL 
Countermeasure 
The effect of direct sunlight 
Precautions for the direct sunlight 
-Set a sun-shade to protect the display from ultraviolet and infrared rays. 
-The effect of the heat 
(Even though the environmental temperature is fairly low, the temperature of the area under direct sunlight could be high.) 
 
Monitor will break down or uniformity issue will occur. 
-The effect of ultraviolet rays 
 
LCD or color filter will deteriorate. 
Please set this monitor to avoid the direct sunlight. These conditions may cause failure and/or deterioration.
  
 
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013 
CONFIDENTIAL 
-If the anti-dust solutions are not being considered -> 
The dust will enter into the LCD panel through the gaps and will 
cause the distorted image (see example below), and will break 
down in the end. 
The effect of dust 
AS 
Countermeasure against dust  
-Create a completely sealed enclosure. 
-The completely sealed enclosure shut off dust so it is 
advantageous for installation in locations with excessive 
amounts of dust, outdoor, and  that may occur in salt. 
-You will need to be a combination of countermeasure against 
thermal, such as the heat exchanger and the air conditioner. 
Precautions for using anti-dust display 
(2)it may raise the internal temperature for a display when using the 
filter, because of raising the air resistance. 
Please reduce the air resistance by increasing the area of filter, etc. 
(3)when making the enclosure, it needs the caution whether the fan 
air-breathe or exhaust the air. 
Intake air fan: 
The pressure in the enclosure is higher than out of enclosure. 
Therefore, dust does not break in the housing. It is limited the size of 
intake vent. And it is difficult to suck in much air(when using in dusty 
area). 
Exhaust air fan: 
The pressure in the housing is lower than out of enclosure. 
Therefore, dust breaks in the housing. It has much size of intake 
vent. And it is easy to control  the temperature(when using in less 
dusty area and severe temperature requirements). 
※to keep the performance, please clean the filter regularly 
About dust 
-Fundamentally, LCD monitor is designed for indoor usage. 
-When it is being used outdoor, or at dusty places, such as 
railway station or close to the traffic, the solutions against dust 
must be considered. 
Intake air fan 
Exhaust air fan 
The dust enters into the LCD panel 
and causes the distorted  image. 
Precautions for dust 
Precautions for using the filter 
(1)it is possible to prolong the filter life by 
using two filter and exchanging the fine 
screen pre-filter. 
-when using the anti-dust display(enclosure), please remove 
the  
dust with filter. 
PN-R603/R703 Installation Guidelines <Rev1.0> February 2013 
CONFIDENTIAL 
-when attaching LCD panel to protection panel, the reflection 
occurs and the visibility comes down. 
-Regarding protecting the reflection non-glare, it is effective to 
use the non-glare protection panel. 
-Non glare coating has two methods. First method is AR coating 
which decreases the reflection rate with light. Second method is 
silica coating which decreases the reflection rate with scattered 
reflected light. 
-Silica coating is cheaper than AR coating. However, images 
easily defocus and view angle is narrow with Silica coating. 
Please check it before installation. 
-Generally, when decreasing the reflection rate, image quality 
comes down. Therefore, please select the suitable protection 
panel in each installing location. 
-the closer a distance from the protection panel to the LCD panel  
get the clear image. Indeed, LCD surface temperature raise. 
(Please keep 3 cm clearance to flow the air.) 
About reflection  
About dew condensation, water drops 
AR coating 
-Humidity condition for IDP 
 Range of humidity condition for IDP : From 20% to 80%(no 
condensation)
 
-Dew condensation and/or liquid drops will cause the 
breakdown of the circuit and/or LCD panel.                     
Please install LCD away from condensation and liquid drops. 
-the environment which has high possibility of condensation                             
The place where temperature is generally low but has 
frequent warm air flow.                                                                        
(Example : the place in front of the vents of radiators. When 
the radiator is turn on in a cold winter morning, condensation 
occurs.) 
-the environment which has high possibility of water drops                         
“Semi-outdoor” place where strong winded-rain(typhoon) 
could potentially reach the monitor. The place which is below 
the pipes inside the ceiling. (When installing in these places, 
countermeasures should be taken to avoid water drops to 
reach the monitors. For example, covering the LCD monitor 
with box. In such a case, consideration should be given for 
direction of vent.) 
Air-breathing 
from below 
Exhausting the 
air to back 
Precautions for reflection, dew condensation and water drops 
Page of 19
Display

Sharp PN-R703 Handy Guide ▷ Download

  • DOWNLOAD Sharp PN-R703 Service Manual ↓ Size: 928.53 KB | Pages: 19 in PDF or view online for FREE
  • Here you can View online or download the Handy Guide for the Sharp PN-R703 in PDF for free, which will help you to disassemble, recover, fix and repair Sharp PN-R703 Monitor. Information contained in Sharp PN-R703 Handy Guide (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.